17
308655
0
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
1400
0
1
2
3
4
5
6
FLUID FLOW––gpm (lpm)
Test Fluid: 10-weight oil at 75
_
F (23.9
_
C)
To find fluid outlet pressure
at a specific fluid flow
and operating air pressure:
1. Locate desired fluid flow along bottom of chart.
2. Follow vertical line up to intersection with
selected fluid outlet pressure curve (black).
3. Follow left to scale to read fluid outlet pressure.
To find pump air consumption
at a specific fluid
flow and air pressure:
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with selected
air consumption curve (gray).
2. Follow right to scale to read air consumption.
Air
Consumption
––scfm
(m
#
/min)
KEY
black curves=fluid outlet pressure
gray curves=air consumption
90
(2.52)
(96.6)
A
40 psi (2.8 bar) air pressure
B
70 psi (4.8 bar) air pressure
C
100 psi (6.9 bar) air pressure
D
150 psi (10.4 bar) air pressure
B
C
D
B
D
C
FLUID OUTLET PRESSURE––psi (bar)
A
(89.7)
(75.9)
(82.8)
(69.0)
(62.1)
(55.2)
(48.3)
(41.4)
(34.5)
(27.6)
(20.7)
(13.8)
(6.9)
(3.8)
(7.6)
(11.4)
(15.1)
(18.9)
(22.7)
80
(2.24)
70
(1.96)
60
(1.68)
50
(1.40)
40
(1.12)
30
(0.84)
20
(0.56)
10
(0.28)
A
Performance Chart