background image

Repair 

8

334852D

Repair

The reference numbers used in the following Repair 
instructions refer to the Parts, page 10
.

Battery Installation

1.

Relieve pressure.

 See pressure relief procedure 

included in your dispense valve instruction manual.

2.

Attach the disposable grounding wrist strap 
(included in the kit) to your wrist. Connect the adhe-
sive-backed copper foil at the other end of the strap 
to any convenient electrical ground, such as the 
grounding screw or metal case of a grounded elec-
trical outlet.

3.

Lift the bottom edge of the black cover (1) away from 
the meter (2), and pull the cover off. Remove and 
discard the screws (6) and the large o-ring (4). Dis-
pose of the screws and o-ring according to all stan-
dards for disposal. 

4.

Insert a small, flat screwdriver or similar tool 
between the battery and the positive terminal (bat-
tery retainer) in the electronic control to remove the 
battery as shown in F

IG

. 8.

5.

Insert the new battery with the negative side of the 
battery position to the bottom of the battery holder. 
Press the battery firmly down until the positive ter-
minal clips above the battery. See F

IG

. 9 (Battery 

Side View) to identify the negative and positive 
sides of the battery.

6.

Install the new large o-ring (4) over the lip on the top 
of the metering unit (2). Align the notch on the side 
of the electronic control (3) with the notch on the 
side of the metering unit (2). 

7.

Install new screws (6). Tighten the screws in a diag-
onal pattern to 3 in-lbs to 5 in-lbs (0.34 N.m to 0.57 
N.m) until a complete seal is obtained as shown in 
the DETAIL in F

IG

. 10, page 9.

8.

Install the cover so the rolled-in edges are parallel 
with the inlet fluid passage of the metering unit.

F

IG

. 8

F

IG

. 9

Battery Side View

Summary of Contents for 24V553

Page 1: ...heres or hazardous locations For professional use only Models 24V553 Measures in gallons quarts pints and liters Meter is factory set in quarts Calibrate after electronic module replacement 1500 psi 10 3 MPa 103 bar Maximum Working Pressure Important Safety Instructions Read all warnings and instructions in this manual Save these instructions ...

Page 2: ...ace worn or damaged parts immediately with genuine manufac turer s replacement parts only Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sure all equipment is rated and approved for the environment in which you are using it Use equipment only for its intended purpose Call your distributor for information Route hoses and cables...

Page 3: ...d installing an in line meter It is not an actual system design Contact your Graco representative for assistance in designing a system to suit your needs Key A In line meter B In line strainer C Shutoff valve D Pressure relief valve E Check valve F Bleed off valve drain valve G Bleed type master air valve FIG 1 A B C D E F G ...

Page 4: ...y running fluid through the meter FIG 2 NOTE The digital display on the meter goes blank after approximately two minutes of non use Function of TOTAL To see the accumulated total of fluid dispensed through the meter press the TOTAL key The meter can accu mulate a running total of up to 19 999 units dispensed before returning to zero FIG 3 Function of RESET Press the RESET key to clear the quantity...

Page 5: ... instructions in the following section of this manual Calibration Mode The meter has a preset calibration factor from the factory From the CAL screen NOTE Instructions for displaying the CAL screen are provided in Setup Mode steps 1 5 1 To save the current Calibration factor press RESET and the unit will save and exit setup 2 To recalibrate the meter a Dispense 1 Quart or 1 Liter of fluid into a c...

Page 6: ...the lowest possible set ting for dispensing fluid 3 Put the tip of the nozzle at the bottom of the cali brated container 4 If the tip of the dispense valve does not reach the bottom of the calibrated container use a length of plastic tubing over the tip of the nozzle to ensure liq uid enters the container from the bottom 5 Trigger the gun slowly so the fluid immediately cov ers the tip of the disp...

Page 7: ... Cause Solution Digital display is dim Battery in electronic control is worn out Replace battery See page 8 Electronic control is malfunctioning Replace the electronic control Order Part No 24V554 Digital display does not activate Battery in electronic control is worn out Replace battery See page 8 Electronic control is malfunctioning Replace the electronic control Order Part No 24V554 There is no...

Page 8: ...screwdriver or similar tool between the battery and the positive terminal bat tery retainer in the electronic control to remove the battery as shown in FIG 8 5 Insert the new battery with the negative side of the battery position to the bottom of the battery holder Press the battery firmly down until the positive ter minal clips above the battery See FIG 9 Battery Side View to identify the negativ...

Page 9: ...he cover off Remove and discard the screws 6 Lift off the electronic control 3 Remove and discard the large o ring 4 screws and electronic control according to all standards for disposal 4 Install the new large o ring 4 over the lip on the top of the metering unit 2 Align the notch on the side of the new electronic control module 3 with the notch on the side of the metering unit 2 5 Install new sc...

Page 10: ...cluded in Kit 24V554 This kit also includes a disposable grounding strap not shown Underside view 1 6 3 4 2 7 Ref Part Description Qty 1 191782 GUARD impact 1 2 METERING UNIT gal lon quart pint liter 1 3 24V554 KIT electronic control 1 4 109137 O RING 1 6 112093 SCREW 6 7 BATTERY ...

Page 11: ...ressure Loss Tested in 10W oil at 70 F 21 C Flow rate varies with fluid pres sure temperature viscosity 150 psi 12 gpm 1 03 MPa 10 3 bar 45 4 lpm Weight 1 9 lb 0 95 kg Units of measurement Factory set in quarts Display shows quantity in 0 01 incre ments up to 199 99 gallons quarts pints or liters Total dis plays up to 19 999 units Inlet and outlet 1 2 npt non directional flow Operating temperature...

Page 12: ...not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation Disclaimers and Limitations The terms of this warranty constitute purchaser s sole and exclusive remedy and are in lieu of any other warranties express or implied including warranty of merchantability or warranty of fitness for a parti...

Reviews: