5.2.2.2
(T)ime & Code
This menu enables the setting of timing values for the transponder decoding, the po-
sition calculation and the positioning pulse.
Figure 14
Menu: (T)ime & Code
With
the voltage threshold S for the release of the output of the positioning pulse is
set in order to eliminate wrong outputs.
With
the voltage threshold S for the start of the code decoding is set in order to pre-
vent decoding tries during a weak signal period.
With
it is possible to switch on the reference transponder for testing.
The duration of the positioning pulses can be set in a millisecond pattern by pressing
.
S:0544 X:+0000 Code: 00000000 Read: 0
U[/mV]:24000 I[/mA]: 150 T[Grd.C]:+28 E: 0200 N: 0
Ftx[/Hz]:105970 Prog_Code: 00000000
(L)evel for Positioning [10.1023]: 256
(T)hreshold Decoding [10.1023]: 256
(1) switch Reference Transponder: 0
(P)osi-Pulse Time [n*1ms]: 100
(Q)uit Menue