background image

Setup Mode Screen 4

View Adjust-Adjust-Adjust Screen Contrast

Note: Alarms Will Not Be Monitored, and Alarms Can Not 
Be Sent
 when in the the IrDA Transfer mode. 

Press both 

PWR side buttons simultaneously to exit the IrDA 

Transfer  mode.  Interrupting  an  IrDA  Transfer  in  progress 
may corrupt the internal SuperCell

TM

 name data base. If that  

occurs the internal SuperCell

TM

 name data base may need 

to be reloaded.

To program the Unit Identity enter the desired text into slot 
zero of the Messages section of the host program. 

4

The screen shows a series of bars representing the display 
contrast/viewing  angle.  Pressing  the  Up/Dwn  buttons  ad-
vances the bars by one, while */# advance the bars by ten, 
until they wrap back to zero. The viewing setting may need 
to  be  adjusted  if  the  unit  is  exposed  to  wide  temperature 
variations. 

Motion Sensing - Disable or Select Time to Alarm 

Setup Mode Screen 5-A 

Motion Sensing Option Disabled

Setup Mode Screen 5-B 

Pre-Alert Motion Sensing Time Setting

SC500  is  shipped  with  the  Motion Sensing option dis-
abled 
unless stipulated otherwise by the customer. The end 
user  may  select,  using  the 

Up/Dwn  buttons,  from  30,  45, 

60, 75, 90, 105 and 120 seconds to alarm after motion has 
ceased. Approximately 12 seconds before the SC500 goes 
into alarm a pre-alert is sounded. The 

pre-alert (a series of 

up tones) is sounded at 11, 8, 5 and 2 seconds if no motion 
is sensed. If no motion is sensed by the end of the pre-alert 
the unit goes into Alarm. 

When Motion Sensing is enabled the countdown timer rep-
resents the time to alarm. When motion is sensed the timer 
will reset to the alarm time selected. 

The Signal Lost Timer feature is to prevent users from un-
knowingly  wondering  out  of  range  of  the  base/mobile  sys-
tem.

The Signal Lost Timer option may only be used in con-
junction  with  other  compatible  Grace  Lone  Worker 
products, turning it ON without these products in range 
results  in  a  Signal  Lost  alert  message  frequently  ap-
pearing.  Simply disable this alert to prevent these mes-
sages.

The 

SC500 is shipped with the Signal Lost Timer option 

disabled or turned OFF unless stipulated otherwise by the 
customer. The end user may enable this feature by select-
ing from one to fifteen minutes, in one minute increments, 
to activate an alert on the SC500 when no signal has been 
received from the Base, Watchdog, or MX products, for the 
pre-selected time frame.

Setup Mode Screen 6

Current Countdown Screen

Current Time Setting Screen

Signal Lost Timer - Enabled or ON

Signal Lost Timer - Enabled or OFF

The display shows the current countdown first, followed by 
the current time setting, in minutes.  For example if three min-
utes is selected, and one whole minute has already passed, 
the display will show 1/3, to indicate that there is one full min-
ute remaining.  The last minute is counted down in seconds.  
The top status line shows the countdown progression.

Signal Lost 

Signal Lost Display Screen

Signal Lost Count Down Time Screen

The first time a 

Signal Loss happens, until a signal is (re)

acquired, Signal Lost is displayed on the screen, the Super-

Signal Lost 

Continued on Next Page

IrDA Transfer 

Continued

 

      AM16

Motion Sensing

     Disabled

UP=+15, Down=-15 Secs.

 

      AM16

Motion Sensing

  45 Seconds

    UP=+15, Down=-15 Secs.

 

      AM16

Signal Lost Timer

       Disabled

    UP=+1, Down=-1

 

 02       AM16

Signal Lost Timer

02/03 Minutes

          UP=+1, Down=-1 Mins.

 

 17       AM16

Signal Lost Timer

18 Seconds

          UP=+1, Down=-1 Mins.

 

          

  

02

       AM16

 

915 MHzV2.9 Fire

Motion Sensing
Disabled

OEM-9090

ID:DA-006

 

      AM16
   View Adjust

UP=+1,Down=-1,*=+10,#=-10

 

 00       AM16

 

          Out of Range

Signal Lost

Summary of Contents for SuperCell SC500

Page 1: ...represent the SC500 unit I D The bottom left line of the screen shows the radio frequency the radio firm ware revision and the type of firmware The SuperCellTM is turned OFF by simultaneously pressing both PWR buttons and holding for about three seconds or until the display shows the message Off This is accompa s e n o t o i d u a g n i p e e w s n w o d n e h t d n a p u s e i r e s a y b d e i n...

Page 2: ... Up Dwn buttons to chose the desired message Up and Down change the message count by one while and change the count by 16 Once a message is selected press and hold the Select button for approximately three seconds the message will be transmitted and a Message Sent acknowledgment will be displayed on the screen Use Up Dwn buttons to choose other messages or the Menu button to leave the Send Mes sag...

Page 3: ... audio beep and a message For more information on System Link Test see Mobile Lone Worker Applications later in User s Guide System Link Test Screen SC500 settings that are rarely changed are under the Setup Menu Press SELECT to enter the Setup Mode and press the Menu button to cycle through the ten SC500 setup screens To exit the Setup Mode reset the unit by simulta neously pressing and releasing...

Page 4: ...ent users from un knowingly wondering out of range of the base mobile sys tem The Signal Lost Timer option may only be used in con junction with other compatible Grace Lone Worker products turning it ON without these products in range results in a Signal Lost alert message frequently ap pearing Simply disable this alert to prevent these mes sages The SC500 is shipped with the Signal Lost Timer opt...

Page 5: ...led as described in the previous section the Alarm button will not make any local sound even if this setting is enabled As supplied from the factory pressing the Alarm button does NOT generate an Alarm sound Backlight Setup Mode Screen 10 Pressing the Select button will toggle the Backlight state be tween Enabled Disabled It may be desirable to disable the back light in covert operations or situat...

Page 6: ...t time System Test Screen The display will show the following when a Link Status mes sage is received in conjunction with a power up sound sequence System Test Successful Screen If no Link Status Acknowledgment message is received after five minutes this will be indicated via a simple audio beep and a message similar to the one below System Test Timed Out Screen Note The complete system path may c...

Page 7: ...ED and optional Audible Alert Optional audible tones for alarm alarm received call back and reset Check in Status Signal Periodically transmitted to LCD T3 SM2000 Command Bases Watchdog and many other Grace Telemetry products SuperCellTM SC500 SPECIFICATIONS AND FEATURES When a train is detected the Train Detector sends an Evacu ation Alarm signal to the SC500 The SC500 displays the EVACUATION mes...

Page 8: ...305 Bend Hill Road Fredonia PA16124 U S A 724 962 9231 www graceidustries com Grace Industries Inc Printed in U S A SuperCell 500 06 2011 UI ...

Reviews: