WX-950
Installation Manual
2-2
Rev. C
c.
WX-950 Test Cable P/N 803-10951-001. The bench test cable may be purchased directly from Goodrich
Avionics System, or one may be fabricated (unterminated cable may be purchased from Electronic
Cable Specialists - ECS P/N 312207) from the details provided in figure 2-1.
Figure 2-1 Test Cable
2.3.2 Test Procedure
CAUTION
Before connecting/disconnecting cables, ensure that all power is removed.
1.
Connect the equipment as shown in figure 2-2.
Figure 2-2 Test Setup
2.
Rotate the OFF/BRT knob clockwise about 180 degrees. After approximately 15 seconds, the
initialization screen will be displayed. During initialization, the system runs a series of self-tests to
ensure that all functions are operating properly. These tests are designed to check the antenna,
processor, and associated hardware.
3.
If no faults are detected, at completion of the self-test an “ ALL TESTS PASSED” message will be
displayed.
Summary of Contents for Stormscope Series II
Page 16: ...WX 950 Installation Manual 1 8 Rev C This page intentionally left blank...
Page 34: ...WX 950 Installation Manual 2 19 Rev C Figure 2 11 Heading Flag KCS55 Connection...
Page 37: ...WX 950 Installation Manual 2 22 Rev C This page intentionally left blank...
Page 65: ...WX 950 Installation Manual A 6 Rev C This page intentionally left blank...