Electrical Schematics
Air Compressor Junction Boxes
24U078
24U080
WHT
BLK
GRN
WHT
BLK
GRN
WHT
BLK
RED
24U079
WHT
BLK
GRN
24U076
GR
OUND
STUD
WHT
BLK
16X011
A
C-O
T1
A
C-O
T2
BLK 5
BLU 1
RED 8
YEL 4
A
C
-W1-W5
A
C
-W4-W8
A
C
-GND
SS-1
SS-3
SS-2
SS-4
PD-GND2
PD-GND2
PD-CB6-2
PD-CB6-4
PD-CB8-4
PD-N
GND2
GR
OUND B
A
R
122313
CB01
CB02
CB03
CB04
CB05
CB06
CB07
CB08
5A
15A
15A
30A
20A
40A
20A
15A
CORD GRIP
121171
CORD GRIP
16M826
CORD GRIP
16M826
CORD GRIP
260067
117625
CORD GRIP
260067
117625
CABLE 24U078
T
O
MO
T
OR ST
AR
TER
CABLE 24U080
T
O
MO
T
OR ST
AR
TER
CABLE 24U079
T
O
MO
T
OR ST
AR
TER
CABLE 16X011
T
O
MO
T
OR ST
AR
TER
CABLE 24U076
T
O
MO
T
OR ST
AR
TER
MO
T
OR JUNCTION BO
X
AIR COMPRESSOR O
V
ER
TEMPERA
TURE BO
X
AIR COMPRESSOR ST
AR
T ST
OP BO
X
ELECTRICAL
ENCLOSURE
BREAKER DIN RAIL
24T061
WIRE NUT
#6
ST
OP
SWITCH
ST
AR
T
SWITCH
OV
E
R
TEMPERA
TURE
SENSOR
16Y809
127581
NEUTRAL
WIRE NUT
#6
ti23220a
8
Strip all wires to 3/4 in. ( x mm). Twist wires
together. Attach wire nuts (40) and wrap wire nut
with electrical tape so that the wire nut will not
come loose.
9
Remove cover from compressor. Insert wires
from starter box through strain relief. Connect as
shown and reassemble cover.