WX-950
Installation Manual
4-11
Rev. C
Table 4-1. Error Messages (Continued)
ERROR
PROBABLE CAUSE
CORRECTIVE ACTION
ERROR 24. MIC KEY STUCK.
Mic key (inhibit line) has been
asserted for at least 60 seconds.
Weather mapping is inhibited.
a. Press any key to continue.
b. Check inhibit line wiring.
c. If inhibit line not used, leave it
unconnected.
d. Check power to comms radio; if
off, the radio may be asserting the
inhibit line.
e. Contact Customer Service.
ERROR 25. SW VER ERROR
Incompatible software versions
Continued operation is not possible.
Contact Customer Service.
ERROR 26 - 34. Processor Fault.
Main processor
Continued operation is not possible.
Contact Customer Service.
ERROR 35. Processor Fault.
Main or DSP processor
Weather mapping is inhibited.
a. Press any key to continue.
b. Contact Customer Service.
ERROR 36. Processor Fault.
Main or DSP processor
Weather mapping is inhibited.
a. Press any key to continue.
b. Contact Customer Service.
ERROR 38. Invalid Configuration.
The system configuration is set up
for synchro and stepper heading
signals instead of synchro or
stepper.
Stepper & XYZ Selected.
Heading Stabilization is not available.
a. Press any key to continue.
b. Check jumper selections in mating
connector assembly (refer to
paragraph 2.8, table 2-6). Make
sure only one heading type is
selected (jumper open).
c. Contact Customer Service.
ERROR 39. High Temperature.
Processor temperature is outside of
specifications (i.e., >80°C for
approximately five minutes).
a. Press any key to continue.
b. Make sure WX-950 internal fan is
operating.
c. Check for adequate ventilation.
d. Perform user initiated self-test
from Menu to determine if
condition still present. May occur
briefly under very hot conditions.
e. Contact Customer Service.
ERROR 40. Processor Fault.
Main processor
Press any key to continue.
Contact Customer Service.
ERROR 41. Processor Fault.
Main or DSP processor
Continued operation is not possible.
Contact Customer Service.
ERROR 42. Processor Fault.
Main processor
Continued operation is not possible.
Contact Customer Service.
Heading flag indicator (FLG) appears in
weather screens.
Heading Flag
a. It is normal for the heading flag
indicator to be present if the
heading flag line is asserted
b. The heading flag indicator will also
be present if a heading related
fault is present (Error 22,23).
Summary of Contents for Stormscope Series II
Page 16: ...WX 950 Installation Manual 1 8 Rev C This page intentionally left blank...
Page 34: ...WX 950 Installation Manual 2 19 Rev C Figure 2 11 Heading Flag KCS55 Connection...
Page 37: ...WX 950 Installation Manual 2 22 Rev C This page intentionally left blank...
Page 65: ...WX 950 Installation Manual A 6 Rev C This page intentionally left blank...