Operation
8
3A1335K
6.
The thermal relief feature of this oil pump can
increase the amount of time needed to fully prime
the pump when compared to pumps without a ther-
mal relief feature. To minimize this effect, prime the
pump
before
connecting it to an already primed dis-
tribution system.
7.
Read and follow the instructions supplied with each
component in your system.
Startup
1.
Turn air supply on. Pump will pressurize the system.
2.
Trigger dispense valve to control the pump’s on/off
operation.
3.
When shutting off the system and before checking
or servicing,
relieve pressure
following pressure
relief procedure, page 7.
NOTICE
Never allow the pump to run dry of the fluid being
pumped. A dry pump will quickly accelerate to a high
speed, possibly damaging itself. If your pump acceler-
ates quickly, or is running too fast, stop it immediately
and check the fluid supply. If the supply container is
empty and air has been pumped into the lines, prime
the pump and lines with fluid, or flush it and leave it
filled with a compatible solvent. Be sure to eliminate
all air from the fluid system.
NOTE:
A pump runaway valve can be installed on the
air line to automatically shut off the pump if it starts to
run too fast.