INSTALLATION OF THE HEAT PUMP
Installation must be carried out in accordance with the manufacturer’s instruction by a qualified installation expert.
Indoor unit - boiler
The indoor unit – boiler must be installed in a frost-free room. When selecting the place of installation, pay
attention to the solidity of the wall – can it take the weight of the heat pump together with the weight of the water
inside the boiler? It is recommended to choose a place that enables installation with minimum gas pipeline length.
During installation, please bear in mind the minimum distances from the wall, ground and ceiling – see Figure 1.
The condensate outlet from the heat pump is placed on the bottom left side in the form of a plastic tube with an
external diameter of ø18 mm. Condensate appears very seldom.
Fig. 1: Connection and installation dimensions of the indoor unit -
boiler [mm]
A
B
C
D
E
TC120SNE
1201
645
100
100
G 1/2
TC150SNE
1416
845
100
100
G 1/2