Part 24H313, Series A, stainless steel circulation pump module (with fluid filter)
Part 24H314, Series A, stainless steel circulation pump module

Ref. Description

Module

Qty

24H313 24H314 

1

PUMP, Husky 1050; 1:1 ratio; sst; 

see 

manual 312877

651000

651000

1

2

BUSHING; sst; 1 in. x 1/2 npt

513299

1

NIPPLE; sst; 1 in. x 3/4 npt

171439

1

3

TEE; sst; 3/8 npt(m) x 3/8 npt(f) run; 3/8 npt(f) 
branch

108673

1

4

FLUID FILTER; sst; 

see manual 307273

239853

1

FLUID FILTER; sst; 

see manual 308918

244053

1

5

VALVE, ball; sst; 1/4 npt(m) x 3/8 npsm(m); 

see manual 307068

237529

1

VALVE, ball; sst; 3/8 npt(m) x 3/8 npsm(m); 

see manual 307068

237533

1

6

NIPPLE; sst; 1/2 npt x 3/8 npt

111874

1

7

BUSHING; sst; 1 in. npt(m) x 3/4 npt(f)

502851

502851

1

8

HOSE, suction; nylon; 3/4 npt(mbe) sst 
couplings; 1/2 in. (13 mm) ID;
6 ft (1.8 m) long

221171

221171

1

9

ELBOW, tube fitting, 90°; 1/2 npt(m) x 1/2 in. 
(13 mm) OD tube

114110

114110

1

10

HOSE; polyurethane; 0.328 in. (8 mm) ID; 20 
in. (508 mm) long

Purchase Locally

1

11

AIR FILTER/REGULATOR/LUBRICATOR; 

includes items 11a to 11n

239849

239849

1

11a

.AIR FILTER/REGULATOR

113765

113765

1

11b

.LUBRICATOR

114005

114005

1

11c

.CONNECTOR, quick

113763

113763

3

11d

.ADAPTER, pipe; 3/8 npt(f)

113767

113767

2

11e

.ELBOW, 45°; 1/8 npt (m x f)

113630

113760

1

11f

.GAUGE, air

113911

113911

1

11g

.ADAPTER, tube fitting; 1/2 npt(m) x 1/2 in. 
(13 mm) OD tube

114129

114129

1

11h

.VALVE, ball, bleed–type; 3/8 npt (m x f)

113333

113333

1

11j

.VALVE, relief; 110 psi (7.6 bar, 0.76 MPa)

113498

113498

1

11k

.TEE; 3/8 npt(f) run x 3/8 npt(m) branch

113777

113777

2

11m

.PLUG; 3/8 npt

101754

101754

1

11n

.ADAPTER; 3/8 npt(m) x 1/4 npt(f)

159841

159841

1

12

REGULATOR, back pressure; 

see manual 

308401

236770

236770

1

13

ELBOW, 90°; sst; 3/4 npt (m x f)

500263

500263

1

14

VALVE, ball; sst; 3/8 npt(fbe); 

see manual 

307068

237532

237532

1

15

BUSHING; sst; 3/4 npt(m) x 3/8 npt(f)

500352

1

17

SWIVEL, 90°; sst; 3/8 npt(m) x 3/8 npsm(f)

207123

207123

1

18

HOSE, fluid return; nylon; 3/8 npt(mbe) sst 
couplings; 1/4 in. (6 mm) ID;
6 ft (1.8 m) long

114198

114198

1

19

SWIVEL; 1/2 npt (m x f); sst

114190

1

SWIVEL; 3/4 npt (m x f); sst

112268

1

20

SWIVEL; 3/4 npt (m x f); sst

112268

112268

1

21

GAUGE, fluid pressure; sst; 0-300 psi (0-21 
bar, 0-2.1 MPa)

187876

1

22

NIPPLE; sst; 3/4 npt; 7 in. (178 mm) long

513507

513507

1

26

SCREW, cap, hex head; sst; 3/8-16 x 1 in. (25 
mm) long

102471

102471

6

Summary of Contents for 24H313

Page 1: ...ng Pressure 100 psi 0 7 MPa 6 9 bar Maximum Air Inlet Pressure See page 3 for model information including approvals Important Safety Instructions Read all warnings and instructions in this manual Save...

Page 2: ...8 Connect the Air Line 8 Supplied Components 8 Conversion Modules 8 Grounding 10 Operation 11 Pressure Relief Procedure 11 Flush the Pump Before First Use 11 Starting and Adjusting the Pump 11 Elevat...

Page 3: ...si MPa bar Maximum Air Inlet Pressure psi MPa bar 24H313 A Stainless steel pump with wall bracket air controls back pressure regulator and stainless steel fluid filter 1 1 100 0 7 6 9 100 0 7 6 9 24H3...

Page 4: ...uipment until you identify and correct the problem Keep a working fire extinguisher in the work area Route exhaust away from all ignition sources If diaphragm ruptures fluid may be exhausted with air...

Page 5: ...and serious injury Open a valve to relieve the fluid expansion during heating Replace hoses proactively at regular intervals based on your operating conditions TOXIC FLUID OR FUMES HAZARD Toxic fluids...

Page 6: ...and plumbing NOTE Refer to FIG 2 on page 9 and to Dimensions page 24 and Mounting Hole Layout page 25 1 Position the bracket mounting plate 34 on the wall so the edge with the hook is facing up Mount...

Page 7: ...not used 3 Locate the elevator so the pump module s suction hose 8 will reach the swivel 101 at the top of the agitator 102 The suction hose is 6 ft 1 8 m long Do not stretch the hose tight let it ha...

Page 8: ...the pump through the suction hose 8 and tube 54 or 109 On Circulation Package 24H316 the tube 109 is installed in the shaft of the agitator 102 See FIG 2 The fluid filter 4 includes a 60 mesh 250 mic...

Page 9: ...8 m overhead clearance for the elevator when fully raised 1 Mount the pump module so the top of the bracket is 4 to 5 ft 1 2 to 1 5 m above the floor 2 The suction hose is 6 ft 1 8 m long Do not stre...

Page 10: ...p to a true earth ground 6 Suction hose Attach the hose 8 ground wire to the ground lug on the agitator If you are not using an agitator attach the wire to the fluid supply con tainer 7 Fluid supply c...

Page 11: ...nlet pressure to the pump is more than 25 of the outlet working pressure the ball check valves will not close fast enough resulting in inefficient pump operation 3 Open the back pressure regulator 12...

Page 12: ...306287 for further elevator operat ing instructions Agitator Operation 1 Close the agitator s needle valve L 2 Connect the quick coupler 124 on the end of the coiled hose 105 to the male fitting M on...

Page 13: ...on 3A1318B 13 FIG 5 Important Operation Components 4 D 46 43 8 125 114 150 105 18 11A 11h 12 14 124 M L K J 102 Items 12 and 14 are partially hidden 1 24H316 Circulation Package with Agitator Shown 1...

Page 14: ...gun manual 3 Remove the filter element from the fluid filter 4 Reinstall the filter bowl 4 Open the back pressure regulator 12 Set the 3 way recirculation valve 46 to the circulation posi tion 5 Place...

Page 15: ...d manifold fasteners 100 in lb 11 3 N m Retorque the air valve fasteners V in a crisscross pat tern to specified torque Center section 80 in lb 9 0 N m Air Filter Service Repair Kits are available Ref...

Page 16: ...or Kit parts are marked with a symbol 211 Individual parts are not available separately FIG 7 Air Filter 201 202 203 204 205 206 207 208 209 210 211 N P 1 1 1 1 1 1 1 ti05998a Lubricate with no 2 lith...

Page 17: ...Maintenance 3A1318B 17...

Page 18: ...arts 18 3A1318B Parts Part 24H316 Series A stainless steel circulation package with agitator ti7802c 159 Ref 105 Ref 159 105 124 104 103 101 150 107 100 108 155 Ref 155 125 109 Ref 102 Ref 114 134 102...

Page 19: ...n npt m x 3 4 npt f 1 104 500251 ELBOW 90 stainless steel 1 in npt 1 105 205600 HOSE air nylon 1 4 in 6 mm ID 1 4 npt mbe 50 ft 15 2 m long 1 107 114958 STRAP tie 3 108 222011 GROUND WIRE AND CLAMP 1...

Page 20: ...Part 24H314 Series A stainless steel circulation pump module 10 41 9 1 14 17 35 55 26 12 18 Ref 10 Ref 11g 11h 11k 11n 11j 2 19 4 21 51 5 3 15 53 50 7 13 22 34 32 44 45 46 48 43 47 18 20 8 11d 11c 11...

Page 21: ...1 11a AIR FILTER REGULATOR 113765 113765 1 11b LUBRICATOR 114005 114005 1 11c CONNECTOR quick 113763 113763 3 11d ADAPTER pipe 3 8 npt f 113767 113767 2 11e ELBOW 45 1 8 npt m x f 113630 113760 1 11f...

Page 22: ...6G820 6 40 NUT hex with nylon insert M5 x 0 8 105332 105332 6 41 GROUND WIRE AND CLAMP 237569 237569 1 42 TUBE nylon 1 4 in 6 mm ID 8 in 203 mm long Purchase locally 1 44 TEE sst 3 4 npt f run x 3 4 n...

Page 23: ...ir pressure curve 3 Follow left to scale to read fluid outlet pressure top chart or air consumption bottom chart 0 5 10 15 20 25 30 35 40 45 50 19 38 57 76 95 114 133 152 170 189 Fluid Flow gpm lpm 20...

Page 24: ...or when fully raised 1 Mount the pump module so the top of the bracket is 4 to 5 ft 1 2 to 1 5 m above the floor 2 The suction hose is 6 ft 1 8 m long Do not stretch the hose tight let it hang as show...

Page 25: ...before bolting it to the wall 1 Mount the pump module so the top of the bracket is 4 to 5 ft 1 2 to 1 5 m above the floor 2 4 0 in 101 6 mm 10 in 254 mm 1 0 in 25 4 mm 5 0 in 127 mm 1 2 5 5 in 140 mm...

Page 26: ...Mounting Hole Layout 26 3A1318B...

Page 27: ...1 Maximum operating temperature 150 F 66 C Sound Power at 100 psi 0 7 MPa 7 0 bar and full flow 90 dBa Sound Pressure at 70 psi 0 48 MPa 4 8 bar and 50 cpm at 100 psi 0 7 MPa 7 0 bar and full flow 84...

Page 28: ...rkmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR...

Reviews: