6
307-922
SETUP
SUCTION HOSE
PRIMING TUBE
INLET VALVE
MOTOR
ON/OFF SWITCH
POWER SUPPLY CORD
SPRAY VALVE
PRIMING VALVE
FILTER
25 FT. (7.6 M) HOSES
USE TWO WRENCHES
TO TIGHTEN
SPRING GUARD MUST BE
AT ROLLER VALVE INLET
TRIGGER
USE TWO WRENCHES
TO TIGHTEN
Fig 1
USE TWO WRENCHES
TO TIGHTEN
0335
0285
1. Remove all parts from the boxes and assemble them
as shown in Fig 1, following the notes on the drawing.
2. Prepare the material according to the manufactur-
er’s recommendations. Remove any skin that may
have formed on the top of the material. If necessary,
thin the material.
Never remove the third (grounding) pin of the power
supply cord. Be sure the outlet is properly grounded.
In the event of an electrical short circuit, grounding
reduces the risk of an electric shock by providing an
escape wire for the electric current.
Inspect the power supply cord and extension cord
before each use. Be sure they are in good condition
and have undamaged three-pin plugs. Replace im-
mediately if either cord shows signs of wear or
damage.
WARNING
3. Plug the power supply cord into a properly grounded,
120 V electrical outlet. See Fig 2. Do not use an
adapter. All extension cords must have three wires.
Use the chart below for selecting the appropriate
wire gauge for the extension cord.
Cord Length
Extension
feet
(meters)
Wire Gauge
1–100
(1–30)
18
100–200
(30–61)
16
200–300
(61–92)
14
over 300
(over 92)
12
Fig 2
0286
GROUNDED
OUTLET
GROUNDING PIN
Summary of Contents for 222-340