Connect Cables
7. Use a screw driver to punch out two 3/4 in.
knockouts. Install cord grips (23) at bottom hole
and (43) in upper hole.
ELECTRICAL ENCLOSURE
TI23260a
Figure 6
8. Loosen the nut on the cord grips (23, 43). Insert
power cable (128) through lower cord grip (23)
and cable (131) through upper cord grip (43).
9. Connect the black and white wire from cable
(128) to CB06 and the green wire to the ground
bus bar GB02 inside the electrical enclosure.
24U078
24U080
WHT
BLK
GRN
WHT
BLK
GRN
PD-GND2
PD-GND2
PD-CB6-2
PD-CB6-4
PD-CB8-4
PD-N
GND2
GROUND BAR
122313
CB05
CB06
CB07
CB08
20A
40A
20A
15A
CORD GRIP
121171
CORD GRIP
16M826
CABLE 24U078
TO MOTOR STARTER
CABLE 24U080
TO MOTOR STARTER
ELECTRICAL
ENCLOSURE
NEUTRAL
ti23263a
Figure 7 Electrical Enclosure
10. Connect cable (131) black wire to CB08 and
white wire to Neutral. Connect the green wire to
the ground bus bar, GB02 inside the electrical
enclosure. See Fig. 7.
11. Tighten nut on the cord grips (23, 43).
12. Route all cables along proper routes. See
Cable Routing, page 11
. Use wire ties (42) to
hold against frames.
13. Turn CB06 and CB08 on.
14. Turn on the 120/240 VAC alternator circuit
breaker (CB10).
Figure 8
332733A
5
All manuals and user guides at all-guides.com