background image

Figure 2.3.2-1

Figure 2.4.1-1

Figure 2.4.1-2

Figure 2.4.1-4

Figure 2.4.1-3

Figure 2.3.2-2

Figure 2.3.2-3

Figure 2.3.2-4

C

2.4 ELECTRICAL WIRING CONNECTION

2.4.1 BATTERY WIRING CONNECTION

2.3.2  MOUNTING

Note: 
•BAT cable must be tightly crimped into the 

connectors

•There will be a click sound if connectors are inset 

correctly into BAT plugs

Note: 
•Please use BAT plugs and connectors in 

GoodWe accessory box

•BAT cable should be standard, 4-6mm

2

 

BAT cable

Note

For the compatible lithium batteries (Pylon/BYD) connection, please refer to battery connection 

part in BT quick installation instructions.

Prepare BAT cables and BAT plugs
(Figure 2.4.1-2)

Battery wiring connection steps as below:

Screw the cap on and plug onto inverter side (Figure 2.4.1-4)

Connect BAT cables to BAT connectors
(Figure 2.4.1-3)

Note: 
•There will be a click 

sound if connectors 
are inset correctly 
into BAT plugs.

OFF

7mm

7mm

Wall bracket Expansion pipe

self-tapping
screw

•Use the right BAT plugs in the accessory box.
•Use the tin-plated cables with a conductor cross section of 4 to 6 mm² (AWG 10) because the 

maximum battery current is 25A. Battery cable requirements are as (Figure 2.4.1-1).

Make sure battery switch is off and battery nominal voltage meet BT series’ specification before 
connecting battery to inverter and make sure inverter is totally isolated from AC power.

[4]

Please following requirements and step bellow  strictly. Use improper wire may cause bad
contact and high impedance, which is dangerous to the system.

•Please be careful against any electric shock or chemical hazard. 
•Make sure there is an external DC breaker (

40A) connected for battery without build-in DC 

breaker.

The inverter is suitable for mounting on concrete or other non-combustible surface only.

• Please use the mounting bracket as a template to drill 

4 holes on right positions. (10mm in diameter, and 
80mm in depth) (Figure 2.3.2-1)

• Use expansion bolts in accessory box and fix the 

mounting bracket onto the wall tightly.

Note: Bearing capacity of the wall must be higher than 

25kG, otherwise may not be able to keep inverter 
from dropping.

Carry the inverter by holding the heating sink 
on two sides and Place the inverter on the 
mounting bracket. (Figure 2.3.2-2)

Note: Make sure the heat sink on inverter is 

right joint with mounting bracket.

Ground cable shall be connected to 
ground plate on grid side (Figure 
2.3.2-3)

A lock could be used for anti-theft if it is 
necessary for individual requirement. 
(Figure 2.3.2-4)

Grade

A

B

C

Description

Outside diameter insulation

Conductor core section

Conductor core length

Value

5.5-8.0 mm

4-6 mm

2

7 mm

Remember that this inverter is heavy! Please be careful when lifting out from the package.

[2]

08

07

Step 1

Step 1

Step 3

Step 2

Step 2

Step 3

Step 4

Summary of Contents for BT Series

Page 1: ...RETORFIT JIANGSU GOODWE POWER SUPPLY TECHNOLOGY CO LTD No 90 Zijin Rd New District Suzhou 215011 China www goodwe com service goodwe com 340 00330 00 PV Master APP SEMS Portal APP SEMS Portal website www semsportal com LinkedIn Company s offical website ...

Page 2: ... 3 MOUNTING 2 3 1 SELECT MOUNTING LOCATION 2 3 2 MOUNTING 2 4 ELECTRICAL WIRING CONNECTION 2 4 1 BATTERY CONNECTION 2 4 2 ON GRID BACK UP CONNECTION 2 4 3 SMART METER CT CONNECTION 2 5 DRED EARTH FAULT ALARM 2 5 1 DRED CONNECTION 2 5 2 EARTH FAULT ALARM 3 1 WI FI CONFIGURATION WI FI RELOAD 3 2 GEI AUTO TEST INSTRUCTION 3 3 CEI AUTO TEST FUNCTION 4 1 ERROR MESSAGE AND TROUBLESHOOTING 4 2 DISCLAIMER...

Page 3: ...f high voltage and electric shock Components of the product can be recycled This side up The package must always be transported handled and stored in such a way that the arrows always point upwards Danger of hot surface No more than six 6 identical packages being stacked on each other Product should not be disposed as household waste The package product should be handled carefully and never be tip...

Page 4: ...ements of local grid authorities or companies like AS 4777 and AS NZS 3000 in Australia Prohibit to insert or pull the AC and DC terminals when the inverter is running Before any wiring connection or electrical operation on inverter all DC and AC power must be disconnected from inverter for at least 5 minutes to make sure inverter is totally isolated to avoid electric shock The temperature of inve...

Page 5: ...ound inverter following the values in Figure 2 3 1 3 2 3 MOUNTING 2 3 1 SELECT MOUNTING LOCATION 2 1 UNACCEPTABLE INSTALLATIONS INSTALLATION INSTRUCTIONS 02 Pin Terminal 12 User Manual 1 Quick Installation Guide 1 2 2 PACKING LIST BACK UP CANNOT CONNECT IN PARALLEL ONE BATTERY BANK CANNOT BE CONNECT TO MULTIPLE INVERTERS INVERTER BATTERY INPUT CANNOT CONNECT TO INCOMPATIBLE BATTERIES BACK UP SIDE ...

Page 6: ...battery to inverter and make sure inverter is totally isolated from AC power 4 Please following requirements and step bellow strictly Use improper wire may cause bad contact and high impedance which is dangerous to the system Please be careful against any electric shock or chemical hazard Make sure there is an external DC breaker 40A connected for battery without build in DC breaker The inverter i...

Page 7: ...ut AC cable through terminal cover follow the sequence as on the right Figure 2 4 2 4 Note Please use the terminals in GoodWe components box Press the 10 connectors on cable conductor core tightly Figure 2 4 2 5 Note Make sure cable jacket is not locked within the connector 1 Connect the assembled AC cables into AC terminals with fastening torque about 2 0 2 5N m Note Connecting Back up terminals ...

Page 8: ... contact GoodWe s after service Smart Meter CT Connection Diagram Figure 2 4 2 7 Smart Meter LED Indications Declaration For Back Up Overload Protection Inverer will restart itself as overload protection happens The preparation time for restarting will be longer and longer max one hour if overload protection repeats Take following steps to restart inverter immediately Decrease Back up load power w...

Page 9: ...ing anti reverse function which could be different for different grid tied inverters Connection Diagram as below Figure 2 4 2 8 1 Put the cable through the plate as shown in Figure 2 5 1 4 2 Wiring from the No 5 and 6 holes respectively Connect DRED terminal to the right position onto the inverter Figure 2 5 1 5 Step 3 2 For Remote Shutdown Step 1 Step 2 Step 4 Screw this plate off from inverter F...

Page 10: ... Depends on household loads 1 For batteries with attached breaker the external DC breaker could be omitted 2 Please use CT A for L1 CT B for L2 and CT C for L3 And follow House K Grid L direction to do the connection Otherwise there will be an error reminded by APP Battery To Battery AC Breaker DC Breaker AC Breaker AC Breaker Loads Grid PE N L3 L2 L1 To Smart Meter AC Breaker SmartMeter AC Breake...

Page 11: ...ke the system work as customer needs 2 Monitor and check performance of the hybrid system 3 Wi Fi configuration Please download PV Master OPERATION INSTRUCTIONS from https en goodwe com Note 1 Please make sure the password Encryption Method Algorithm is right the same with the router s 2 If everything is right well the Wi Fi LED on inverter will change from double blink to quartic blink then to so...

Page 12: ... inverter check if it still happens If not it is just an occasional situation Otherwise contact GoodWe immediately Try to restart inverter check if it still happens If not it is just an occasional situation Otherwise contact GoodWe immediately Try to restart inverter check if it still happens If not it is just an occasional situation Otherwise contact GoodWe immediately Try to restart inverter che...

Page 13: ...al even not connect to router then please try to reload Wi Fi please refer to BT user manual page 17 Q Why cannot connect Solar WiFi signal on my phone A It is the character of the Wi Fi module that it can connect to only one device at a time If the signal is connected to another device at the time for some reason then you cannot connect to the signal About Battery Operation Q Why battery does not...

Page 14: ... receive data from inverter or server normally it is because communica tion problem such as battery communication and communication between inverter and the APP About Smart Meter and Power Limit Function Q How to Act Output Power Limit function A For BT system the function could be realized by 1 Make sure Smart Meter connection and communication well 2 Turn on Export Power Limit function and set t...

Page 15: ...ell please install the inverters in one day after unpacking otherwise please seal all unused terminals holes not allowed to keep any terminals holes open confirm there is no risk to have water dust in Maintemamce The inverter requires periodically maintenance details as below Make sure inverter is totally isolated from all DC and AC power for at least 5 mins before mainte nance Heat sink Please us...

Page 16: ...nd other plug connected equipment Applies to a fixed equipment downstream and including the main distribution board Examples are switchgear and other euiquipment in an industrial installation Applies to equipment permanently connected at the origin of an installation uostream of the main distribution board Examples are electricity meters primary over current protection equipment and other equipmen...

Reviews: