Printed in China
2016 V 1.0
GSM SMS
Page 1: ...Printed in China 2016 V 1 0 GSM SMS ...
Page 2: ...Zone Setup Connecting Wireless Accessories Wireless Accessories Enrolling Delete All Enrolled Accessories Zone Setup Connecting Wired Accessories Linkage Electronic Facilities Programming System by SMS Text SMS Text Operation 06 11 15 17 20 22 23 15 23 24 25 29 34 34 Frequently Asked Questions 49 02 Restore System to Default Setting 47 Specification Quick Start Guide 04 13 14 24 31 Download APP Th...
Page 3: ...el when a door or window is opened Wireless Door Window Sensor Wireless Remote Control The remote control allow you to control your security system when you are away or come back When emergency happens press the emergency button to send an emergency signal to the control panel The control panel is the brain of security alarm system which is able to communicate with all wireless sensors When alarm ...
Page 4: ...Control Panel Installation Please remove all supplied contents from packaging as below If there re anything missing please return to your place of purchase Control Panel P I R Motion Detector Remote Control Bracket for Motion Detector Power Adapter User Manual Plastic Plugs Screws Batteries 3M Double sided Tape Wall mounted Bracket Door Window Sensor Quick Start Guide 5 4 ...
Page 5: ... 1 Control Panel Installation Note User have to store the phone number after SIM Card is inserted When detectors are triggered the alarm will be activated The system will notify family members by sending out SMS alert or calling Even the phone charge is overdue the alarm will be activated when detectors are triggered 1 Gently open the battery bay cover 2 Insert a SIM card fix it 3 Insert power ada...
Page 6: ...etector has been enrolled to the system 7 Silence the siren by pressing disarm button on remote control 4 6 1 4 3 Using Door Sensor Enrolling Test 1 Open the case and install the battery properly 2 Arm the system by pressing arm button on remote control 3 Depart the transmitter and magnet 4 If the alarm is activated the door sensor has been enrolled to the system 5 Silence the siren by pressing di...
Page 7: ...es to recognize the location Central Monitoring Station Setup Cellular communication by SMS Text or Apps easy control Up to 50pcs sensors 10 remote controls can be expanded by auto learning 2 wired zone especially for smoke gas vibration detector IR beams etc Text to preset 3 groups of SMS number auto dial 5 groups of phone number and CMS number Internal siren sound and mute mode for optional Imme...
Page 8: ... Password 0 Arm Password 1 Stay Arm Password 2 Using Mobile Apps Please enter keyword Ontips to download the apps from the App Store or Google Play Fill in the Control Panel Name Sim Card Number of control panel to enter the user interface Note There s no command for sending emergency call Status LED Indication Power Signal LED Indication AC Power On Green LED normally on AC Power Off Green LED of...
Page 9: ...se Method 1 Send a text of to phone number of control panel the system will reply an operation guide message to your phone You can control the system by using the command codes listed Please refer to page 34 for command codes Method 2 Please enter keyword Ontips to download the apps from the App Store or Google Play Fill in the Control Panel Name Sim Card Number of control panel to start programmi...
Page 10: ...ED left flashes once the siren beeps once to enter the arming state Any detectors triggered will activate the system to alarm immediately The system simultaneously calls the preset phone numbers Once Exit delay function is set system will be delayed arming accordingly When you arm the system in case of delay time less than 10 seconds control panel will beep once every second While delay time more ...
Page 11: ...e to cross movement than to direct movement The performance of the detector is optimal when detection direction is across the walking direction of intruders 3 Press the clip insert the battery properly and then close the cover 4 Using screws to fix the bracket of detector on the wall attach the detector to the bracket 5 Keep LED indicator at the right direction The fixing height isabout 2 2 2m fro...
Page 12: ...or Window Sensor can be installed on doors windows and any other objects that open and close The sensor transmits signal to control panel when the magnet mounted near the sensor is moved away The tamper protection ensures that sabotage attempts to move the sensor will result in an alarm activation 2 3 4 5 7 6 1 Transmitter 2 LED Indicator 3 Magnet 4 Battery Compartment 5 Zone Jumper 6 Buzzer 7 Tam...
Page 13: ... light flashes once the accessories have been enrolled before If three beeps are heard and LED light flashes once the storage is full Wireless Accessories Enrolling Note Wireless siren is not included as wireless accessory For specific details Please refer to the manual of siren If accessories zones are changed you have to reconnect the accessories to the control panel User can not trigger accesso...
Page 14: ...reless Zone 4 2 1 Delete Enrolled Wireless Accessories Press and hold the enroll button for 6 seconds until one beep is heard All enrolled wireless accessories will be deleted Press the tamper switch continuously for 5 times until one long beep is heard All preset number will be deleted at once and the system is restored to default setting successfully Restoring operation will not delete the enrol...
Page 15: ...y Delay Time is set accessories in single delay zone will be delayed for arming and alarming Home Mode Zone accordingly But accessories in Normal Zone Home Mode Zone and 24 Hour Zone will not be delayed Single Delay Zone Wireless Zone 3 Note PIR Motion Detector is set in stay home mode zone as default Door Window Sensor is set in Normal Zone 4 as default Wireless Zone 5 Wireless Zone 6 Wireless Zo...
Page 16: ...our Zone Setup No matter what state the alarm system is in once the accessories in 24 Hour zone are triggered the control panel will get the signal and alarm immediately Note It s highly recommended to set the smoke detector gas detector and perimeter detectors at 24 Hour Zone Wireless Zone 15 Wireless Zone 16 29 28 ...
Page 17: ... to GND block the Positive Pole to N O block Then link COM block and 12V block Linkage AC Electronic Facilities It is able to turn on electronic facilities like lights or fences to deter the intruder immediately in the event of alarm Note The max output of Built in Battery is 8 4V When wired siren is connected please make sure the power supply is on for working properly Ground Power Output for Wir...
Page 18: ...y Change Access Code Language Settings Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 24H Zone 15 24H Zone 16 7 8 9 10 11 Alarm Type Wired Sensor Type Keyfob SMS Alert Supervion for Door Sensor Change Keyfob Name Uesr ID Report Upload GSM Signal Strength Monitor 33 32 ...
Page 19: ... command code for example to store phone numbers password 5 Programming System by SMS Text Operation Note Users have to store the phone number after Sim Card is inserted so that the control panel can be remotely controlled and when alarm is activated it will send and receive messages Disarm 0 Arm Away 1 Arm Stay 2 Status Inquiry 3 Alarm Management 4 Store Phone Numbers 5 Change Zone Name 6 Other S...
Page 20: ...formation Inquiry IMEI No IMEI is International Mobile Equipment Identity number consist of 15 digits electronic serial number which is unique to identify valid devices Every alarm panel will be assembled with an unique IMEI number to make sure it s original from manufacturer Send this operation code from your cell phone Send this operation code from your cell phone Send this operation code from y...
Page 21: ...ou will receive Send this operation code from your cell phone 1234 5 Send this operation code from your cell phone SMS reply you will receive SMS 1 2 3 TEL 1 2 3 4 5 CMS 1 2 Note Phone numbers which haven t been stored will be refused Forward copy and paste this text message to control panel phone number Add phone numbers that you want to control over Phone numbers includes 3 SMS numbers where you...
Page 22: ...71 72 73 74 75 76 77 User can set the siren to be audible or silent when it s alarming Choose the types of wired sensors after they are connected When system alarms user can choose to get SMS alerts or not if someone disarm it by keyfob Change the password 78 79 Set exit entry delay time for accessories in single delay zone It allows users to leave or enter home within the programmed time without ...
Page 23: ...r the hurry up notification Once an entry is detected it will allow the user to enter and disarm the system within the programmed entry time 712 713 Central Monitoring Station Setup Report Upload On Report Upload Off Default Password 714 User ID User ID changed successfully 1 Program User ID for Central Monitoring Station Note The user ID is the Central Station Account number which should be 4 dig...
Page 24: ...l send SMS notification GSM Signal GSM Signal Strength Monitoring ON GSM Signal Strength Monitoring OFF Default Bad GSM Signal Change Language 1234 8 81 English 82 Customized Language 83 Customized Language Send this operation code from your cell phone Language has been changed to English Language has been changed to Language has been changed to 81 82 83 SMS reply you will receive Electrical Facil...
Page 25: ...elow numbers Disarm the system press 0 Arm the system in the away mode press 1 Turn on on site siren press 7 Turn off on site siren press 8 Turn on AC facility press 5 Turn off AC facility press 6 Monitor the site press key Press escape or hang up to exit Phone Remote Control Other System Alert SMS Control Panel AC Power Lost Please Enter Correct Command Code Control Panel AC Power Recovery Emerge...
Page 26: ...el s Power Supply GSM Working Frequency GSM WCDMA SMS Security Alarm System Standby Current Alarm Maximum Current Internal Battery Backup Internal siren Allowed Amount of Expandable Wireless Accessories Radio Frequency Housing Material ABS plastic Operation Condition Humidity 80 non condensing 10pcs remote controls 50pcs wireless accessories Size L x W x H 850 900 1800 1900MHz 300mA Max Output DC ...
Page 27: ...sword 75 to active it Frequently Asked Questions 1 I want to know which room alarms how to setup There re 6 wireless zone 2 emergency zone and 2 wired zone name of wired zone cannot be changed Step 1 Set the wireless sensors in same room at the same zone following the instruction image of zone jumper setup on manual Page20 21 Step 2 Sending the text command password 6 to change the zone name for d...
Page 28: ...on area C Movement should cross the detection and within 8 meters range D The detector enters sleeping mode to save power after first detection If there s no movement within 4 minutes the detector goes back to the working state If there s detection occurs within 4 minutes the time detector goes back to working state will be added accordingly 3 If the PIR motion detector pet immunity No The PIR sup...