4
308655
Installation
The typical installation shown in Fig.1 is only a guide to
help you select and install a pump; it is not an actual
system design. Contact your Graco distributor for
assistance in designing a system to suit your needs.
Always mount the pump firmly to a bracket or a
tank cover. Never operate the pump while it is not
mounted. Such use could damage the pump and
fittings.
CAUTION
D
N
A
C
A
KEY
A
Bleed-type master air valve
(required, Part No. 107142)
B
Air line filter
C
Air regulator and gauge
D
Pump runaway valve
E
Air inlet
F
Ball valve
(for releasing collected moisture)
G
Pump
H
Drain valve
(required, Part No. 210658)
J
Dispensing valve
(model 222411 shown)
K
Thermal relief kit
(required, Part No. 240429)
L
Male quick-disconnect fitting
M
Female quick-disconnect coupler
N
Air line lubricator
P
Fluid hose
R
Electrically conductive air hose
(218093 shown)
Use at least 1/2 in. (13 mm) ID to supply an adequate volume
of air to the air motor.
S
Fluid inlet
T
Wall-mounting bracket
(Part No. 238245)
Y
Ground wire
(required, Part No. 222011)
Z
Muffler
Fig. 1
B
E
G
Y
H
P
J
L
M
DETAIL A
For Portable Applications
R
S
K
A
F
Z
06038
T
TI0890