background image

Set-Up 

4

309926C

Set-Up

Pressure Relief Procedure

1.

Shut off air supply to the tank by closing air valve.

2.

Pull ring on safety valve until pressure bleeds down.

Material Preparation

Follow manufacturer’s directions for mixing and 
preparing material. 

Strain material using a fine mesh screen to prevent 
foreign matter from entering and clogging passageways.

Tank Assembly

1.

Install tank handle and lock nut by turning handle 
clockwise 4-5 turns. Position handle so it is parallel 
to safety valve branch tee. 

2.

Secure in place by tightening lock nut using a 9/16” 
open end wrench.

3.

Install regulator U10004 by tightening swivel 
adapter nut U23040 onto nipple U09993. Position 
unit so gauge is facing the same direction as safety 
valve ring. Use 11/16” open end wrench to tighten 
swivel adapter nut.

WARNING

Pressure tanks remain pressurized until pressure is 
manually relieved. To reduce the risk of serious injury 
from pressurized fluid or accidental spray from gun, 
always follow this procedure to relieve pressure in the 
tank:
  • Before you check or service any part of the spray 

system.

  • Before you loosen or remove the pressure tank 

cover or fill port.

  • Whenever you stop spraying.

Tank handle must be attached before installing 
regulator.

Summary of Contents for 234414

Page 1: ...ducing materials 80 psi 552 kPa 5 5 bar Maximum Fluid Pressure Air pressure loads that are higher than design loads or alterations to the pressure feed tank can result in tank rupture or explosion Mod...

Page 2: ...ous injury Do not exceed maximum working pressure or temperature rating of the lowest rated system compo nent See Technical Data in all equipment manuals Use fluids and solvents that are compatible wi...

Page 3: ...WARNING 309926C 3...

Page 4: ...in place by tightening lock nut using a 9 16 open end wrench 3 Install regulator U10004 by tightening swivel adapter nut U23040 onto nipple U09993 Position unit so gauge is facing the same direction...

Page 5: ...r hose to the air outlet fitting which is directly opposite air inlet fitting on tank pressure regulator 7 Connect material hose to fluid outlet fitting on top of tank lid WARNING A safety valve prote...

Page 6: ...n air supply to tank 2 Follow Pressure Relief Procedure page 4 3 Turn T handle adjusting screw on regulator counter clockwise until no spring tension is felt 4 Slowly loosen thumb screws tip clamps ba...

Page 7: ...Pressure creepage registered on gauge Dirty or worn valve seat in regulator Clean or replace valve seat Fluid or air leak at lid gasket Defective lid gasket or thumb screws not tight Replace or tight...

Page 8: ...ure 234415 234417 only U08220 GAUGE air pressure U10028 PLUG U23045 NIPPLE closed 1 4 in u07050 TANK LINERS not shown U10004 U23040 U23042 116643 U23002 U23007 U23001 or U23072 U23065 U23062 U23060 U1...

Page 9: ...Parts 309926C 9...

Page 10: ...manship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR I...