background image

LEDI 6 – LEDI 6/S 

4 /8 

 
EXISTING VERSIONS 
 

 

Autonomous version 

Built-in quartz time base: frequency 3.6864 MHz, stability ±0.2 s/24 hours between 20° and 25°C. 

 

Minute impulse receiver, parallel connection 

24 V reversed impulse every minute. 
Impulse duration: 0.1 s. 
Impulse consumption: 6 mA/24 V. 

 

Half-minute impulse receiver, series connection 

Series connection with external 39 ohm shunt. 
Reversed impulse every half-minute. 
Impulse duration: 0.1 s. 
Impulse consumption: 1.25 V. 
Current strength: 60-120 mA. 

 

AFNOR NFS 87-500 code receiver 

Nominal input level: 2.2 V DC. 
Input impedance: 3.5 kOhms. 
Minimum input voltage: 70 mV DC. 

 

869 MHz Radio version 

 

The clock synchronizes itself automatically following the emitting period of the emitter. Waiting the reception,  
2 points between the hours and the minutes stay off until one reception was received. Then these points 
have a second period blink except a 59th second off during 3 minutes. 

  
2 - MOUNTING 
 

Standard case

 (cf. fig. 1 - fig. 2 - fig. 3)

 

- Prepare the wall support for attaching the bracket. Leave at least 60 mm between the top of the case and 
the ceiling.  
- Fix the bracket on the wall support using two 4 mm dia. screws. 
- Hook the case over the bracket. 

 

Flush-mounted case

 (fig. 5)

 

- Prepare the wall support. LEDI 6: 335 x 151 x 75 mm.    

LEDI6/S: 415 x 198 x 75 mm 

- Position the support clip in the wall recess. 
- Clip the clock on to its support. 

 

Watertight case

 (fig. 6 - fig. 7)

 

- Prepare and drill the wall support. 
- Fix the “LEDI’s support” using three M5 screws 
- Hang and clip the clock on to its support, taking care to bring out the wires at the top. 
 

3 - CONNECTIONS (fig. 4) 
 

- Connect the 230 V/50-60 Hz mains supply to the 3-conductor cable. 
- Flip the battery switch 

SW1 to the ON

 (lower) position after connecting the clock.  

N.B. If the hours and minutes remain unlit, wait a few minutes for the internal battery to be recharged.

 

 

3.1 - WATERTIGHT case 

All connections are made at the back, without having to open the case. Cables should be connected as 
shown by the identification marks. 
 7-conductor 

cable 

 

Ascii 232 version :RXD : Blue  

Ascii 422/485 version :RX- / TX- : Blue 

      TXD :  Pink 

 

 

 

  RX+ / TX+ : Pink 

      GND : Brown  

 

 

 

  GND : Brown 

 

Impuls or AFNOR NFS87500 version : Green / Grey 

 

Pip version : White/ yellow 

Summary of Contents for LEDI 6

Page 1: ...LEDI 6 LEDI 6 S USER MANUAL STANDARD FLUSH MOUNTED or WATERTIGHT CASE...

Page 2: ...7 65 135 Made in France N serie Impuls 230V SW1 OFF ON PROG B1 B2 B3 B4 230V Fig 1 B1 Input PROG 320 Fig 2 Fig 3 Fig 4 2 x diam 4 2 3 1 2 1 Use the lever to make the connections input MOUNTING PRINCIP...

Page 3: ...ED numerical display of hours minutes seconds S option Height of figures 60 mm Inclination of figures 10 Legibility 25 metres Power supply 230 V 10 50 60 Hz 115 V AC or 48 V AC optional Consumption 6...

Page 4: ...pport for attaching the bracket Leave at least 60 mm between the top of the case and the ceiling Fix the bracket on the wall support using two 4 mm dia screws Hook the case over the bracket Flush moun...

Page 5: ...from 1 to 9 seconds 2 adjustment of temperature display time from 1 to 9 seconds 3 adjustment of hours 4 adjustment of minutes SYNCHRONISATION If the minutes have not been modified one press on PROG w...

Page 6: ...Imax 50 Ma In case of an open collector output the ground is connected to 1 6 2 12 HOUR OPTION This version has the same characteristics as the standard version except that the display goes from 01h0...

Page 7: ...this case the clock is completely slaved to the other 6 4 3 Two directional mode In this mode the ASCII coded time message is transmitted after reception of a recognition character D configuration 24...

Page 8: ...LEDI 6 LEDI 6 S 8 8 WARNING ISOLATE BEFORE REMOVE COVER FOR19 A 005D GORGY TIMING RC 74 B Registered trademark and design...