Note

WARNING

WARNING

 indicates a potentially hazardous situation 

which, if not avoided, could result in death or serious 
injury.

CAUTION

CAUTION

 indicates a potentially hazardous situation 

which, if not avoided, may result in property damage or 
destruction of equipment.

A note indicates additional helpful information.

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent 
fire and explosion:
  • Use equipment only in well ventilated area.
  • Eliminate all ignition sources, such as pilot lights, cigarettes, portable electric lamps, and plastic drop 

cloths (potential static arc).

  • Keep work area free of debris, including solvent, rags, and gasoline.
  • Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
  • Ground equipment and conductive objectives. See 

Grounding 

in your sprayer manual.

  • Use only grounded hoses.
  • Hold gun firmly to side of grounded pail when triggering into pail.
  • If there is static sparking or you feel a shock, 

stop operation immediately

. Do not use equipment 

until you identify and correct the problem.

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.
  • Do not exceed maximum working pressure or temperature rating of the lowest rated system compo-

nent. See 

Technical Data

 in all equipment manuals.

  • Use fluids and solvents that are compatible with equipment wetted parts. See 

Technical Data

 in all 

equipment manuals. Read fluid and solvent manufacturer’s warnings.

  • Check equipment daily. Repair or replace worn or damaged parts immediately.
  • Do not alter or modify equipment.
  • Use equipment only for its intended purpose. Call your Graco distributor for information.
  • For professional use only.
  • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
  • Comply with all applicable safety regulations.

TOXIC FLUID OR FUMES HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swal-
lowed.

Read MSDS’s to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

PERSONAL PROTECTIVE EQUIPMENT

You must wear appropriate protective equipment when operating, servicing, or when in the operating 
area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic 
fumes, burns, and hearing loss. This equipment includes but is not limited to:

Protective eye wear 

Gloves, clothing and respirator as recommended by the fluid and solvent manufacturer

Hearing protection

Summary of Contents for 234414

Page 1: ...ducing materials 80 psi 552 kPa 5 5 bar Maximum Fluid Pressure Air pressure loads that are higher than design loads or alterations to the pressure feed tank can result in tank rupture or explosion Mod...

Page 2: ...ous injury Do not exceed maximum working pressure or temperature rating of the lowest rated system compo nent See Technical Data in all equipment manuals Use fluids and solvents that are compatible wi...

Page 3: ...WARNING 309926C 3...

Page 4: ...in place by tightening lock nut using a 9 16 open end wrench 3 Install regulator U10004 by tightening swivel adapter nut U23040 onto nipple U09993 Position unit so gauge is facing the same direction...

Page 5: ...r hose to the air outlet fitting which is directly opposite air inlet fitting on tank pressure regulator 7 Connect material hose to fluid outlet fitting on top of tank lid WARNING A safety valve prote...

Page 6: ...n air supply to tank 2 Follow Pressure Relief Procedure page 4 3 Turn T handle adjusting screw on regulator counter clockwise until no spring tension is felt 4 Slowly loosen thumb screws tip clamps ba...

Page 7: ...Pressure creepage registered on gauge Dirty or worn valve seat in regulator Clean or replace valve seat Fluid or air leak at lid gasket Defective lid gasket or thumb screws not tight Replace or tight...

Page 8: ...ure 234415 234417 only U08220 GAUGE air pressure U10028 PLUG U23045 NIPPLE closed 1 4 in u07050 TANK LINERS not shown U10004 U23040 U23042 116643 U23002 U23007 U23001 or U23072 U23065 U23062 U23060 U1...

Page 9: ...Parts 309926C 9...

Page 10: ...manship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR I...