![Gossen MetraWatt METRA HIT 1A Operating Instructions Manual Download Page 19](http://html.mh-extra.com/html/gossen-metrawatt/metra-hit-1a/metra-hit-1a_operating-instructions-manual_2247235019.webp)
GMC-I Messtechnik GmbH
19
5
Technical Characteristics
Voltage Measuring Ranges
1)
0 dB
0.775 V in the range of 1.5 V
; 0 dB
1 mW at 600
Ω
Input resistance in relation to voltage
for : 20.0 k
Ω
/V
for
:
4.0 k
Ω
/V
METRA HIT 1A: Current Measuring Ranges
Voltage
Output
1
)
Internal Resistance approx.
0.15 V —
3.15
k
Ω
—
0.50 V —
10.00
k
Ω
—
1.50 V
–15 ... + 6 dB
31.50 k
Ω
6.50 k
Ω
5.00 V
– 5 ... + 16 dB
100.00 k
Ω
20.00 k
Ω
15.00 V
+ 5 ... + 26 dB
315.00 k
Ω
65.00 k
Ω
50.00 V
+15 ... + 36 dB
1.00 M
Ω
200.00 k
Ω
150.00 V
+25 ... + 46 dB
3.15 M
Ω
650.00 k
Ω
500.00 V
+35 ... + 56 dB
10.00 M
Ω
2.00 M
Ω
Current
Voltage Drop approx.
50.00 μA
0.158 V
—
0.50 mA 1.15
V
1.00
V
5.00 mA 1.25
V
1.25
V
50.00 mA 1.25
V
1.25
V
500.00 mA 1.85
V
1.85
V
5000.00 mA 1.73
V
1.73
V