20
SPLIT SYSTEM HEATING PERFORMANCE
SSZ160241A*
Liq
Suct
Liq
Suct
Liq
Suct
Liq
Suct
Liq
Suct
Liq
Suct
Liq
Suct
Liq
Suct
Liq
Suct
Liq
Suct
Liq
Suct
65
266
64
277
72
288
79
298
87
309
95
320 102 331 110 342 118 353 125 364 133 375 141
70
286
64
297
71
308
79
319
87
330
94
341 102 351 110 362 117 373 125 384 133 395 140
75
306
64
318
71
329
79
340
86
351
94
362 102 373 109 384 117 395 125 406 132 417 140
65
257
63
267
71
278
79
288
86
299
94
309 101 320 109 330 117 341 124 351 132 362 140
70
276
64
287
71
297
79
308
87
318
94
329 102 340 110 350 117 361 125 371 132 382 140
75
296
64
307
72
318
79
329
87
339
95
350 102 361 110 371 118 382 125 392 133 403 141
65
251
63
261
71
271
78
281
86
291
94
301 101 312 109 322 117 332 124 342 132 353 140
70
269
64
280
71
290
79
300
87
311
94
321 102 331 109 341 117 352 125 362 132 372 140
75
289
64
299
72
310
79
320
87
331
95
341 102 352 110 362 118 372 125 383 133 393 140
Label p/n: 0140R00187-A
740
850
960
Liquid Valve & Compressor Suction Pressure
Outdoor Air Dry Bulb Temperature (ºF)
32
Indoor
Air Flow
Rate
37
42
47
57
67
Indoor Return
Air Dry Bulb
Temperature
(ºF)
17
27
Pressures show n are for most popular match indoor unit WITH NO FROST ON OUTDOOR COIL. Due to factors like airflow , charge, indoor coil & f rost, pressures w ill vary
significantly. Liquid (small) service valve pressures should be ± 20 psig & suction (access port) pressures should be ±5 psig of the values listed in this chart.
62
52
22
HEATING MODE PRESSURE CHART
Calculations are based on nominal CFM and 70 °F indoor dry bulb.
AMPS = Outdoor unit amps (comp.+fan)
*Note: Shaded area is AHRI Rating Conditions at 47°F outdoor ambient temperature
KW = Total system power
EXPANDED PERFORMANCE DATA
MODEL: SSZ160241A* / CA*F3636*6A* + TXV / MBE1600**-1
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
30.2
28.6
26.9
25.1
24.0
23.3
21.6
19.9
18.7
17.3
15.9
15.0
14.4
13.0
11.5
10.0
8.6
7.0
Delta T
31.9
30.2
28.4
26.6
25.4
24.6
22.9
21.1
19.8
18.3
16.8
15.9
15.3
13.7
12.2
10.6
9.0
7.4
KW
1.79
1.75
1.72
1.68
1.66
1.65
1.62
1.58
1.68
1.64
1.60
1.58
1.56
1.52
1.48
1.45
1.41
1.37
AMPS
8.4
7.8
7.3
6.9
6.7
6.6
6.2
5.9
5.7
5.4
5.2
5.1
5.0
4.7
4.4
4.2
3.9
3.5
COP
4.93
4.76
4.57
4.37
4.22
4.13
3.91
3.69
3.26
3.08
2.91
2.79
2.71
2.49
2.27
2.03
1.78
1.50
EER
16.9
16.3
15.6
14.9
14.4
14.1
13.4
12.6
11.2
10.5
9.9
9.5
9.3
8.5
7.7
6.9
6.1
5.1