Outdoor unit - aggregate
Mount the outdoor unit – aggregate in a horizontal position using a nut and bolt with a diameter of ø10 or ø8 to a
concrete or other solid base.
Please take notice of the following warnings:
If an awning is built to protect the unit from direct sunlight or rain, please make sure the air flow is not restricted.
Make sure you leave more than 30 cm at the back and left side of the unit.
At the front side, leave more than 200 cm of clearance.
At the connection (right) side and above the unit, please make sure to leave more than 60 cm of space.
Make sure there are no animals or plants nearby that could be harmed by the air coming out of the unit.
Take into account the weight of the outdoor unit and choose an area where noise and vibrations will not be an
issue.
Please make sure you select a spot where the outdoor unit will not bother the neighbours.
If the outdoor unit – aggregate is mounted to a roof, make sure to level the unit.
Please make sure the roof structure and anchoring method are appropriate for the unit.
When mounting the unit on the roof, please take into account the local regulations.
Fig. 2: installation dimensions of the outdoor unit – the aggregate
Installation of the outlet element
Insert a gasket into the outlet elbow, insert the outlet element into the opening in the lower container of the
outdoor unit and turn by 90 degrees to attach the element. Connect a pipe extension to the outlet element (not
included) in case of water outlet from the outdoor unit.
Fig. 3: Installing the outlet element
If the outdoor unit – aggregate is mounted on a roof construction or outside walls, this can cause excessive noise
and vibrations. In this case the unit can generate excessive noise while operating. If the outdoor unit – aggregate
is mounted directly on a roof there is a chance that the installation process will cause the roof to leak.
To reduce the transfer of noise and vibrations through walls into the premises where this could be a problem
(bedrooms, rest areas), please take the following measures.
Make sure the place of wall penetration is properly insulated.
Make sure the outdoor unit – aggregate is mounted in an appropriate way.