10) REPLACING THE INJECTORS
The burners can be adapted to different types of
gas by mounting injectors suited to the type of gas
in question. To do this, first remove the burner tops
using a wrench “B”. Now unscrew injector “A” (see
fig. 13) and fit a injector corresponding to the
utilized type of gas in its place.
It is advisable to strongly tighten the injector in
place.
After the injectors have been replaced, the
burners must be regulated as explained in
paragraphs 9. The technician must reset any
seals on the regulating or pre-regulating devices.
The envelope with the injectors and the labels
can be included in the kit, or at disposal to the
authorized customer Service Centre.
For the sake of convenience, the nominal rate table
also lists the heat inputs of the burners, the
diameter of the injectors and the working pressures
of the various types of gas.
BURNER ARRANGEMENT ON THE HOT PLATE
CONVERSIONS
TABLE
1
ULTRA RAPID
G 30 - BUTANE28 - 30
225
90
1400
3100
G 31 - PROPANE37
222
90
1400
3100
G 20 - NATURAL
20
295
121 Y
1400
3100
2
RAPID
G 30 - BUTANE28 - 30
204
83
750
2800
G 31 - PROPANE37
200
83
750
2800
G 20 - NATURAL
20
267
117 Y
750
2800
BURNERS
N°
DESCRIPTION
GAS
NORMAL
PRESSURE
NORMAL
RATE
INJECTOR
DIAMETER
NOMINAL HEAT
INPUT (W)
mbar
g/h
l/h
1/100 mm
Min.
Max
4
SEMIRAPID
G 30 - BUTANE28 - 30
127
68
500
1750
LEFT BACK
G 31 - PROPANE37
125
68
500
1750
G 20 - NATURAL
20
167
98 Z
500
1750
5
AUXILIARY
G 30 - BUTANE28 - 30
73
51
400
1000
G 31 - PROPANE37
71
51
400
1000
G 20 - NATURAL
20
95
75 X
400
1000
3
SEMIRAPID
G 30 - BUTANE28 - 30
102
58
500
1400
RIGHT FRONT
G 31 - PROPANE37
100
58
500
1400
G 20 - NATURAL
20
133
85 Y
500
1400
28
FIG. 13
Summary of Contents for GT64AB1-236661
Page 65: ...COD 04027CEGOA 04027CETR 22 01 2009 KULLANIM KILAVUZU GT64AB1 236661 GT76AB1 236654 ...
Page 79: ...79 AYGITIN GAZ AYARI ÝLE ÝLGÝLÝ TEKNÝK BÝLGÝLER ...
Page 96: ...DATE TEHNICE PRIVIND REGLAREA ALIMENTĂRII CU GAZ AAPARATULUI 96 ...
Page 98: ...98 ...
Page 99: ...99 ...
Page 100: ...100 ...