Mod. IO 09/I Rev. 01 

DEMOLITION 

The materials must be disposed of in 
compliance with standards in force. If materials 
are to be recycled, it is advisable to separate 
them according to type (copper, aluminium, 
plastic, electrical components etc.).  

 
For EU countries only 

Do not dispose of the GR 3000 moveable barrier and system 
components as household waste! This is an explicit warning that GR 
opening systems and system components must not be disposed of as 
household waste nor taken to local collection centres! 
 
In accordance with European directive 2002/96/EC regarding the 
recycling of electrical equipment and its implementation in national 
law, GR offers a fee-paying service for the collection and 
environmentally-friendly disposal of its equipment and system 
components.  
 

DISMANTLING 

To dismantle the automation in another location, proceed as follows: 
1 - disconnect the power supply and the electrical system;  
2 - remove the control panel and all the installation components. 
If any components are damaged or are impossible to remove, replace 
them. 

 

DECLARATION OF CONFORMITY 

The GR 4000 230 V moveable barrier 
Complies with the conditions of the Machinery Directive 2006/42/EC – 
Directive of the European Parliament and Council of 17 May 2006, on 
the approximation of the laws of the Member States relating to 
machinery  
 

 

Complies with the conditions of the following other EC directives: 
Electromagnetic Compatibility Directive 2004 /108/EC; 
 

 

And also declares that the following harmonised standards have been 
applied 
- EN 292 1 / 2 - Safety of machinery - General principles for design 
- EN 294         - Safety of machinery - Distances to prevent danger 
zones being reached. 
- EN 60335-1 - Safety of household and similar electrical appliances - 
general requirements. 
- UNI EN 12 453  - Safety in use of power operated doors - 
requirements 
 
where applicable, the technical provisions of product standards have 
also been observed 
- EN 12445-2000  Safety in use of power operated doors – Test 
methods - 
 
This declaration of conformity is therefore issued in accordance with 
Directive 2006/42/CE as per Annex II paragraph A.

 

 

USING THE AUTOMATION - GENERAL DESCRIPTION  

The GR 4000 and GR 6000 barriers are suitable for managing 
passageways with average levels of transit and comply with the  
UNI 12 453 standard. 
- The movement of the bar is regular with gradual decelerations 
at the opening and closing positions. The barrier is identified by 
the CE marking plate.  
-  A patented intrinsic safety system prevents the barrier from 
falling in the event of the breakage of any component of the 
control chain, moving the barrier back to the passage open 
position. 
- adjusting the run between the two mechanical end runs and 
balancing the barrier by preloading the movement return spring is 
easy by moving the nut/counter-nut sets. 
- In the event of a power cut, a simple key unblocking system 
allows the automatism to be unblocked with the consequent 
intervention of the return spring which moves the barrier to the 
vertical position without any external help. 
- The crush-prevention safety device is ensured by the 
preloading of the spring which opposes the action of the 
automatism which, where suitably calibrated, ensures that a force 
is available for movement which guarantees that the barrier stops 
upon minimal contact with an obstacle. 
- The load-bearing casing is made of galvanised steel and is 
powder-painted. 
- Movement is ensured by an asynchronous motor in order to 
guarantee high levels of reliability over time.  
- Possibility to control the motor directly from an automatic 
external control system. 
- Adjustable mechanical end runs with bar open and bar closed 
contacts available as signals for the automation system.   
- Adjustable slowdown limit switch managed by the electronic 
control unit.  

 
EQUIPMENT 

In order to install the automation, the following equipment is 
necessary: spanners, screwdriver, ruler, spirit level, saw, drill, 
welder. 

 

PRELIMINARY CHECKS 

1 - Read the instructions in the manual very carefully.  
2 - Check that the electrical system complies with the 
characteristics required by the gear motor.  
 

 

 

 

TECHNICAL DATA

 

GR4000 230V

 

GR6000 230V

 

  

  

  

POWER SUPPLY

 (V 220AC 50/60Hz) 

230 

230 

INPUT POWER (W)

 180 

350 

INPUT CURRENT(A)

 0.8 

1.0 

CAPACITATOR (µF) 

 8.0 

12.5 

OPENING TIME (sec)

 4.5 

8.5 

CLOSING TIME (sec)

 4.5 

8.5 

MAX. BAR LENGTH (m)

 4.0 

6.0 

MOTOR SPEED

 2800 

1400 

OPERATING TEMPERATURE

 (°C) 

-25 +60 

-25 +60 

THERMAL PROTECTION 

(°C) 150 

150 

PROTECTION RATING (IP)

 40 

40 

WORKING CYCLE (%) / DAILY MANOEUVRES 

 

80 / > 4000 

80 / > 4000 

MOVEMENT

 ELECTROMECHANICAL 

PISTON 

ELECTROMECHANICAL 

PISTON 

UNBLOCKING

 

MANUAL - WITH KEY 

MANUAL - WITH KEY 

DIMENSIONS AND WEIGHT

 

324x282x1130mm / 44.0 kg 

324x282x1130mm / 44.5 kg 

 

 
 
 

 
 