Instructions for use, installation and connection
60
Flexible hose connection
In case the appliance is connected by means of a flexible
hose, the position A of the hose is not permissible.
In case the connection hose is made of metal, position A is
permissible.
Beginning of operation
Start using the appliance in accordance with the instructions
for use. Lit up all burners and check the stability of the flame
with high and low setting. Adjust air intake if necessary.
After that, take time and explain the operation and control of
the appliance to the user and read with him the instructions for
use.
Liquefield gas connection
9
Pipe coupling liquefied
10
Gasket (certain models only)
11
Connection R1/2
Nozzle chart
Type of gas,
pressure
Auxiliary burner
Normal burner
Large burner
Triple burner
Wobe number
Standard
Fast
max
min
max
min
max
min
max
min
max
min
Natural gas H
Wo=45,7
÷
54,7 MJ/ m
3
,
Nominal heat
input (kW)
1
0,36
1
0,36
1,90
0,46
3
0,76
3,5
1,56
Natural gas E ,
Consumption (l/h)
95,21
34,4
95,21
34,4
180,9
43,8
285,64
72,4
333,2
148,5
Natural gas E+
Wo=40,9
÷
54,7 MJ/m
3
Nozzle mark
(1/100mm)
77
-
78
-
104
-
129
-
140
•
G20,
p=20mbar
Nozzle code
162081
162082
162083
162084
162085
Liquid gas 3+, 3B/P
Wo=72,9
÷
Nominal heat
input (kW)
1
0,36
1
0,36
1,90
0,46
3
0,76
3,5
1,56
87,3MJ/m
3
Consumption (g/h)
71,7
26,2
71,7
26,2
138,1
33,4
215,0
55,3
254,5
113,4
G30
p=30 mbar
Nozzle mark
(1/100mm)
50
29/24
50
29/24
69
33/26
87
43/33
93
57/57
Nozzle code
162162
162162
162164
162165
162166
•
Built-in regulation knobs are intended for liquefied gas. In case of natural gas (municipal gas line) they need to be set according to
the required gas flow (unscrew for maximum 1,5 turn from the tightened position).
Nozzle code for minimum varies with different manufacturers. First digit from the pair represents IMIT, and the second one
COPRECI.
Burner heating input is indicated according to the maximum caloric value of gas Hs.
Warning: this work may be performed only by qualified expert, authorized by the gas distribution company or by the
authorized service!
Conversion to another type of gas
•
For the conversion procedure the appliance need not be
pulled out from its location.
•
Before starting to work on conversion, disconnect the
appliance from the mains.
•
Replace the existing nozzles of declared nominal heat input
with adequate nozzles for the new type of gas (see table).
•
Adjust the nozzle for the minimum heat input rate as long as
it requires to arrive at the minimum heat input.
•
Never unscrew nozzles for minimum heat input rate for more
than 1,5 turn.
•
After the conversion is done,
stick the new sticker with the
actual gas specifications of the appliance over the old one.
•
Check that electrical cables, thermostat probe and thermal
elements are located away from the gas jet!
Setting elements
Elements for regulation of cooking burners are accessible
when the control panel is removed.
•
Remove the cooktop grid and burner crowns with caps.
•
Remove the control buttons.
•
Unscrew bottom tightening screws from the control panel
and remove the panel.