background image

Mod. IO 09/I Rev. 01 

 

OVERALL DIMENSIONS AND POSITIONING 

- The barrier movement mechanism is easily adaptable to provide 
right-hand or left-hand closing (as seen from the barrier side). See 
instructions for changing the opening side.  
- For safe use, it is necessary to provide suitable space for the 
automatism access panel opening (P) and to be able to activate the 
unblocking key (CH) for the emergency manoeuvre. 
- Secure to the flooring takes place using an anchoring counter 
plate equipped with suitable anchor bolts to embed in the jet of 
concrete. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

The following table summarises the main overall barrier 
dimensions:  
 

Model  

Max 

length 

Hsb H 

c Wid. 

Depth  

GR4000 
GR6000 

6000 900 1225 325  225 

 
SAFE OPERATING CONDITIONS: 

To operate the barrier: 
 
- Affix the adhesive band with reflective strips onto the barrier arm, 
to highlight it;  
 
- Install a fixed support at the end of the barrier;  
 
- Install a system of photocells, as shown in the figure, to prevent 
the automatic re-closing system from intervening during the transit 
of persons or vehicles; 
 
- Check that, in the open and closed positions, the barrier is easily 
visible both during the day and at night. Add suitable additional 
lighting where necessary;  
 
- Install a flashing light to activate during barrier movement 
(optional) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

ADJUSTING THE LIFTING FORCE GENERATED BY THE 
SPRING  

- After switching off the power supply, access the barrier 
automatism through the opening in the panel (P).  
- With the use of a CH32 fixed spanner, loosen the lower nut and, 
by turning the stainless steel stem by hand, the following occurs:  
in a clockwise direction, the length of the threaded bar increases 
(the preload increases and counterbalances a longer or heavier 
arm).  
 in an anti-clockwise direction, the length of the threaded bar 
decreases (the preload decreases and counterbalances a shorter 
or lighter arm).  
- Once adjustment is complete, tighten the counter-nut using the 
fixed spanner.  
 
 
  

 
 
 
 
 
 
 
 
 

!

It is strictly forbidden to adjust the spring so 
that the force to overcome to stop it is greater 
than 15 kg (150N) 

 
MODIFYING THE BARRIER CLOSING DIRECTION 
(RIGHT/LEFT)  

NOTE, THE CORRECT DIRECTION OF THE BARRIER IS WHEN 
THE MOTOR PISTON IS EXTENDED, THE BAR IS RAISED! 

The barrier is supplied with the closing as requested (right/left) (as 
seen from the barrier side).  
If the direction of access is to be inverted, the barrier is fully 
reversible and with simple operations, it is possible to readapt it, 
following the instructions below.  
 
- Disconnect power to the barrier, lock the switch with the key and 
open the hatch (P) and the head cover (C). 
 
- Lighten the load on the spring as explained in the chapter 
“Adjusting the lifting force generated by the spring”, turn the 
stainless steel stem until the threaded bar disappears. 
 
- Remove the fasteners from the ends of the electrical piston 
(threaded lock pin and pin).  
 
-

 

Reposition the arm of the automatism on the other side, first 

securing it at the base and then at the top, inserting the pin in the 
eyelet, and reloading the spring preload.  
 
- Adjust the spring as already described. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

!

 

The spring still remains slightly preloaded. In 
the extraction phase, pay attention to the 
danger of crushing due to the unexpected 
extension of the spring as highlighted by the 
affixed adhesive. 

H sb

H c

P c

L c

P

CH

Reviews: