Indoor unit – connection terminals in receptacles
Fig. 13: Connection terminals in receptacles A and B
Connecting the indoor and the outdoor unit
A connecting signal cable is enclosed with the heat pump to connect the indoor and the outdoor unit. The cable is
used to transfer data from the temperature sensors. The supply cable that connects the indoor and the outdoor
unit is not enclosed! The cable must comply with the minimum quality standard H05RN-F with a cross sectional
area of 1.0 to 1.5 mm
2
. On the outdoor side, the connecting cables must be additionally protected from the
elements and other potential dangers.
Connecting the cable to the indoor unit
On the upper side of the lid, unscrew two nuts (Fig. 14a), pull out four pegs (Fig. 14b), and take the lid off the
indoor unit.
Connect the cables to the connecting clamps as marked with numbers on the connecting panel of the indoor
unit.
When reattaching the lid use the new pegs enclosed.
14a
14b
Fig. 14: Removing protective lid from the indoor unit