background image

Operation 

6

309926C

Operation

1.

Turn on air supply.

2.

Turn T-handle adjusting screw clockwise on the tank 
pressure regulator, while pulling the gun trigger fully 
back to start material flow.

3.

Continue turning T-handle clockwise until desired 
material flow is achieved. To decrease pressure turn 
T-handle counter-clockwise to a lower setting. Then 
relieve pressure in tank by pulling the ring on the 
safety valve. 

4.

Atomization air for the spray gun can be adjusted 
using the air adjusting valve on the spray gun or at 
the air regulator assembly (Model 234415 only) on 
the pressure tank.

5.

Operate spray gun according to instructions 
accompanying gun.

Maintenance

Cleaning the Tank

1.

Turn off main air supply to tank.

2.

Follow 

Pressure Relief Procedure

, page 4.

3.

Turn T-handle adjusting screw on regulator, 
counter-clockwise until no spring tension is felt.

4.

Slowly loosen thumb screws, tip clamps back and 
tip tank lid to one side.

5.

Loosen spray gun air cap ring about three turns.

6.

Turn on air supply.

7.

Hold a cloth over air cap on gun and pull trigger. 
This forces material back through the hose, into the 
tank.

8.

Empty and clean tank and parts using a suitable 
solvent.

9.

Pour solvent into tank.

10. Replace lid and tighten thumb screws and clamps.

11. Turn T-handle on tank regulator clockwise while 

pulling gun trigger fully back and spray until clean 
solvent appears.

12. Repeat steps 1-3.

Decorative powder coating may be affected by 
solvent contact. Avoid prolonged exposure of 
solvents to powder coated areas. Tank has been 
zinc plated underneath the decorative coating for 
rust protection.

Summary of Contents for 234414

Page 1: ...ducing materials 80 psi 552 kPa 5 5 bar Maximum Fluid Pressure Air pressure loads that are higher than design loads or alterations to the pressure feed tank can result in tank rupture or explosion Mod...

Page 2: ...ous injury Do not exceed maximum working pressure or temperature rating of the lowest rated system compo nent See Technical Data in all equipment manuals Use fluids and solvents that are compatible wi...

Page 3: ...WARNING 309926C 3...

Page 4: ...in place by tightening lock nut using a 9 16 open end wrench 3 Install regulator U10004 by tightening swivel adapter nut U23040 onto nipple U09993 Position unit so gauge is facing the same direction...

Page 5: ...r hose to the air outlet fitting which is directly opposite air inlet fitting on tank pressure regulator 7 Connect material hose to fluid outlet fitting on top of tank lid WARNING A safety valve prote...

Page 6: ...n air supply to tank 2 Follow Pressure Relief Procedure page 4 3 Turn T handle adjusting screw on regulator counter clockwise until no spring tension is felt 4 Slowly loosen thumb screws tip clamps ba...

Page 7: ...Pressure creepage registered on gauge Dirty or worn valve seat in regulator Clean or replace valve seat Fluid or air leak at lid gasket Defective lid gasket or thumb screws not tight Replace or tight...

Page 8: ...ure 234415 234417 only U08220 GAUGE air pressure U10028 PLUG U23045 NIPPLE closed 1 4 in u07050 TANK LINERS not shown U10004 U23040 U23042 116643 U23002 U23007 U23001 or U23072 U23065 U23062 U23060 U1...

Page 9: ...Parts 309926C 9...

Page 10: ...manship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR I...