39
English
Table 1:
Sym- Meaning
Application
bols
(see table 4)
A11
A34
A24 /
…
A44
A16
U
Input voltage
●
––
––
U12
Phase-to-phase voltage
––
●
●
L1 – L2
U23
Phase-to-phase voltage
––
●
●
L2 – L3
U31
Phase-to-phase voltage
––
●
●
L3 – L1
U1N
Phase-to-neutral voltage
––
––
●
L1 – N
U2N
Phase-to-neutral voltage
––
––
●
L2 – N
U3N
Phase-to-neutral voltage
––
––
●
L3 – N
UM
Average value of the
––
––
●
voltages
I
Input current
●
––
––
I1
AC current L1
––
●
●
I2
AC current L2
––
●
●
I3
AC current L3
––
●
●
IM
Average value of the
––
●
●
currents
IMS
Average value of the currents
––
●
●
and sign of the active power
IB
RMS value of the current
●
––
––
with wire setting range
(bimetal measuring function)
IB1
RMS value of the current
––
●
●
with wire setting range
(bimetal measuring function),
phase 1
IB2
RMS value of the current
––
●
●
with wire setting range
(bimetal measuring function),
phase 2
IB3
RMS value of the current
––
●
●
with wire setting range
(bimetal measuring function),
phase 3
BS
Slave pointer function for the
●
––
––
measurement of the RMS
value IB
BS1
Slave pointer function for the
––
●
●
measurement of the RMS
value IB, phase 1
BS2
Slave pointer function for the
––
●
●
measurement of the RMS
value IB, phase 2
BS3
Slave pointer function for the
––
●
●
measurement of the RMS
value IB, phase 3
F
Frequency of the input
●
●
●
variable
Sym- Meaning
Application
bols
(see table 4)
A11
A34
A24 /
…
A44
A16
P
Active power of the system
●
●
●
P1
Active power phase 1
––
––
●
(phase-to-neutral L1 – N)
P2
Active power phase 2
––
––
●
(phase-to-neutral L2 – N)
P3
Active power phase 3
––
––
●
(phase-to-neutral L3 – N)
PF
Active power factor
●
●
●
cos
ϕ
= P/S
PF1
Active power factor phase 1,
––
––
●
P1/S1
PF2
Active power factor, phase 2,
––
––
●
P2/S2
PF3
Active power factor, phase 3,
––
––
●
P3/S3
Q
Reactive power of the
●
●
●
system
Q1
Reactive power, phase 1
––
––
●
(phase-to-neutral L1 – N)
Q2
Reactive power, phase 2
––
––
●
(phase-to-neutral L2 – N)
Q3
Reactive power, phase 3
––
––
●
(phase-to-neutral L3 – N)
S
Apparent power of the
●
●
●
system
S1
Apparent power, phase 1
––
––
●
(phase-to-neutral L1 – N)
S2
Apparent power, phase 2
––
––
●
(phase-to-neutral L2 – N)
S3
Apparent power phase 3
––
––
●
(phase-to-neutral L3 – N)
LF
Power factor of the system
●
●
●
LF1
Power factor phase 1
––
––
●
LF2
Power factor phase 2
––
––
●
LF3
Power factor phase 3
––
––
●
QF
Reactive power factor
●
●
●
sin
ϕ
= Q/S
QF1
Reactive power factor
––
––
●
phase 1, Q1/S1
QF2
Reactive power factor
––
––
●
phase 2, Q2/S2
QF3
Reactive power factor
––
––
●
phase 3, Q3/S3
EA
Energy meter 1
●
●
●
EB
Energy meter 2
●
●
●
EC
Energy meter 3
●
●
●
ED
Energy meter 4
●
●
●
Where c.t’s and/or v.t’s are used for measurement, the values
are referred to the primaries of the transformers.