either activates the permanent output, according to the
Clock for Sampling
set
in Time&Code (
1
; refer to 5.2.2.2 on page 33), or generates the output solely when a
transponder is decoded within the reading range of the antenna (
0
).
activates remote operation. In this mode (independent of the settings of
Conti-
nuous Telegrams
), telegrams are no longer generated, but only to remote frames
answered with the corresponding address.
With
the repetition rate of the data output can be selected.
The content of the CAN value status is shown in the upper line of the menu. These val-
ues are used for simple diagnosis. They are explained in above mentioned Processor
Manual on page 23-7.
5.2.2.5
P(r)ofibus-Parameters
This menu enables setting the Profibus parameters.
ATTENTION!
In case the Profibus is not connected and if the antenna in ques-
tion is a version HG 98780ZA/WA (in contrast to versions YA/XA),
the Profibus must (!) be deactivated. If the Profibus is not deacti-
vated, transmission errors will lead to an antenna reset!
Figure 18
Menu: P(r)ofibus-Parameters
On the left hand side of the screen, the bytes transmitted to the master as well as the
bytes transmitted by the master are displayed. The description of these bytes is in-
cluded in Table 15 on page 25.
Byte # Master-Input Profibus-Status: NO_ERROR
0 02
1 00
2 00
3 00
4 00
5 00
6 f0
7 0f
8 1c (P)rofibus active YES
9 00 (A)ddress: [0..125]: 2
10 00 (O)rder of Data Transfer (0= HiByte first): 0
11 02
12 0b (Q)uit Menue
Byte # Master-Output
0 00
1 00
2 00
3 00
4 00