background image

Setup 

6

308950C

Setup

PUMP ON light: Indicates that the Lubrication Controller is in the Pump On mode, and the device (air solenoid valve) 
connected to terminals 4 and 6 should be receiving power.

Display: TIMER light on: Display indicates time remaining in hours and minutes until the next Pump On cycle.

PUMP ON light on: Display indicates time remaining in minutes and seconds in the Pump On cycle.
ALARM light on: Display indicates alarm codes (see page 8).
INDICATOR lights flashing: Display indicates that the Lubrication Controller is counting down to

the next Pump On cycle.

INDICATOR lights steady: Display indicates that the Lubrication Controller is in Suspended

mode, activated by contacts 14 and 15 being close–circuited.

TIMER light: Indicates that the Lubrication Controller is in Timer mode.

UP button: For toggling between options in the System Set–Up Menu. Press this button and the DOWN button at the 
same time to enter the System Set–Up Menu.

TIME button: For advancing to the next option in the Time Menu.

DOWN button: For adjusting settings in the Time Menu. Press this button and the UP button at the same time to 
enter the System Set–Up Menu.

POWER light: Indicates that power to the Lubrication Controller is on.

RESET button: For resetting an alarm malfunction. Resets to the start of a lube cycle -- pushing this button activates 
Lubrication Controller to open solenoid and start pump. Will activate a manual lube cycle and resets pause interval.

LOW LEVEL light: Indicates that the reservoir fluid level is low.

ALARM light: Indicates that an alarm is activated.

8858A

Pump ON light

Display

TIMER light

UP button

TIME button

DOWN button

POWER light

INDICATOR light

ALARM light

LOW LEVEL light

RESET button

Summary of Contents for 115123

Page 1: ...arameters are electronically stored in a System Set Up Menu and a Time Menu see page 7 which eliminates the need to set dip switches or jumpers Table of Contents Warnings 2 Installation 4 Setup 6 Operation 8 Alarm Codes 8 Troubleshooting 9 Accessories and Kits 9 Technical Data 10 Dimensions 10 Mounting Hole Layout 10 Graco Standard Warranty 12 Graco Information 12 Important Safety Instructions Rea...

Page 2: ...over Do not touch electrical components inside the Lubrication Controller you could get an electric shock or damage the circuits This equipment is for professional use only Read all instruction manuals tags and labels before operating the equipment Use the equipment only for its intended purpose If you are not sure call your Graco distributor Do not alter or modify this equipment Use only genuine ...

Page 3: ...egulator B3 Lubricator C Air solenoid valve D Pump module E Ignition switch G High pressure lubricant supply lines H Injector banks J Lubrication controller FIG 1 Typical Installation _____________________________________________________________________ A B1 B2 B3 C D G H H J 8853A E Low Reservoir Level Switch User Provided Pressure Switch For System Control Remote Alarm Device Light or Horn User ...

Page 4: ...eopening of the switch will resume Lubrication Controller function from the point at which operation was suspended 8 Connect the power leads from an isolated power supply Connect terminal 3 to the negative lead ground and connect terminal 2 to the positive lead 9 Replace the Lubrication Controller cover CAUTION This Lubrication Controller is not designed to be operated in a caustic environment CAU...

Page 5: ...0 volt power is not supported at this time 8855A 8854A See diagram below for terminal identification Optional circuit if using remote alarm Ignition Switch 24V Battery External Alarm 24V 1 Amp Max 24V Air Solenoid Black indicates not used Optional Devices Normally Open Pressure Switch Normally Open Fluid Level Switch Suspend Timer Device Ignition Switch Open Circuit Timer Functions Closed Circuit ...

Page 6: ...e Lubrication Controller is in Timer mode UP button For toggling between options in the System Set Up Menu Press this button and the DOWN button at the same time to enter the System Set Up Menu TIME button For advancing to the next option in the Time Menu DOWN button For adjusting settings in the Time Menu Press this button and the UP button at the same time to enter the System Set Up Menu POWER l...

Page 7: ... power connection or upon exit of the programming function Ignoring this warn ing could lead to serious injury including fluid injec tion and amputation due to activation of connected system components Parameter Description Screen Display Operation Lubrication system type Pressure switch controlled on single line systems Press the UP button to toggle between the two options No pressure switch cont...

Page 8: ...n auto matic timing device that activates the output circuit air solenoid valve upon power connection or upon exit of the programming function Ignoring this warn ing could lead to serious injury including fluid injec tion and amputation due to activation of connected system components Alarm Code Description Corrective Action A01 No parameters set Set the parameters of the system See Setup on page ...

Page 9: ... No power supplied to solenoid Solenoid faulty Timer faulty Low Level alarm Power light off timer is not receiving power Verify connections and verify power supply Power light on verify solenoid connections Replace solenoid Replace timer Refill reservoir Pressure switch fails to shut down system2 Pressure switch incorrectly wired Pressure switch faulty Timer faulty Verify proper connections Replac...

Page 10: ...n level optional Normally open level switch closes upon low level Outputs Air solenoid valve pump control 24V D C Alarm switch normally open optional Voltage free contact 250V maximum 1 amp Protection grade IP55 Nema 12 Operating temperature range 13 F to 131 F 25 C to 55 C 8852A 8852A 5 2 in 132 mm 5 2 in 132 mm 2 4 in 60 mm 8857A Drill four 0 14 in 3 5 mm holes 3 74 in 95 mm 3 74 in 95 mm ...

Page 11: ...Technical Data 308950C 11 ...

Page 12: ...anship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as se...

Reviews: