Pump
3A5082G
31
Common Functional Summary Data entries are listed
below.
Technical Summary
The Technical Summary contains two types of data.
•
The first report only provides data compiled since
the Pump Summary was reset to present day (see
A6 - Clearing the Functional and Technical User
Summary).
This is very similar to the resettable trip odometer in
your car.
•
The second is a report that covers the cumulative
life of the pump from the first day it was put into
service to present day.
This is very similar to an odometer in your car.
The log file is stored as:
GRACO/{DMS_id}/{download date -
YYYYmmDD}/TECHSUM.CSV
Example: GRACO/00025/20100911/TECHSUM.CSV
Common Technical Summary Data entries are listed
below.
Number of Cycles
The number of lubrication cycles
the unit has started.
Total Run Hours
Total amount of hours the pump
has been in the ON mode of the
ON/OFF cycle.
Total Powered On Hours
Total number of hours that the
unit has been powered on.
Local Manual Run
The number of times the manual
run button was pressed.
Remote Manual Run
The number of times the remote
manual run button was pressed.
Average Run Time
The average amount of time per
lubrication cycle that the pump
has been running (MM:SS).
Average Duty Cycle
The average percentage of time
the unit has been pumping while
it has been powered on.
Max Duty Cycle
The highest percentage of time
for one lubrication cycle that the
unit has been pumping while it
has been powered on.
Total Low Level Faults
Total number of low level faults.
Total Other Faults
Faults other than low level or
sensor feedback.
Total Fault Hours
Number of hours the system has
been powered on in fault mode.
Total Low Level Warnings
Number of low level warning
conditions.
Total Other Warnings
All other warnings, including
temperature and motor current.
Average Input Board
Voltage (DC)
The average input voltage
measured by the internal circuit
board.
Peak Input Board Voltage
(DC)
The peak input voltage measured
by the internal circuit board.
Average Motor Current
The average motor current
measured by the unit.
Peak Motor Current
The peak motor current
measured by the unit.
Average Internal
Temperature
The average internal temperature
seen by the unit.
Peak Internal
Temperature
The peak internal temperature
seen by the unit.
Low Internal
Temperature
The lowest internal temperature
seen by the unit.