Setup
308950C
7
Setup
System Set-Up Menu
The System Set–Up Menu is used to configure the type of pump and automatic lubricating system that is connected
to the Lubrication Controller. The modes in the System Set–Up Menu progress in the order shown in the table below.
To access the System Set–Up Menu, press the UP and DOWN buttons simultaneously, and hold them down for two
seconds.
Time Menu
The Time Menu is used to adjust the Pump On cycle and Pause Interval. The modes in the Time Menu progress in
the order shown in the table below.
To access the Time Menu, press and hold the TIME button for two seconds.
AUTOMATIC SYSTEM ACTIVATION
Do not connect power to timer if the pump power
supply is on, unless activation of the automatic lubri-
cation system is intended. This device is an auto-
matic timing device that activates the output circuit
(air solenoid valve) upon power connection or upon
exit of the programming function. Ignoring this warn-
ing could lead to serious injury including fluid injec-
tion and amputation due to activation of connected
system components.
Parameter
Description
Screen Display
Operation
Lubrication system
type
Pressure–switch–controlled on
single–line systems
Press the UP button to toggle
between the two options.
No pressure–switch–control,
just timer
Press the TIME button to accept the change. Press the RESET button to cancel the change.
Parameter
Description
Screen Display
Operation
Pump On time
Indicates the minimum
Pump On time in
minutes : seconds
Maximum: 59:50
Minimum: 00:10
Pump ON light flashing
Press the UP and DOWN buttons
to adjust the setting.
Press and hold the TIME button for two seconds to advance to the next option.
Pause interval
Indicates the Pause Interval
between lubrication cycles in
hours : minutes
Maximum: 99:59
Minimum: 00:01
TIMER light flashing
Press the UP and DOWN buttons
to adjust the setting.
Press and hold the TIME button for two seconds to advance to the next option.
Summary of Contents for 115123
Page 11: ...Technical Data 308950C 11 ...