STEP 5B - REMOTE MOUNTED SLIDE HANDLE INSTALLATION (CONTINUED)
5B.4
Once the wire rope, coil cord footer
and G360™ swivel are aligned,
replace the 16mm shoulder bolt
thereby capturing the wire rope, coil
cord footer and G360™ swivel
(
diagram 5B1
, page 9).
5B.5
Thread the coil cord connector into the
G360™ connector (
diagram 5B1
,
page 9).
5B.6
Thread M12 jam nut onto the 16mm
shoulder bolt.
5B.7
Check that the coils of the coil cord
are centered around the wire rope
when properly installed.
5B.8
A pilot hole is provided for the locking pin. Attach tooling to
G360™ utilizing M16 thread. The tool bolt/rod thread should be
beyond pilot hole of shaft when fully engaged. Using a #21 drill
bit, drill through the tool bolt/rod thread and out the other side of
G360™ shaft. Hammer pin into place thereby locking tooling to
G360™ (
diagram 5B2
).
5B.9
Assemble the remote mounted slide handle inside the remote mount
bracket using the hardware provided (
diagram 5B3
).
Note:
This step is
best completed on a workbench prior to mounting handle to tooling.
5B.10
Attach the remote mounted handle with bracket to the tooling. Assure
that the mounting arrangement does not affect the operating function
of the slide handle.
5B.11
Connect the extension cable from the G360™ to the remote mounted slide handle. Securely clamp
the remote mount coil cord extension cable to the tooling as needed.
5B.12
Continue to Step 6 on page 17.
WARNING
Remote mounted G-Force® handles must be mounted at both the
top and bottom of the handle assembly. Failure to mount the remote
mounted handle at top and bottom can result in poor performance
and/or premature component failure.
Diagram 5H.
Tooling Installation.
Diagram 5B2.
Tooling Installation.
Diagram 5D.
Remote Mounted Slide Handle, Exploded View
2x M16 Hex Head Cap Screw
2x M16 Lockwasher
2x M16 Flatwasher
Diagram 5B3.
Remote
Mounted Slide Handle,
Exploded View.
2X M16 Hex
x 30mm Lg.
Head Cap Screw
2X M16
Lockwasher
2X M16
Flatwasher
Slide Handle,
Remote Mounted
Configuration
Remote
Mount Slide
Handle
Bracket
CAUTION
Take care to avoid looping excess cable at locations where the loop could catch on foreign
objects.
CAUTION
All cables used in a remote mounted handle configuration must be properly clamped and/or strain-
relieved to prevent premature failure of the G-Force® or customer tooling.
10
9/18 - Rev. U