Device Description HG G-19603ZA | English, Revision 03 | Date: 31.03.2021
28
Chapter 6 – Software
Afterwards the file can be imported into a spreadsheet application (e.g. Microsoft®
Excel®) and analyzed.
Figure 19
CSV recording imported into a spreadsheet application
6.4.3 (2) Settings
By using the key
in the main menu the
settings
menu of the magnet sensor is
opened.
Figure 20
Menu settings (showing CAN STD, CANopen@ has specific settings)
Changed parameters are notn automatically saved. if they are to be used perma
-
nently use
save settings to save them.
changes the polarity of the magnetic tape (
south
= magnetic south pole on
the top;
north
= magnetic north pole on the top, default; s. section 3.1 on
threshold for the detection of a single magnetic tape
threshold for the detection of two magnetic tapes
choose CAN configuration (CAN STD / CANopen®)
set CAN baud rate (125 kbit/s, 250 kbit/s, 500 kbit/s, 1 Mbit/s)
–
CAN STD: specific settings
or
–
CANopen®: specific settings
calibration settings, see section 6.4.4 on page 29
reset parameters to factory settings
save settings permanently
firmware update (see section 6.4.6 on page 30)
HG 19603 Serialnumber: 123456 Firmwareversion: V1.01
settings
Range:
(1) track polarity : north
(2) sensitivity : 0.200 [mT] 0.01 .. 2
(3) sen. two tracks: 0.800 0.1 .. 4
(4) CAN Mode : CAN
(5) CAN Baudrate : 1000 KBit/s
(6) CAN ID Tx : 0x03F / 0063d 0x000 .. 0x7FF
(7) CAN ID Rx : 0x040 / 0064d 0x000 .. 0x7FF
(8) datarate : 10 [ms] 1 .. 100
(C) calibration
(D) load default settings
(S) save settings
(F) firmware update
(ESC) QUIT