Installation 

8

3A1318B

Connect the Fluid Lines

Connect a 1 to 3 ft (0.3-0.9 m) hose (E) to the ball valve 
(5) at the outlet of the fluid filter (4), to isolate the pump 
module from the main fluid line. Connect the other end 
of the hose to the main fluid line (F).

Connect the fluid return line (G) to the ball valve (14) at 
the inlet of the back pressure regulator (12). The return 
hose (18) connects the back pressure regulator to the 
3-way recirculation valve (46). As an option, the return 
hose may be connected to the return line fitting (155) on 
the drum cover (114); see page 18.

Connect the Air Line

Connect the main air supply line (A) to the tee (11k) of 
the air filter/regulator/lubricator assembly (11).

Supplied Components

The red–handled bleed–type master air valve 
(11h)

 is required in your system to relieve air 

trapped between it and the air motor when the valve 
is closed. Be sure the bleed valve is easily accessi-
ble from the pump, and is located 

downstream

 

from the pump air filter/regulator (11a).

The

 

pump air filter/regulator (11a)

 controls pump 

speed and outlet pressure by adjusting the air pres-
sure to the pump. It includes an air filter with a 40 
micron polypropylene element, to remove harmful 
dirt and moisture from the compressed air supply. 
Locate close to the pump, but 

upstream

 from the 

bleed–type master air valve (11h).

The air line lubricator (11b)

 provides automatic 

lubrication of the air motor.

The air relief valve (11j)

 opens automatically to 

prevent overpressurization of the pump.

Fluid is supplied to the pump through the

 suction 

hose (8) and tube (54 or 109). 

On Circulation 

Package 24H316, 

the tube (109) is installed in the 

shaft of the agitator (102). See F

IG

. 2.

The fluid filter (4) 

includes a 60 mesh (250 micron) 

stainless steel element to filter particles from the 
fluid as it leaves the pump. 

The fluid drain valve (D),

 is mounted in the bottom 

of the fluid filter bowl, and is required in your system 
to relieve fluid pressure in the hose and gun.

The back pressure regulator (12) 

controls back 

pressure to the gun and maintains proper circulation 
pressure.

The back–geared agitator (102)

 keeps the fluid in 

suspension and also includes a suction tube (109) 
to draw fluid from a 55 gallon drum. 

Included with 

Circulation Package 24H316 only.

The air–operated elevator (150)

 allows you to 

raise the drum cover and agitator from an empty 
drum, replace the drum, and lower the agitator into 
the new drum. 

Included with Circulation Package 

24H316 only.

Conversion Modules

Supply Module 239857

NOTE: 

Module 239857 is included in Circulation 

Package 24H316, with Agitator. Refer to page 7 for 
installation instructions.

Part No. 239857 Supply Module is available to convert a 
circulation pump module to a circulation package with 
agitator. The supply module includes an elevator, 
stainless steel drum cover, back–geared agitator with 
suction tube, and connecting hardware. Instructions are 
included, Manual 308769.

Heater Modules 239850 (120V), 239851 
(240V), and 239852 (220/240V)

Three Heater Modules are available to convert a 
circulation pump module or a circulation package with 
agitator to a heated system. Each module includes a 
heater configured to the desired voltage, and mounting 
hardware. Instructions are included, Manual 308771.

Summary of Contents for 24H313

Page 1: ...ng Pressure 100 psi 0 7 MPa 6 9 bar Maximum Air Inlet Pressure See page 3 for model information including approvals Important Safety Instructions Read all warnings and instructions in this manual Save...

Page 2: ...8 Connect the Air Line 8 Supplied Components 8 Conversion Modules 8 Grounding 10 Operation 11 Pressure Relief Procedure 11 Flush the Pump Before First Use 11 Starting and Adjusting the Pump 11 Elevat...

Page 3: ...si MPa bar Maximum Air Inlet Pressure psi MPa bar 24H313 A Stainless steel pump with wall bracket air controls back pressure regulator and stainless steel fluid filter 1 1 100 0 7 6 9 100 0 7 6 9 24H3...

Page 4: ...uipment until you identify and correct the problem Keep a working fire extinguisher in the work area Route exhaust away from all ignition sources If diaphragm ruptures fluid may be exhausted with air...

Page 5: ...and serious injury Open a valve to relieve the fluid expansion during heating Replace hoses proactively at regular intervals based on your operating conditions TOXIC FLUID OR FUMES HAZARD Toxic fluids...

Page 6: ...and plumbing NOTE Refer to FIG 2 on page 9 and to Dimensions page 24 and Mounting Hole Layout page 25 1 Position the bracket mounting plate 34 on the wall so the edge with the hook is facing up Mount...

Page 7: ...not used 3 Locate the elevator so the pump module s suction hose 8 will reach the swivel 101 at the top of the agitator 102 The suction hose is 6 ft 1 8 m long Do not stretch the hose tight let it ha...

Page 8: ...the pump through the suction hose 8 and tube 54 or 109 On Circulation Package 24H316 the tube 109 is installed in the shaft of the agitator 102 See FIG 2 The fluid filter 4 includes a 60 mesh 250 mic...

Page 9: ...8 m overhead clearance for the elevator when fully raised 1 Mount the pump module so the top of the bracket is 4 to 5 ft 1 2 to 1 5 m above the floor 2 The suction hose is 6 ft 1 8 m long Do not stre...

Page 10: ...p to a true earth ground 6 Suction hose Attach the hose 8 ground wire to the ground lug on the agitator If you are not using an agitator attach the wire to the fluid supply con tainer 7 Fluid supply c...

Page 11: ...nlet pressure to the pump is more than 25 of the outlet working pressure the ball check valves will not close fast enough resulting in inefficient pump operation 3 Open the back pressure regulator 12...

Page 12: ...306287 for further elevator operat ing instructions Agitator Operation 1 Close the agitator s needle valve L 2 Connect the quick coupler 124 on the end of the coiled hose 105 to the male fitting M on...

Page 13: ...on 3A1318B 13 FIG 5 Important Operation Components 4 D 46 43 8 125 114 150 105 18 11A 11h 12 14 124 M L K J 102 Items 12 and 14 are partially hidden 1 24H316 Circulation Package with Agitator Shown 1...

Page 14: ...gun manual 3 Remove the filter element from the fluid filter 4 Reinstall the filter bowl 4 Open the back pressure regulator 12 Set the 3 way recirculation valve 46 to the circulation posi tion 5 Place...

Page 15: ...d manifold fasteners 100 in lb 11 3 N m Retorque the air valve fasteners V in a crisscross pat tern to specified torque Center section 80 in lb 9 0 N m Air Filter Service Repair Kits are available Ref...

Page 16: ...or Kit parts are marked with a symbol 211 Individual parts are not available separately FIG 7 Air Filter 201 202 203 204 205 206 207 208 209 210 211 N P 1 1 1 1 1 1 1 ti05998a Lubricate with no 2 lith...

Page 17: ...Maintenance 3A1318B 17...

Page 18: ...arts 18 3A1318B Parts Part 24H316 Series A stainless steel circulation package with agitator ti7802c 159 Ref 105 Ref 159 105 124 104 103 101 150 107 100 108 155 Ref 155 125 109 Ref 102 Ref 114 134 102...

Page 19: ...n npt m x 3 4 npt f 1 104 500251 ELBOW 90 stainless steel 1 in npt 1 105 205600 HOSE air nylon 1 4 in 6 mm ID 1 4 npt mbe 50 ft 15 2 m long 1 107 114958 STRAP tie 3 108 222011 GROUND WIRE AND CLAMP 1...

Page 20: ...Part 24H314 Series A stainless steel circulation pump module 10 41 9 1 14 17 35 55 26 12 18 Ref 10 Ref 11g 11h 11k 11n 11j 2 19 4 21 51 5 3 15 53 50 7 13 22 34 32 44 45 46 48 43 47 18 20 8 11d 11c 11...

Page 21: ...1 11a AIR FILTER REGULATOR 113765 113765 1 11b LUBRICATOR 114005 114005 1 11c CONNECTOR quick 113763 113763 3 11d ADAPTER pipe 3 8 npt f 113767 113767 2 11e ELBOW 45 1 8 npt m x f 113630 113760 1 11f...

Page 22: ...6G820 6 40 NUT hex with nylon insert M5 x 0 8 105332 105332 6 41 GROUND WIRE AND CLAMP 237569 237569 1 42 TUBE nylon 1 4 in 6 mm ID 8 in 203 mm long Purchase locally 1 44 TEE sst 3 4 npt f run x 3 4 n...

Page 23: ...ir pressure curve 3 Follow left to scale to read fluid outlet pressure top chart or air consumption bottom chart 0 5 10 15 20 25 30 35 40 45 50 19 38 57 76 95 114 133 152 170 189 Fluid Flow gpm lpm 20...

Page 24: ...or when fully raised 1 Mount the pump module so the top of the bracket is 4 to 5 ft 1 2 to 1 5 m above the floor 2 The suction hose is 6 ft 1 8 m long Do not stretch the hose tight let it hang as show...

Page 25: ...before bolting it to the wall 1 Mount the pump module so the top of the bracket is 4 to 5 ft 1 2 to 1 5 m above the floor 2 4 0 in 101 6 mm 10 in 254 mm 1 0 in 25 4 mm 5 0 in 127 mm 1 2 5 5 in 140 mm...

Page 26: ...Mounting Hole Layout 26 3A1318B...

Page 27: ...1 Maximum operating temperature 150 F 66 C Sound Power at 100 psi 0 7 MPa 7 0 bar and full flow 90 dBa Sound Pressure at 70 psi 0 48 MPa 4 8 bar and 50 cpm at 100 psi 0 7 MPa 7 0 bar and full flow 84...

Page 28: ...rkmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR...

Reviews: