Low Battery Indication 

When approximately six hours of operating time remain in 
standby  mode,  the  SuperCell

TM

  will  display  a  plug  icon  on 

the display status screen. The power-on tones are not emit-
ted when SuperCell

TM

 has a low battery. Low battery is also 

indicated by the Operational Status LED changing to a peri-
odic Red strobe. A double chirp sounds once every five min-
utes  with  audio  enabled. 

Warning: There  are  no  audible 

low battery sounds with audio tones disabled. 

When  low  battery  is  indicated,  the  battery  should  be  re-
charged  as  approximately  three  hours  of  operating  time  
remain.  The  Rechargeable  lithium  battery  is  not  user  
replaceable.

With the charger provided, recharge time is approximately 
six  hours,  from  a  low  battery  warning,  and  nine  hours  for 
a  dead  battery.    Due  to  current  limits  imposed  by  Intrinsic 
Safety requirements, a unit that has gone completely dead 
will have to be removed from the charging base and rein-
serted when the charging light turns red.  Typical operation 
time  between  recharging  is  approximately  eighty  hours  in 
standby/ready mode.

SuperCell

TM 

Charging

Plug Charger into outlet. It takes about twenty seconds for 
the Green charger LED to come on. If it does not come on, 
or a Red LED comes on, it indicates the battery is to hot or 
cold, or has some other fault. 

Charging is completed when the green charge LED starts to 
slowly flash.

When used in conjunction with other compatible Grace Lone 
Worker  products,  a  complete  system  test  may  be  initiated 
by pressing and holding the Select button for three seconds. 
After Select has been held for three seconds a Link Query 
message is transmitted, and the SuperCell

TM

 display shows 

a  round  trip  timer,  used  to  measure  the  complete  system 
path test time:

System Test Screen

The display will show the following when a Link Status mes-
sage  is  received,  in  conjunction  with  a  power-up  sound  
sequence:

System Test Successful Screen

If no Link Status Acknowledgment message is received after 
five minutes, this will be indicated via a simple audio beep 
and a message similar to the one below:

System Test Timed Out Screen

Note: The complete system path may contain items beyond 
the control of Grace Industries, such as satellite delays. Sys-
tem Test times could vary considerably.

Mobile Lone Worker Applications

SC500-OR with Out of Range Notification 

The  SC500-OR  is  similar  to  the  standard  SC500  in  most 
respects  but  with  the  added  feature  of  notifying  the  user 
when they have exceeded the effective signaling range of a 
compatible MX900 transceiver. The MX900 transceiver, with 

Charging  
Base

which the SC500-OR is to be used, must have its Ping fea-
ture turned ON. The two devices operate as a system where-
by the MX900 unit (with its PING feature turned on) will echo 
back a normal on-mode polling signal that is received from a 
Grace Industries SC500-OR two-way signaling device. The 
SC500-OR device will receive the echo of its own on-mode 
polling signal (sent from the MX900) and resets the Out-of-
Range Notification timer. If the echoed signal sent from the 
MX900 is not received, or conversely the MX900 does not 
receive a polling signal from the SC500-OR within approxi-
mately 3 minutes, an audible warning sound will activate on 
the SC500-OR indicating the effective range of the system 
has been exceeded. This audible Out-of-Range notification 
(a bell-like, double-chirping sound) will occur approximately 
every 30-40 seconds until the signal link between the SC500-
OR and MX900 is re-established.

System Link Test 

12VAC Charger 
Adapter

System Test Sent Screen

 

      AM16
System Test
Hold Select 3Sec

             

 

      
System Test Sent
Successful 

 

      
System Test 
Timed Out 

 

      
System Test Sent
Trip Time: 0027 

Summary of Contents for SuperCell SC500

Page 1: ...represent the SC500 unit I D The bottom left line of the screen shows the radio frequency the radio firm ware revision and the type of firmware The SuperCellTM is turned OFF by simultaneously pressing both PWR buttons and holding for about three seconds or until the display shows the message Off This is accompa s e n o t o i d u a g n i p e e w s n w o d n e h t d n a p u s e i r e s a y b d e i n...

Page 2: ... Up Dwn buttons to chose the desired message Up and Down change the message count by one while and change the count by 16 Once a message is selected press and hold the Select button for approximately three seconds the message will be transmitted and a Message Sent acknowledgment will be displayed on the screen Use Up Dwn buttons to choose other messages or the Menu button to leave the Send Mes sag...

Page 3: ... audio beep and a message For more information on System Link Test see Mobile Lone Worker Applications later in User s Guide System Link Test Screen SC500 settings that are rarely changed are under the Setup Menu Press SELECT to enter the Setup Mode and press the Menu button to cycle through the ten SC500 setup screens To exit the Setup Mode reset the unit by simulta neously pressing and releasing...

Page 4: ...ent users from un knowingly wondering out of range of the base mobile sys tem The Signal Lost Timer option may only be used in con junction with other compatible Grace Lone Worker products turning it ON without these products in range results in a Signal Lost alert message frequently ap pearing Simply disable this alert to prevent these mes sages The SC500 is shipped with the Signal Lost Timer opt...

Page 5: ...led as described in the previous section the Alarm button will not make any local sound even if this setting is enabled As supplied from the factory pressing the Alarm button does NOT generate an Alarm sound Backlight Setup Mode Screen 10 Pressing the Select button will toggle the Backlight state be tween Enabled Disabled It may be desirable to disable the back light in covert operations or situat...

Page 6: ...t time System Test Screen The display will show the following when a Link Status mes sage is received in conjunction with a power up sound sequence System Test Successful Screen If no Link Status Acknowledgment message is received after five minutes this will be indicated via a simple audio beep and a message similar to the one below System Test Timed Out Screen Note The complete system path may c...

Page 7: ...ED and optional Audible Alert Optional audible tones for alarm alarm received call back and reset Check in Status Signal Periodically transmitted to LCD T3 SM2000 Command Bases Watchdog and many other Grace Telemetry products SuperCellTM SC500 SPECIFICATIONS AND FEATURES When a train is detected the Train Detector sends an Evacu ation Alarm signal to the SC500 The SC500 displays the EVACUATION mes...

Page 8: ...305 Bend Hill Road Fredonia PA16124 U S A 724 962 9231 www graceidustries com Grace Industries Inc Printed in U S A SuperCell 500 06 2011 UI ...

Reviews: