4
www.goodmanmfg.com
SS-GPG13M
SS-GPG13M
www.goodmanmfg.com
5
P
roduct
S
PecificationS
P
roduct
S
PecificationS
s
peCiFiCations
—
gpg1336-42
GPG1336
045M41B*
GPG1336
090M41B*
GPG1342
070M41B*
GPG1342
070M41D*
GPG1342
090M41B*
GPG1342
090M41D*
Cooling Capacity
Total BTU/h
35,000
35,000
40,500
40,500
40,500
40,500
Sensible BTU/h
27,800
27,800
30,800
30,800
30,800
30,800
SEER / EER
13.0 / 11.0
13.0 / 11.0
13.0 / 11.0
13.0 / 11.0
13.0 / 11.0
13.0 / 11.0
Decibels
78
78
78
78
78
78
AHRI Reference #s
5360601
5360601
5360602
6531559
5360602
6531559
Heating Capacity
Input BTU/h
46,000
92,000
69,000
69,000
92,000
92,000
Output BTU/h
36,700
73,600
55,000
55,000
73,600
73,600
AFUE
80
80
80
80
80
80
Temperature Rise Range
30 - 60
45 - 75
35 - 65
35 - 65
45 - 75
45 - 75
No. of Burners
2
4
3
3
4
4
Orifice Size (Natural/Propane)
43 / 55
43 / 55
43 / 55
43 / 55
43 / 55
43 / 55
Evaporator Motor
Type
PSC
PSC
PSC
PSC
PSC
PSC
Wheel (D x W)
10” x 9”
10” x 9”
10” x 10”
10” x 10”
10” x 10”
10” x 10”
Indoor Nominal CFM
1,250
1,250
1,300
1,300
1,300
1,300
Motor Speed Tap (Cooling)
Med
Med
Medium
Medium
Medium
Medium
RPM/Amps (Cooling)
910/3.06
910/3.06
910/3.06
910/3.06
910/3.06
910/3.06
Horsepower
1/3
1/3
1/3
1/3
1/3
1/3
Evaporator Coil
Face Area (ft²)
4.33
4.33
5.67
5.67
5.67
5.67
Rows Deep/Fins per Inch
4/14
4/14
4/14
4/14
4/14
4/14
Piston Size (Cooling)
0.068
0.068
0.072
0.072
0.072
0.072
Filter Size (ft²)
4.2
4.2
4.7
4.7
4.7
4.7
Drain Size (NPT)
¾”
¾”
¾”
¾”
¾”
¾”
Refrigerant Charge (oz.)
70
70
81
99
81
99
Condenser Fan / Coil
Horsepower - RPM
1/4 - 830
1/4 - 830
1/4 - 1100
1/4 - 1100
1/4 - 1100
1/4 - 1100
Diameter / # of Blades
22” / 3
22” / 3
22” / 3
22” / 3
22” / 3
22” / 3
Outdoor Nominal CFM
2,400
2,400
3,500
3,500
3,500
3,500
Face Area (ft²)
8.8
8.8
11.32
15.36
11.32
15.36
Rows Deep/Fins per Inch
2/27
2/27
1/27
1/24
1/27
1/24
Compressor
Quantity / Type
1 / Scroll
1 / Scroll
1 / Scroll
1 / Scroll
1 / Scroll
1 / Scroll
Stage
Single
Single
Single
Single
Single
Single
Compressor RLA/LRA
16.7/79.0
16.7/79.0
17.9 / 112
17.9 / 112
17.9 / 112
17.9 / 112
Electrical Data
Voltage-Phase (60 Hz)
208/230-1
208/230-1
208/230-1
208/230-1
208/230-1
208/230-1
Indoor Blower FLA/LRA
3.06/4.1
3.06/4.1
3.0 / 4.1
3.0 / 4.1
3.0 / 4.1
3.0 / 4.1
Outdoor Fan FLA/LRA
1.5 / 3.0
1.5 / 3.0
1.4/ 2.9
1.4/ 2.9
1.4/ 2.9
1.4/ 2.9
Total Unit Amps
21.2
21.2
22.3
22.3
22.3
22.3
Min. Circuit Ampacity
25.4
25.4
26.8
26.8
26.8
26.8
Max. Overcurrent Protection
40 amps
40 amps
40 amps
40 amps
40 amps
40 amps
Entrance Size Power Supply
1⅛”
1⅛”
1⅛”
1⅛”
1⅛”
1⅛”
Entrance Size Control Voltage
⅞”
⅞”
⅞”
⅞”
⅞”
⅞”
Operating / Ship Weights (lbs)
459 / 482
459 / 491
462 / 485
493 / 515
462 / 488
496 / 520
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
² Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
Note: Always check the S&R plate for electrical data on the unit being installed.