MAINTENANCE AND REPAIR
PUMP DISASSEMBLY AND
REASSEMBLY
Review all SAFETY information in Section A.
Follow the instructions on all tags, labels and
decals attached to the pump.
This pump requires little service due to its rugged,
minimum‐maintenance design. However, if it be
comes necessary to inspect or replace the wearing
parts, follow these instructions which, unless
otherwise specified, are keyed to the sectional
view (see Figure E‐1) and the accompanying parts
key. Refer to the separate parts list accompanying
your pump for part numbers.
In the following text, minor headings are followed
by a number in parenthesis. This number repre
sents the assembly for the item being discussed as
identified in Figure E‐1.
Before attempting to service the pump, shutdown
incoming power and lock it out or disconnect the
power source to ensure that it will remain inopera
tive.
For power source disassembly and repair, consult
the literature supplied with the power source, or
contact your local power source representative.
This manual will alert personnel to
known procedures which require spe
cial attention, to those which could
damage equipment, and to those which
could be dangerous to personnel. How
ever, this manual cannot possibly pro
vide detailed instructions and precau
tions for each specific application or for
every situation that might occur during
maintenance of the unit. Therefore, it is
the responsibility of the owner, installer
and/or maintenance personnel to en
sure that applications and/or mainte
nance procedures not addressed in this
manual are performed only after estab
lishing that neither personal safety nor
pump integrity are compromised by
such applications or procedures.
Do not attempt to service the pump un
less all power to the power source has
been disconnected; otherwise, serious
personal injury or death could result.
PUMP DISASSEMBLY
This pump may be used to handle liq
uids which may cause serious illness or
injury through direct exposure or
emitted fumes. Wear protective cloth
ing, such as rubber gloves, face mask
and rubber apron, as necessary, before
disconnecting or servicing the pump or
piping.
In the instructions
which follow the
FRONT
is the
head assembly end of the pump and the
REAR
is
the drive (or backhead) end of the pump.
NOTE
It is strongly recommended that gaskets and O‐
rings be replaced whenever the pump is reas
sembled.
Preparing for Disassembly
The pump should be removed from the system pip
ing and drained for servicing. Close all valves in the
suction and discharge lines to isolate the pump.
Position drain pans and/or absorbant material un
der and around the pump suction and discharge
ports. Disconnect the suction and discharge hose/
piping.
Remove the hardware securing the pump to the
power source and separate the power source and
pump assembly. Retain all connection parts such
as shaft keys, etc.
Use a hoist and sling with sufficient capacity to
position the pump in a suitably sized drain pan or
surround the pump with absorbant material. Some