background image

6

All other horizontal deep well jet pumps, ¾

  

hp and 

larger, should use an AV22KIT, or an AV22 and a JDW 

tubing kit. The AV22 has a tapping to which you connect 

the new, longer pressure switch tubing. This allows the 

pressure switch to read the pressure on the outboard 

side of the valve rather than in the pump casing. Remove 

the straight or elbow compression fitting from the pump 

casing. Use the pipe plug in the JDW or AV22KIT to plug 

the hole in the pump casing. Remove the fitting from 

the pressure switch. Cut the old tubing in half and slide 

the compression fittings off the old tubing. Note that the 

fitting will only slide in one direction. You can now reuse 

the elbow compression fitting with the new tubing at the 

pressure switch. Screw the new straight connector into 

the AV22 and attach the tubing from the switch to the 

AV22.

Vertical deep well pumps come with a built-in AV21 and 

only need to be adjusted.

After the pump is primed and flowing water at a steady 

pressure you should open a few faucets and adjust the 

pressure control valve to the pressure listed in the chart. 

To increase pressure close the valve, AV15 or AV22, or 

turn the AV21 screw clockwise. See Chart 1.

ALL SYSTEMS

Install HydroPro Water Systems Tank

While the tank is empty check the pre-charge 

air pressure with a tire pressure gauge. The 

tank pre-charge should be set 2 psi lower than 

the pump cut-in (turn on) pressure. On Goulds 

Water Technology HydroPro Water Systems 

tanks the valve cap is the primary seal so be 

sure to re-install the cap after checking air 

pressure. Avoid frequent air checking as you lose 1 – 2 

psi every time you check. Goulds Water Technology jet 

pumps are all supplied with 30 – 50 psi standard pressure 

switch settings.

Locate the tank on a firm, level surface.

A pressure relief valve is recommended for all systems, 

and mandatory for systems producing over 100 psi. It 

should be rated less than 100 psi but greater than the 

system pressure near the tank.

Make the piping connection between the pump discharge 

and the tank. Complete the piping by connecting to the 

house plumbing.

Note: Goulds Water Technology only sells the HydroPro 

Water System tanks. They are all shipped with a tank 

installation guide in the carton, please refer to it for more 

detailed tank instructions. If you are using a tank from 

another manufacturer please contact that company for 

specific instructions on their tank.

Galvanized tanks are installed the same as pre-charged 

tanks except they require an Air Volume Control (AVC) 

to replenish air lost through absorption. The AVC re-

quires connection to a vacuum port on the pump. The 

suction side of the AVC must have a minimum 3" vacuum 

for 15 seconds when the pump starts. Follow the instruc-

tions provided with the air volume control.

Priming a Shallow Well System

Priming means filling the pump and suction pipe with 

water. Most shallow well jet pumps handle air well and 

will evacuate air from the suction line but it may take 

several minutes to prime depending on depth to water, 

and pipe size and length. 

VENT THE PUMP FOR EASIER PRIMING!
It is easier to prime a pump if you allow all the air to 

escape from the pump and the pipes, the water cannot go 

in unless the air can escape! 

Remove the pipe plug or pressure gauge bushing in the 

discharge tee to fill the pump with water. On shallow 

well pumps you should remove the 

1

8

" pipe plug located 

between the suction and discharge ports to allow air to 

escape as you fill the casing with water. The port will be 

located on either the top of the casing or the top of the 

shallow well adapter. Fill the pump and as much of the 

suction pipe as possible with water through the discharge 

port.

Replace the 

1

8

" pipe plug and discharge gauge/bushing. 

Open the faucet closest to the pump/tank a small amount 

to allow air to escape the system. Do not open it too 

much or the pump will expel too much water and you 

will have to reprime the pump casing. On jobs with long 

suction pipes you may have to add water to the pump 

casing several times to complete the priming process.

Go to Power Motor.

Priming a Deep Well System

Priming a deep well system means filling the pump and 

the suction/pressure pipes with water. Deep well single 

stage and multi-stage pumps require a complete prime 

before starting. Filling the pipes with water before instal-

ling the pump will make priming faster and easier. 

VENT THE PUMP FOR EASIER PRIMING!
To insure a complete prime we recommend removing the 

angled 

1

8

" vent plug located just above the suction pipe 

on horizontal pumps. This will allow the air to easily 

escape as water enters. Our horizontal convertible deep 

well jets should be primed through a tee or the AV22 at 

the pump discharge. The tee is not supplied by Goulds 

Water Technology.

Our vertical deep well jet pumps have built-in pressure 

control valves. Priming is done through the pressure 

gauge port on the pressure control valve. Most verticals 

have a vent plug located on the side of the motor adapter 

that vents the seal cavity which is the high point inside 

the pump. Removing this vent plug will make priming 

much easier.

AV22

ALL SYSTEMS

Fig. 4

AV15

AV21

Hazardous pressure can
cause personal injury or
property damage.

WARNING

Summary of Contents for HSJ07

Page 1: ...Jet Pumps INSTALLATION OPERATION AND TROUBLESHOOTING MANUAL INSTRUCTION MANUAL IM102R07 ...

Page 2: ...alling or servicing any electri cal equipment Many pumps are equipped with auto matic thermal overload protection which may allow an overheated pump to restart unexpectedly Never over pressurize the tank piping or system to a pressure higher than the tank s maximum pressure rating This will damage the tank voids the warranty and may create a serious hazard Protect tanks from excessive moisture and...

Page 3: ...re are two types of deep well jet assemblies twin pipe and packer systems Deep well pumps come in both vertical and horizontal designs and in single and multi stage models See Typical Installation Drawing Fig 2 and 3 Consult with your Professional Dealer or Distributor to select the best pump system for your application Liquid temperature must not exceed 140 F 60 C Protect unit from freezing SHALL...

Page 4: ...o prevent over pumping a low yield well you can throttle a jet pump using a ball valve in the suction line You should install a compound pressure vacuum gauge between the well and the valve Do not throttle to more than 22 Hg 25 lift In areas where freezing occurs make the transition from vertical to horizontal below the frost line using a pitless adapter consult with your plumbing supplier for pit...

Page 5: ...ommended pipe may reduce gpm output The longer the pipe the worse the affect Install Packer Assembly To ease installation soak the 2 or 3 packer assembly in warm water to make the leathers soft and pliable DO NOT lubricate them with grease oil or petroleum jelly The leathers must absorb water to seal the packer assem bly against the well casing Check to make sure the nozzle is installed in the jet...

Page 6: ...ol AVC to replenish air lost through absorption The AVC re quires connection to a vacuum port on the pump The suction side of the AVC must have a minimum 3 vacuum for 15 seconds when the pump starts Follow the instruc tions provided with the air volume control Priming a Shallow Well System Priming means filling the pump and suction pipe with water Most shallow well jet pumps handle air well and wi...

Page 7: ...ly Black and neutral N usually white 115 volt wires to on the switch The same goes for a 230 volt hook up either wire can go on either Line terminal Re install the switch cover NOTE Motor voltage is NOT changed in the pressure switch See Fig 7 in Technical Data Check to insure that the motor is wired to match the incoming voltage All motors have a sticker near the pressure switch that identifies t...

Page 8: ...3 53 3 27 30 70 AWCJ3 AV22 and JDW FT5 48 4 40 70 110 FP3 54 3 30 70 110 FT4 44 4 31 30 60 FP2 48 2 35 30 60 AWJ2 FT4 43 4 33 60 80 FP2 43 2 36 60 100 AV22KIT J10 FT4 18 4 35 80 110 AV22 and JDW FT5 49 4 30 30 80 FP3 55 3 28 30 80 AWCJ3 FT5 11 4 32 80 120 FP3 14 3 32 80 120 FT5 12 4 35 30 70 FP3 16 3 34 30 60 J15 FT5 11 4 40 70 140 FP3 18 3 34 60 90 AWCJ3 AV22KIT FP3 21 3 34 90 150 AV22 and JDW FP...

Page 9: ...ONTROLVALVE DEPTH JET WELL CONTROLVALVE DEPTH PACKER CONTROLVALVE ASSEMBLY DIAMETER SETTING PSI TO JET ASSEMBLY DIAMETER SETTING PSI TO JET ADAPTER see fig 4 FT3 09 3 30 30 50 FP2 13 2 30 30 50 FT4 13 4 30 30 50 AV15 JRD5 FT4 31 4 30 30 70 FP2 31 2 30 30 60 AWJ2 or FT4 08 4 30 60 90 FP2 08 2 30 60 80 AV22KIT FT5 14 4 30 70 90 FT4 14 4 27 30 60 FP2 40 2 30 30 60 FT4 34 4 29 60 90 FP2 47 2 32 60 90 ...

Page 10: ...JB05 C48C04A06 115 230 1 1 6 12 6 6 3 990 25 15 SFJ05860 JRS7 JRD7 JB07 C48C05A06 115 230 1 1 5 14 8 7 4 1200 30 15 SFJ06860 JRS10 JRD10 JB10 C48C06A06 1 115 230 1 1 4 16 2 8 1 1400 30 20 Effective July 1998 230 V only VOLTAGE CHANGE PROCEDURE AND TERMINAL BOARD DESIGN Jet pump motors have a voltage plug to facilitate simple voltage changes from 115V to 230V All HP motors are fac tory wired for 11...

Page 11: ...less than pump capacity throttle a ball valve in suction line do not exceed 22 Hg to reduce pump capacity USE OF TAILPIPE ON DEEP WELL JET PUMPS If the capacity of a deep well jet pump exceeds the well production well drawdown will allow your pump to break suction and lose prime This can be overcome by using a 34 tailpipe between the jet assembly and the foot valve Since the capacity of a pump fal...

Page 12: ... have these definitions 1 Distributor means any individual partnership corporation association or other legal relationship that stands between Goulds Water Technology and the dealer in pur chases consignments or contracts for sale of the subject pumps 2 Dealer means any individual partnership corporation association or other legal relationship which engages in the business of selling or leasing pu...

Page 13: ...MANUAL DE INSTRUCCIÓN IM102R07 Bombas de Inyección MANUAL DE INSTALACIÓN OPERACIÓN E IDENTIFICACIÓN Y RESOLUCIÓN DE PROBLEMAS ...

Page 14: ...rvicio a cualquier equipo eléctrico Muchas bombas están equi padas con protección automática contra la sobrecarga térmica la cual podría permitir que una bomba demasiado caliente rear ranque inesperadamente Nunca presurice demasiado el tanque las tuberías o el sistema a una presión superior a la clasificación de presión máxima del tanque El hacerlo dañará el tanque anula la garantía y puede crear ...

Page 15: ...vaciones de más de 25 pies y deben tener dos tuberías que vayan al pozo Hay dos tipos de conjun tos de inyección para pozos profundos los sistemas de tubo doble y los sistemas de obturador Las bombas para pozos profundos se ofrecen en diseños tanto verticales como horizontales y en modelos de una etapa y de etapas múltiples Consulte los dibujos de instalaciones típicas Figuras 2 y 3 Consulte con s...

Page 16: ...ar Para impedir bombear en exceso un pozo de baja producción usted puede estrangular una bomba de inyección con una vál vula de bola en la línea de succión Usted debe instalar un indicador compuesto de presión vacío entre el pozo y la válvula No estrangule a más de 22 pulg Hg 25 pies de elevación En áreas donde ocurre congelación haga la transición de vertical a horizontal debajo del nivel de pene...

Page 17: ... de la bomba y tanto la presión como los gpm disminuirán La bomba puede perder cebado fácilmente durante el bombeo debido a la restricción Si se utiliza tubería más pequeña que la recomendada podría reducirse la salida de gpm Mientras más larga es la tubería peor es el efecto Instale el conjunto del obturador Para facilitar la instalación remoje el conjunto del obtu rador de 2 ó 3 pulgadas en agua...

Page 18: ...de su tanque Los tanques galvanizados se instalan de la misma manera que los tanques precargados excepto que requieren un control de volumen de aire AVC para reponer el aire perdido por absorción El control de volumen de aire requiere una conexión a un orificio de vacío en la bomba El lado de succión de dicho control debe tener un mínimo de 3 pulg de vacío durante 15 segundos cuando arranca la bom...

Page 19: ... a las terminales de línea del interruptor por caída de presión Conecte el alambre verde o alambre desnudo de con exión a tierra a cualquiera de los tornillos verdes de conexión a tierra en el interruptor No hace ninguna dife rencia a qué terminal de línea se conecte el alambre L1 activado habitualmente de color negro y el neutro N de 115 voltios en el interruptor Lo mismo corresponde a la conexió...

Page 20: ... 14 4 28 30 60 FP2 40 2 30 30 60 AWJ2 FT4 34 4 29 70 90 FP2 47 2 32 60 90 AV22KIT J7 FT4 18 4 30 90 110 o FT5 47 4 28 30 70 FP3 53 3 27 30 70 AWCJ3 AV22 and JDW FT5 48 4 40 70 110 FP3 54 3 30 70 110 FT4 44 4 31 30 60 FP2 48 2 35 30 60 AWJ2 FT4 43 4 33 60 80 FP2 43 2 36 60 100 AV22KIT J10 FT4 18 4 35 80 110 AV22 y JDW FT5 49 4 30 30 80 FP3 55 3 28 30 80 AWCJ3 FT5 11 4 32 80 120 FP3 14 3 32 80 120 F...

Page 21: ...INYECCIÓN POZO LBS PULG CUADR INYECTOR INYECCIÓN LBS PULG CUADR INYECTOR OBTURADOR FT3 09 3 30 30 50 FP2 13 2 30 30 50 FT4 13 4 30 30 50 AV15 JRD5 FT4 31 4 30 30 70 FP2 31 2 30 30 60 AWJ2 o FT4 08 4 30 60 90 FP2 08 2 30 60 80 AV22KIT FT5 14 4 30 70 90 FT4 14 4 27 30 60 FP2 40 2 30 30 60 FT4 34 4 29 60 90 FP2 47 2 32 60 90 AWJ2 AV22KIT JRD7 FT4 18 4 30 90 110 AV22 y JDW FT5 47 4 27 30 70 NA FT5 48 ...

Page 22: ...7 JRD7 JB07 C48C05A06 115 230 1 1 5 14 8 7 4 1200 30 15 SFJ06860 JRS10 JRD10 JB10 C48C06A06 1 115 230 1 1 4 16 2 8 1 1400 30 20 Fecha de vigencia julio de 1998 230 V únicamente DATOS TÉCNICOS Fig 7 PROCEDIMIENTO PARA EL CAMBIO DE TENSIÓN Y DISEÑO DE LA PLACA TERMINAL Los motores de las bombas de chorro A O Smith tienen un tapón de tensión para facilitar cambios simples de tensión de 115V a 230V To...

Page 23: ...cidad de la bomba estrangule una válvula de bola en la línea de succión sin exceder 22 pulg de Hg para reducir la capacidad de la bomba USO DEL TUBO DE ASPIRACIÓN EN BOMBAS DE INYECCIÓN PARA POZOS PROFUNDOS Si la capacidad de una bomba de inyección para pozos profundos excede la producción del pozo el descenso de nivel del pozo hará que la bomba interrumpa la succión y pierda cebado Esto puede cor...

Page 24: ...rporación asociación u otra persona jurídica que opera en relación legal entre Goulds Water Technology y el comerciante para la compra consignación o contratos de venta de las bombas en cuestión 2 Comerciante es todo individuo sociedad corporación asociación u otra persona jurídica que en el marco de una relación legal realiza negocios de venta o alquiler venta leasing de bombas a clientes 3 Clien...

Page 25: ...Pompes À Jet MANUEL D INSTALLATION D UTILISATION ET DE DÉPANNAGE MANUEL D UTILISATION IM102R07 ...

Page 26: ... ou l entretien des dispositifs électriques Le protecteur thermique de certains moteurs coupe le courant lorsqu il y a surcharge thermique et le rétablit automatiquement redémarrant ainsi la pompe inopinément Pour le système et le réservoir ne jamais utiliser une pression excédant la pres sion nominale maximale de ce dernier afin de ne pas l endommager annuler la garantie ni constituer un grave da...

Page 27: ... descendant dans le puits Il en existe deux types à tuyaux jumelés ou à tuyaux concentriques Les pompes pour puits profonds sont offertes en versions horizontales ou verticales multi étagées ou non Voir les systèmes types aux fig 2 et 3 Consulter un détaillant professionnel ou le distributeur pour choisir le système qui convienne le mieux La température du liquide ne doit pas dépasser 60 C 140 F P...

Page 28: ...ou dans la pompe Dans le cas des installations à pointe filtrante ou en puits tubulaires on peut poser un clapet de non retour près de la tête de puits ou de la pompe et utiliser le cuvelage comme tuyau d aspiration Plus le clapet de non retour est près du puits plus l amorçage sera facile Pour empêcher le surpompage des puits à faible débit on peut poser un robinet à tournant sphérique sur le tuy...

Page 29: ... de soupapes ni de filtres entre la pompe et le réservoir sauf s il s agit d un robinet vanne grand ouvert ou d un robinet à tournant sphérique à passage intégral La plupart des robinets à tournant sphérique ordinaires ne sont pas à passage intégral La majorité des soupapes des robinets et des filtres causent une perte de charge excessive et le cliquetis répétitif du pressostat fonctionnement cycl...

Page 30: ...our puits profonds Amorcer un système pour puits profonds signifie remplir d eau les tuyaux d aspiration et d alimentation en eau motrice ainsi que la pompe Les pompes multi étagées ou non pour puits profonds requièrent un amorçage complet avant d être mises en service Remplir les tuyaux avant d y fixer la pompe facilite l amorçage et fait gagner du temps Fixer la pompe à l adaptateur de tête de p...

Page 31: ...étique DISJONCTEUR OU BOÎTE À FUSIBLE S PRESSOSTAT ROB À TOURNANT SPHÉR DANGER Lestensionsdangereuses peuventcauserunchoc électrique desbrûlureset lamort DANGER Lestensionsdangereuses peuventcauserunchoc électrique desbrûlureset lamort NE JAMAIS FAIRE FONCTIONNER LA POMPE À SEC CAR CELA L ENDOMMA GERAIT ET ANNULERAIT LA GARANTIE ON DOIT TOUJOURS VERROUILLER LE DISJONCTEUR OU LE SECTIONNEUR SELON L...

Page 32: ... 120 FT5 12 4 35 30 70 FP3 16 3 34 30 60 J15 FT5 11 4 40 70 140 FP3 18 3 34 60 90 AWCJ3 AV22KIT FP3 21 3 34 90 150 AV22 et JDW FP3 24 3 39 100 170 FT4 48 4 37 30 70 FP2 51 30 70 SJ07 et FT4 47 4 40 70 90 FP2 50 2 40 70 90 AWD2 HSJ07 FT4 06 4 90 130 FP2 06 90 130 FP3 40 3 36 30 80 AWD3 FP3 42 40 80 130 FT4 47 4 40 30 70 FP2 50 30 60 SJ10 et FT4 24 4 43 70 110 FP2 07 2 45 60 110 AWD2 HSJ10 FT4 08 4 ...

Page 33: ...WJ2 AV22KIT JRD7 FT4 18 4 30 90 110 AV22 et JDW FT5 47 4 27 30 70 S O FT5 48 4 30 70 110 FT4 44 4 31 30 60 FP2 48 2 35 30 60 FT4 43 4 33 60 80 FP2 43 2 36 60 100 AWJ2 AV22KIT JRD10 FT4 18 4 35 80 110 AV22 et JDW FT5 49 4 28 30 80 S O FT5 11 4 32 80 120 FT4 46 4 23 30 60 FP2 38 2 30 60 AWD2 VJ05 FT4 08 4 60 90 FP2 08 23 60 90 30 60 FP3 42 3 30 60 AWD3 60 100 FP3 09 60 100 FT4 47 4 34 30 60 FP2 50 3...

Page 34: ...05 C48C04A06 115 230 1 1 6 12 6 6 3 990 25 15 SFJ05860 JRS7 JRD7 JB07 C48C05A06 115 230 1 1 5 14 8 7 4 1200 30 15 SFJ06860 JRS10 JRD10 JB10 C48C06A06 1 115 230 1 1 4 16 2 8 1 1400 30 20 230 V seulement à partir de juillet 1998 DONNÉES TECHNIQUES Fig 7 DANGER Lestensionsdangereuses peuventcauserunchoc électrique desbrûlureset lamort COMMUTATION DE TENSION AU BORNIER Le bornier des moteurs A O Smith...

Page 35: ... débit de celle ci à l aide d un robinet à tournant sphérique posé sur le tuyau d aspiration et réglé pour augmenter la dépression qui ne doit cependant pas dépasser 22 po de Hg EMPLOI D UN TUYAU RALLONGE AVEC LES POMPES À JET POUR PUITS PROFONDS Si le débit d une pompe à jet pour puits profonds dépasse le débit entrant du puits il en résultera un rabattement baisse de niveau excessif donc l aspir...

Page 36: ... servant d intermédiaire entre Goulds Water Technology et le détaillant pour les achats les consignations ou les contrats de vente des pompes en question 2 Détaillant veut dire une personne une société de personnes une société de capitaux une association ou autre entité juridique dont les activités commerciales sont la vente ou la location de pompes à des clients 3 Client désigne une entité qui ac...

Reviews: