24
www.goodmanmfg.com
SS-GPG13M
SS-GPG13M
www.goodmanmfg.com
PB
P
roduct
S
PecificationS
P
roduct
S
PecificationS
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without
notice or without incurring obligations. © 2014 Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.
Wiring
is subject
to change. Al
wa
ys
refer to the wiring
diag
ram
or the
unit
for
the most up-to-da
te
wiring
.
⚠
W
arning
High
Voltage:
Disconnect
all power
bef
or
e
ser
vicing
or
installing
this
unit.
Multiple
power
sour
ces ma
y be pr
esent.
Failur
e to do so ma
y cause pr
operty damage, per
sonal injur
y, or dea
th.
⚡
HPS
BL/PK BLUE/PINK
HIGH PRESSURE SWITCH
HPS
4
NOTE 2
H
F
RCCF C
T2 T1
T5
RUN CAPACITOR FOR COMPRESSOR/FAN
RCCF
5
IIC
1
2
3
N
L
VENT MOTOR RELAY
VMR
FUSE
F
T3
T4
2 STAGE COOLING W
ITH ECONO
MIZER
THERMOSTAT FIELD WIRING
R
G
RD
GR
C
Y2
YL
BL
Y1
PU
G
R
C
Y
0140G01234 REV A
W
W
WH
INSTALLER/SERVICEMAN
-
GAS PRESSURE
FLAME ROLLOUT
AUX. LIMIT OPEN
FLAME SENSOR
BAD SWITCH
GAS VALVE
CHECK FUSE ON CONTROL
CHECK INPUT POWER
REPLACE CONTROL
GAS FLOW
ANTI-CYCLE TIMER
MAIN LIMIT OPEN
STICKING GAS VALVE
BAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
PRESSURE SWITCH
CHECK
CHECK
OFF
ON
OR
OR
1 BLINK
3 BLINKS
6 BLINKS
2 BLINKS
4 BLINKS
5 BLINKS
FALSE FLAME SENSED
OUTPUT DELAY
OPEN LIMIT SWITCH
COMPRESSOR
WITHOUT INDUCER ON
PRESSURE SWITCH CLOSED
PRESSURE SWITCH
OPEN AUX. LIMIT
OPEN ROLLOUT
SWITCH
OPEN
SWITCH
IGNITION FAILURE
NORMAL OPERATION
NO POWER OR
INTERNAL CONTROL
FAULT
STATUS LIGHT
EQUIP. STATUS
CHECK
NO ECONOMIZER
WH
GR
RD
YL
BL
208-230/1/60
T4 - LOW SPEED
COOLING SPEED (YELLOW WIRE)
USE NEC CLASS 2 WIRE.
6. USE COOPER CONDUCTORS ONLY.
T5 - HIGH SPEED
T3 - HIGH SPEED
T2 - MED. SPEED
T1 - LOW SPEED
HEATING SPEED (WHITE WIRE)
SPEED AT MOTOR T1, T2 AND T3 TERMINALS.
SPEED AT MOTOR T4 AND T5 TERMINALS. CHANGE HEATING
4. FOR DIFFERENT THAN FACTORY SPEED TAP. CHANGE COOLING
3. CRANKCASE HEATER NOT SUPPLIED ON ALL UNITS.
IN RETURN AIR COMPARMENT.
5. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE
INSULATION AS ORIGINAL.(USE COPPER CONDUCTOR ONLY).
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF
VENT MOTOR
VM
COMPRESSOR
COMP
LINE VOLTAGE
FACTORY WIRING
OPTIONAL HIGH VOLTAGE
HIGH VOLTAGE
FIELD WIRING
LOW VOLTAGE
LOW VOLTAGE
BK BLACK
WIRE CODE
PK PINK
OR ORANGE
GR GREEN
BR BROWN
BL BLUE
RD RED
WH WHITE
YL YELLOW
PU PURPLE
ALS
CH
C
CM
COMPONENT LEGEND
CRANKCASE HEATER
CONTACTOR
CONDENSER MOTOR
AUXILLARY LIMIT SWITCH
GAS VALVE
GV
FS
GND
IGNITOR
PS
PLF
LS
IGN
IIC
EQUIPMENT GROUND
PRESSURE SWITCH
FEMALE PLUG/CONNECTOR
LIMIT SWITCH
INTEGRATED IGNITION CONTROL
FLAME SENSOR
TR
TRANSFORMER
ROLLOUT SWITCH
RS
EM
EVAPORATOR MOTOR
NOTE 7
NOTE 7
2
VMR
VMR
EM
3
1
C
D1
C
NOTE
TR
NOTE 3
L2
2
CH
T2
208-230/1/60
CM
C
L1
R
T1
C
S
COMP
C
1
SUPPLY VOLTAGE
L2
VM
IGN
FS
NOTES
GV
LS
RS
ALS
PS
L1
F
FS
3
5
6
12
10
8
7
9
ECON
IIC
4
4
3 2 1
5
6
PLF
C
Y/Y2
11
TO THERMOSTAT
Y1
W
G
R
EM
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:
THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
C
H
w
iring
d
iagraM
— gpg1348-60M41** (
Cont
.)