Instructions for use, installation and connection
61
Cooking zone burner (fig. 1 )
1
1
Burner crown cap
2
Burner crown with
burner cap support
3
Thermal probe
4
Ignition plug
5
Nozzle
Triple-ring burner (fig. 2)
5
nozzles
Safety gas faucet (fig. 3)
13
Setting screw for
minimum heat input
rate
Non-safety gas faucet (fig. 3a)
13
Setting screw for
minimum heat input
rate
Elements to be replaced or reset when altering the type of
gas
Cooking zone burner
Fig. number
Element code
Nominal heat input
1, 2
5
Minimum heat input
3, 3a
13
Electrical connections
Open the connection box using the screwdriver, as
shown by the drawing on the cover.
Connection to the mains power can be done only by
the authorized service center or by qualified
personnel!
Wrong connection may damage the parts of appliance and
render your warranty viod!
Connecting voltage of the user’s installation (230 V against N)
must be verified by qualified electrician using the appropriate
tester.
Connector bridges must be positioned in accordance with
the installation connection!
•
Prior connecting the appliance, check whether the voltage of
the rating plate corresponds to the actual voltage of home
installation.
•
Length of the power lead must be at least 1.5 m so that the
appliance can be connected to power before pushing it
against the wall.
•
Length of the earthing lead must be longer than the others,
so that it is strained later than the tension power leads in
case of accidental pullout from the socket.
Procedure
•
Using the screwdriver open the connection box cover at the
back of the appliance. You can do so by releasing two
catches, as shown on the connection box cover.
•
Power cable must be guided through the relief device,
protecting it from pulling out. If the relief device has not been
fixed yet, fix it in such way to hook the power cable to the
device housing at one end.
•
Now connect the power cable in accordance to
one
of the
options shown on the figure. In case of different installation
voltages, the connection bridges should be rearranged
accordingly!
•
Tighten the relief device and close the connection box cover.
NOTE:
In some connection boxes the connector bridges are placed
between contacts 4 and 5, and in the others they are stored at
a designated place within the box. These boxes have the
connection screws already in open position so they need not
be unscrewed. During the tightening procedure you will hear a
faint “click”, meaning that the tightening screw should be
fastened tightly all the way.
Colored power leads
L1, L2, L3 = exterior power leads under tension. Usual colors
are black, black, brown.
N = neutral lead
Usual color is blue.
Watch for the correct N-connection!
PE = earthing (protective lead)
Lead color is green-yellow.
2