RAM PRO XL 0321
6
Operation
•
Connect water hose to water inlet of no more than 100 p.s.i.. Use clean water
supply. Make sure screen washer is in place.
•
Make sure cap is on dispenser and machine is off so water does shoot out
of dispenser. One can add more Tablets with the machine unactivated for 5
seconds or more. When pressure in the dispenser vents through shaft, the cap
can then be removed.
•
Open water supply line. Water will flow through the flexible shaft assembly
only when the machine is running. DO NOT RUN THE UNIT DRY!!
•
Plug electric cord into an outlet with appropriate voltage and amperage.
Test the GFCI by pushing the “Test” button and then the “Reset” button. The
“POWER ON” light should light up. If not, push the “Reset” button and
try again.
•
Make sure drive manifold of the machine is parallel to floor.
•
Select proper size cleaning tool and attach to end of flexible shaft. Never use a
tool larger than I.D. of tube.
Note:
Most tubes are rolled outward at tube sheet. Always measure I.D.
beyond roll or consult manufacturer’s manual for tube O.D. and gauge.
•
Remove foot switch from storage compartment and place it in a convenient
position for operation.
•
Uncoil flexible shaft completely and arrange the shaft in the largest loop
possible to minimize “helixing” (shaft coiling on itself under power).
•
GTC-701 thru -704 - Position the stop on the flexible shaft so when the shaft is
inserted into the tube up to the stop the tip of the cleaning tool is clear of the
end of the tube.
•
Check the direction of the spiral in the tube and start with the appropriate
direction using the foot pedal. “FORWARD” on the machine is clockwise
brush rotation when facing the tube. Use the opposite rotational direction
(“REVERSE”) when extracting the tool from the tube.
•
Insert brush/tool into the tube. Press “FORWARD” foot pedal. Feed the shaft
into the tube. DO NOT FORCE SHAFT DOWN TUBE - Allow machine to do
the work. If resistance is felt, back off 2"-3" (0.50 - 0.75 m) and feed shaft again
until it goes easily. If resistance is too great, use a smaller cleaning tool or
check tube for blockage.