Models*

3A3995L

3

Models*

*Lubricant output for these models: 0.2 cc per outlet and per stroke

Model Series

Inlet

No. of 

Outlets

Indicator 

Included

24Z477

B

1/8 in. bspp

6

24Z478

B

1/8 in. bspp

8

24Z479

B

1/8 in. bspp

10

24Z480

B

1/8 in. bspp

12

24Z481

B

1/8 in. bspp

14

24Z482

B

1/8 in. bspp

16

24Z483

B

1/8 in. bspp

18

24Z484

B

1/8 in. bspp

20

24Z485

B

1/8 in. bspp

22

24Z486

B

1/8 in. npt

6

24Z487

B

1/8 in. npt

8

24Z488

B

1/8 in. npt

10

24Z489

B

1/8 in. npt

12

24Z490

B

1/8 in. npt

14

24Z491

B

1/8 in. npt

16

24Z492

B

1/8 in. npt

18

24Z493

B

1/8 in. npt

20

24Z494

B

1/8 in. npt

22

24Z495

B

1/8 in. bspp

6

24Z496

B

1/8 in. bspp

8

24Z497

B

1/8 in. bspp

10

24Z498

B

1/8 in. bspp

12

24Z499

B

1/8 in. bspp

14

24Z500

B

1/8 in. bspp

16

24Z501

B

1/8 in. bspp

18

24Z502

B

1/8 in. bspp

20

24Z503

B

1/8 in. bspp

22

24Z504

B

1/8 in. npt

6

24Z505

B

1/8 in. npt

8

24Z506

B

1/8 in. npt

10

24Z507

B

1/8 in. npt

12

24Z508

B

1/8 in. npt

14

24Z509

B

1/8 in. npt

16

24Z510

B

1/8 in. npt

18

24Z511

B

1/8 in. npt

20

24Z512

B

1/8 in. npt

22

Summary of Contents for 24Z477

Page 1: ...mum Operating Pressure See page 3 for model information including maximum working pressure and approvals Related Manuals Important Safety Instructions Read all warnings and instructions in this manual...

Page 2: ...aration Blockage 13 Recycling and Disposal 14 End of Product Life 14 Kits and Accessories 15 CSP Divider Block Inlet Fittings 15 CSP Divider Block Outlet Doubling Plug 15 CSP Divider Block Outlet Comb...

Page 3: ...8 in npt 8 24Z488 B 1 8 in npt 10 24Z489 B 1 8 in npt 12 24Z490 B 1 8 in npt 14 24Z491 B 1 8 in npt 16 24Z492 B 1 8 in npt 18 24Z493 B 1 8 in npt 20 24Z494 B 1 8 in npt 22 24Z495 B 1 8 in bspp 6 24Z49...

Page 4: ...essure or temperature rating of the lowest rated system component See Technical Specifications in all equipment manuals Use fluids and solvents that are compatible with equipment wetted parts See Tech...

Page 5: ...be diverted to the next outlet away from the inlet port When one or more outlets are plugged the output is a multiple of the standard output For example One outlet provides 0 012 cu in 0 2 cc of lubri...

Page 6: ...ring A system can be set up to use an electronic controller or to use a pump with a built in controller A micro limit proximity switch sensor can be installed to the cycle indicator on the CSP block a...

Page 7: ...into the adapter 2 Tighten the set screw to within 5 to 7 in lbs 6 to 8 N m 3 Mount the proximity switch assembly to the CSP valve For Series A CSP Valves torque to within 25 to 30 in lbs 2 8 to 3 4...

Page 8: ...8 3A3995L Wiring Instructions NOTICE The electrical ratings for the system must not be exceeded Overloading the switch can cause it to fail on the first cycle FIG 8 26C823 Flying Lead 26C822 M12 Conne...

Page 9: ...ed to the inlet port If the lubricant supply is interrupted when restarted the cycle continues from the point it previously stopped Each plunger must complete a full movement before the next plunger c...

Page 10: ...the left side of Plunger 1 pushing the plunger to the right 3 Plunger 1 opens delivering lubricant to Outlet 1 FIG 10 Sequence 2 1 Lubricant fills the left side of Plunger 2 pushing the plunger to th...

Page 11: ...plunger to the right 2 Plunger 3 opens delivering lubricant to Outlet 6 FIG 12 Sequence 4 1 Lubricant fills the right side of Plunger 1 pushing the plunger to the left 2 Plunger 1 opens delivering lub...

Page 12: ...nger to the left 2 Plunger 2 opens delivering lubricant to Outlet 3 FIG 14 Sequence 6 1 The final sequence completes the cycle Lubricant fills the right side of Plunger 3 2 Plunger 3 opens delivering...

Page 13: ...m of contamina tion is found in a valve cleaning that valve will only tem porarily solve contamination blockage problems The source of the contamination must be eliminated for sat isfactory service Th...

Page 14: ...the product s useful life dismantle and recycle it in a responsible manner Perform the Pressure Relief Procedure page 9 Drain and dispose of fluids according to applicable regulations Refer to the ma...

Page 15: ...3000 psi 20 68 MPa 206 8 bar 1 17T780 FITTING compression 6 mm x 1 8 npt male straight 3000 psi 20 68 MPa 206 8 bar 1 17T781 FITTING compression 6 mm x 1 8 npt male 90 3000 psi 20 68 MPa 206 8 bar 1...

Page 16: ...Kits and Accessories 16 3A3995L FIG 16...

Page 17: ...9 MPa 69 bar 1 17R567 FITTING push to connect 6 mm tube x 1 8 bspt male straight 1000 psi 6 9 MPa 69 bar 1 17R568 FITTING push to connect 6 mm tube x 1 8 bspt male 90 1000 psi 6 9 MPa 69 bar 1 17R569...

Page 18: ...mm OD high pressure hose Part No Description Qty 17L437 STUD 90 1 8 in hose x PTC fitting 1 17L438 STUD straight 1 8 in hose x PTC fit ting 1 17L647 SLEEVE hose 1 8 in ID 1 Part No Description Qty 17...

Page 19: ...hown in FIG 17 Dis card the nuts and plate after the stud welding is com plete Proximity Switch Kit Only available for CSP valves with an indicator pin Part No Description Qty 26A478 KIT weld stud 1 S...

Page 20: ...Dimensions 20 3A3995L Dimensions This dimension varies and is determined by the number of outlets See No of Outlets page 21 for this dimension...

Page 21: ...si 350 bar 35 MPa Inlet Connection Size 1 8 in bspp 1 8 in npt Outlet Connection Size M10 x 1 f Maximum Working Temperature 212 F 100 C No of Outlets L page 21 LENGTH 6 outlets 2 4 in 60 mm 8 outlets...

Page 22: ...n material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRA...

Reviews: