background image

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT.  MULTIPLE POWER SOURCES MAY BE PRESENT.  FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

WIRING DIAGRAMS

17

DE
HUM

WARNING:DISCONNECT
PROPERLY POLARIZED
SERVICING. WIRING
TO UNIT MUST BE
AND GROUNDED.
POWER BEFORE

DISCONNECT POWER
MUST BE PROPERLY
BEFORE SERVICING.
WIRING TO UNIT
POLARIZED AND
GROUNDED.

TO 115VAC/ 1Ø /60 HZ POWER SUPPLY WITH
OVERCURRENT PROTECTION DEVICE

115 VAC/ 1Ø /60 HZ

POWER SUPPLY WITH
PROTECTION DEVICE
OVERCURRENT

115kBTU MODELS
INDUCTOR COIL
70kBTU,90kBTU,
ONLY

DOOR

SWITCH

MANUAL RESET
AUXILIARY
LIMIT CONTROL

TWO-STAGE
INTEGRATED
CONTROL
MODULE

16 WIRE
ECM MTR
HARNESS

INDUCTOR COIL
70kBTU,90kBTU,
115kBTU MODELS
ONLY

BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
 DOOR OPEN)

1 FLASH   = SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED)

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE
    REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE
    RATING OF AT LEAST 105°C. USE COPPER CONDUCTORS ONLY.

YL YELLOW

OR ORANGE

VT VIOLET

GN GREEN

BK BLACK

BR BROWN

WH WHITE

BU BLUE

GY GRAY

RD RED

COLOR CODES:

LOW VOLTAGE (24V)

LOW VOLTAGE FIELD

HI VOLTAGE (115V)

HI VOLTAGE FIELD

NOTES:

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.

22314701  REV.00

40 VA
TRANS-
FORMER

STEADY ON = NORMAL OPERATION

2 FLASHES = LOW FIRE PRESSURE SWITCH STUCK CLOSED

3 FLASHES = LOW FIRE PRESSURE SWITCH STUCK OPEN

CONTINUOUS FLASHES = 115 VOLT AC POWER REVERSED

1

2

3

4

C

0

       INTERNAL TO

INTEGRATED CONTROL

JUNCTION

EQUIPMENT GND

115

VAC

24
VAC

 OVERCURRENT

PROT. DEVICE

TERMINAL

4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.

TWO STAGE
GAS VALVE

PM

C

HI

HOT

SURFACE
IGNITER

INDUCED

DRAFT

BLOWER

GND

RD

FLAME
SENSOR

NO

C

WH

BK

BR

AUTO RESET PRIMARY

LIMIT CONTROL

GN

GY

HIGH FIRE

PRESS. SWITCH

LOW FIRE

PRESS.
SWITCH

4 FLASHES = THERMAL PROTECTIVE DEVICE OPEN

SWITCH (PRESS.)

SWITCH (TEMP.)

FIELD SPLICE

FIELD GND

NO

C

FRONT COVER

PRESSURE SWITCH

MANUAL RESET ROLLOUT

LIMIT CONTROLS 

(SINGLE CONTROL ON 45 kBTU)

PK PINK

PLUG CONNECTION

BURNER COMPARTMENT

BLOWER COMPARTMENT

VT

IGNITER

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.

PK

YL

5 FLASHES = FLAME SENSED WITH GAS VALVE DE-ENERGIZED

6

7 FLASHES = LOW FLAME SENSE SIGNAL

7

8 FLASHES = CHECK IGNITER OR IMPROPER GROUNDING

8

1

2

1

2

3

NO

C

ID BLOWER
TWO-STAGE PRESSURE
SWITCH ASSEMBLY

OR

2 CIRCUIT
CONNECTOR

CIRCULATOR
BLOWER

5

 C

IRCU

IT

CON

NNECTOR

RD

GY

VT

BU

5

4

3

2

1

24 V THERMOSTAT  CONNECTIONS

12

11

10

7

8

9

6

5

4

1

2

3

NEUTRAL

HOT

24 V
3 A

CHAS

S

IS

 GROU

ND

9

 C
IRCU

IT

 C
O

NN

ECT

O

R

WH

WH

RD

RD

BK

BU

OR

GY

GY

OR

PK

VT

FUSE

TR (9)

GND (10)

MVL(7)

PS2 (2)

PS1 (12)

HLO (11)

HL1 (6)

TH (5)

MANUAL RESET ROLLOUT
LIMIT CONTROL(S)

AUTO RESET
PRIMARY LIMIT
CONTROL

GAS
VALVE

GND

C

NO

C

NO

PM

HI

C

R

W2

Y

G

C

TO
MICRO

FUSE 3 A

INTEGRATED CONTROL MODULE

2

4

V T

H

E

R

M

O

ST
A

T

 C

O

N

N

E

C

T

IO

N

S

24 VAC

40 VA
TRANSFORMER

115 VAC

FLAME SENSOR

HUMIDIFIER

ID
BLWR

INDOOR

AIR

CIRCULATOR

BLWR

ELECTRONIC

AIR CLEANER

LINE-H

LINE-N

EAC-H

EAC-N

IGN-H

HUM-H

IND HI

XFMR-H

HOT SURFACE

IGNITER

HUM-N

IN

T

E

G

R

AT
ED
 C
O

N

T

R

O

L

 M
O

D

U

L

E

INT
E

G

R

A

T

E

D

 CO

NT
R

O

L

 M
O

DUL

E

GND

DISCONNECT

L

N

WARNING:

MANUAL RESET AUXILIARY LIMIT
CONTROLS

FRONT COVER
PRESSURE SWITCH

LOW FIRE
PRESSURE
SWITCH

FP (3)

IND LO

IGN-N

W1

MVH (1)

MVC (8)

C

HIGH FIRE
PRESSURE SWITCH

NO

9 FLASHES = HIGH FIRE PRESSURE SWITCH STUCK OPEN

9

BK

WH

IND-N

WH

GN

YL

GY

VT

3

4

5

6

2

1

OR

BR

OR

VT

DIAGNOSTIC
LED

HEAT OFF DELAY
DIP SWITCHES

T-STAT SELECTOR

BR

YL

VT

3

2

1

VT

LO

HE
A

T

HU

M

XF
M

R

LI

N

E

PAR

K

CO

O

L

EAC

HI

HE
A

T

BK

Y

B/

C

G

R

W1

W2

TW

IN

/

YL

O

YL
O

BK

RD

WH

RD

WH

WH

RD

BK

WH

GN

GND

5

4
3
2

1

BK

YLO

GND

PK

GND

TO

L

N

BK

-1

DISCONNECT

WH-5

WH

BK

BK

JUNCTION BOX

JUN

C

TI

O

N

 BO

X

BU

PK

GY

24V HUM. 

24
V HU

M

.

XFMR-N

24V HUM.

2

4

V

 HU

M

IDI
F

IE

R

BU

WH

PK

GN

GND

MANUAL RESET ROLLOUT

LIMIT CONTROLS 

(SINGLE CONTROL ON 45 kBTU)

BU

NO

C

Wiring is subject to change. 

Always refer to the wiring diagram on the unit for the most up-to-date wiring.

Summary of Contents for GMV95 Series

Page 1: ...as provided in the Service Manual Refer to the appropriate Parts Catalog for part number information Copyright 2005 2007 Goodman Manufacturing Company L P RT6612012Rev 1 June2007 This manual is to be...

Page 2: ...his unit without such background may result in product damage personal injury or death WARNING WARNING Goodman will not be responsibile for any injury or property damage arising from improper service...

Page 3: ...vice that is not design certified by Goodman for use with this unit Serious property damage personal injury reduced unit performance and or hazardous conditions may result from the use of such non app...

Page 4: ...ic ignition device to light the burners and an induced draft blower to exhaust combustion products An interlock switch prevents furnace operation if the blower door is not in place Keep the blower acc...

Page 5: ...Electrical Connection Inlets Alternate 18 Coil Front Cover Pressure Tap 19 Coil Front Cover Drain Port 20 Drain Line Penetrations 21 Drain Trap 22 Blower Door Interlock Switch 23 Inductor NotAll Model...

Page 6: ...FLANGES AIR DISCHARGE AIR DISCHARGE Cabinet Size A B C D E 13 5 8 17 1 2 20 7 8 All dimensions are in inches 24 1 2 12 1 8 16 19 3 8 12 15 16 15 15 16 20 7 16 GMV950453BX GMV950904CX GMV950905DX GMV95...

Page 7: ...IRE LOW FIRE HIGH FIRE LOW FIRE HIGH FIRE LOW FIRE HIGH FIRE GMV950453BX GMV950704CX 0 10 0 10 20197308 0 30 0 75 11177113 PURPLE PINK 0 10 0 10 0 22 0 55 HAPS28 11177115 GREEN YELLOW GMV950905DX GMV9...

Page 8: ...GMV951155DX 2 ROLLOUT LIMIT SWITCHES Part Number 10123535 10123537 10123536 10123533 Open Setting F 150 140 180 200 GMV950453BX 2 GMV950704CX 2 GMV950905DX 2 GMV951155DX 2 AUXILIARY LIMIT SWITCHES Par...

Page 9: ...al slab only 6 R 22orR 410A 2 R 22 4 R 410A Refrigerant Revision A Revision Coil Matches Alarge array ofAmana brand coils are available for use with the GMV95 furnaces in either upflow or horizontal a...

Page 10: ...Permanent Minimum Filter Area in2 Based on 600 ft min filter face velocity Thermostat Man Auto Programmable Cool Heat Batt Powered Batt Bkup 1213406 Man Or Auto Yes 2 3 No No 1213407 Man Changeover Y...

Page 11: ...43 55 43 55 43 55 43 55 Number of Burners 2 3 4 5 Vent Connector Diameter inches 2 2 3 3 Combustion Air Connector Diameter inches 2 2 3 3 Shipping Weight lbs 133 133 172 184 Refer to airflow charts o...

Page 12: ...71 46 Plus 924 1331 46 Minus 540 778 52 Minus 828 1192 51 Normal 600 864 47 Normal 920 1325 46 Plus 660 950 43 Plus 1012 1457 42 Minus 585 842 48 Minus 900 1296 47 Normal 650 936 43 Normal 1000 1440 4...

Page 13: ...lus 880 Minus 720 Minus 720 Minus 990 Minus 990 Normal 800 Normal 800 Normal 1100 Normal 1100 Plus 880 Plus 880 Plus 1210 Plus 1210 Minus 900 Minus 990 Minus 1260 Minus 1260 Normal 1000 Normal 1100 No...

Page 14: ...oses only 6 Motor CFM minimum GMV95 Continuous Fan Speed Chart Cooling Speed Tap Adjust Tap CFM at 1 8 w c ESP Cooling Speed Tap Adjust Tap CFM at 1 8 w c ESP Minus 380 Minus 380 Normal 380 Normal 380...

Page 15: ...4 3 2 1 4 3 2 1 4 3 2 1 Ramping Profile Tap A Ramping Profile Tap B Ramping Profile Tap C Ramping Profile Tap D Ramping Profiles indicates factory setting 8 7 8 7 8 7 6 5 6 5 6 5 6 5 O N O F F O N O...

Page 16: ...30 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPU...

Page 17: ...L PROTECTIVE DEVICE OPEN SWITCH PRESS SWITCH TEMP FIELD SPLICE FIELD GND NO C FRONT COVER PRESSURE SWITCH MANUAL RESET ROLLOUT LIMIT CONTROLS SINGLE CONTROL ON 45 kBTU PK PINK PLUG CONNECTION BURNER C...

Page 18: ...CUT FOR 1 2 3 87 4321 87 4321 Intell Ignition TSTAT S4 S3 OFF ON S1 SINGLE TWO ON OFF YL PK VT HOUSING SIDES OF BLOWER AUXILIARY LIMITS PIN 1 PIN 2 BK WH GN GY OR BK WH PIN 6 SCROLL HOUSING GROUND TO...

Page 19: ...STAGE M P COM MV SWITCH ROLLOUT MVH W2 W2 HUM EAC NEU EAC AIR CLEANER ELECTRONIC INDUCER HUMN HUMIDIFIER W1 G Y R W1 G Y B C TR R TH 24 V A C XFMRN XFMR BLOWER CIRCULATOR HLI HLO PS1 PS2 MVL GND IGNN...

Reviews: