GM9S80-U Heating Airflow Data

Heating AIFLOW

MODEL

THER-

MOSTAT 

CALL

TAP 

#

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

CFM

CFM

GM9S80

0403AU

W/W1

F02

690

42

643

46

597

49

547

53

498

55

443

389

343

F03^

750

39

702

42

660

45

618

48

572

52

525

477

421

F04

876

34

832

36

794

37

758

39

716

41

678

641

598

F05

927

32

881

34

841

35

806

37

771

38

734

698

662

F06

1058

28

1015

29

976

30

945

31

915

32

881

849

818

F07

1116

27

1071

28

1036

29

1003

30

975

30

943

919

884

GM9S80

0603AU*

W/W1

F05

1060

42

1017

44

981

45

950

47

921

48

886

856

828

F06

1108

40

1068

42

1033

43

1003

44

972

46

942

914

882

F07^

1274

35

1233

36

1203

37

1174

38

1146

39

1118

1089

1065

GM9S80

0604AU*

W/W1

F02

1274

35

1228

36

1188

37

1147

39

1107

40

1064

1027

990

F03

1295

34

1256

35

1214

37

1181

38

1140

39

1100

1062

1024

F04^

1385

32

1337

33

1301

34

1260

35

1222

36

1186

1149

1114

F05

1454

31

1407

32

1372

32

1353

33

1325

34

1291

1255

1219

GM9S80

0804BU*

W/W1

F02^

1270

47

1223

48

1179

50

1139

52

1105

54

1066

1029

996

F03

1304

45

1254

47

1212

49

1173

51

1135

52

1104

1069

1032

F04

1367

43

1318

45

1277

46

1236

48

1199

49

1169

1135

1102

GM9S80

0805CU*

W/W1

F01

1280

46

1228

48

1178

50

1134

52

1086

55

1036

986

936

F02^

1401

42

1356

44

1313

45

1273

47

1234

48

1190

1145

1099

Notes:

• 

^ Default Heat Speed

TEMP 

RANGE

25 - 55

20 - 50

20 - 50

35 - 65

35 - 65

Summary of Contents for GM9S80-U Series

Page 1: ...n SCAQMD Rule 1111 and SJVUAPCD Rule 4905 AHRI Certified ETL Listed Installation upflow horizontal left or right Convenient left or right connection for gas and electrical service Heavy gauge steel ca...

Page 2: ...guration NOx M Upflow Horizontal N 40 NG J NOx C Downflow Horizontal X 40 NG J NOx U 14NG J NOx Motor Cabinet Width 9 Nine Speed ECM A 14 C 21 B 17 D 24 Gas Valve Maximum CFM C Two Stage 3 1200 CFM 4...

Page 3: ...System ICS Vent and combustion air diameters may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada National Stand...

Page 4: ...s Code NFPA 54 ANSI Z223 1 in the USA and the Canada National Standard of Canada CAN CSA B149 1 and CAN CSA B142 2 in Canada Note AMES80 approved for line contact in the horizontal position Model A B...

Page 5: ...8 1147 1107 1064 1027 990 F03 1295 1256 1214 1181 1140 1100 1062 1024 F04 1385 1337 1301 1260 1222 1186 1149 1114 F05 1454 1407 1372 1353 1325 1291 1255 1219 F06 1528 1485 1438 1409 1383 1349 1317 128...

Page 6: ...17 44 981 45 950 47 921 48 886 856 828 F06 1108 40 1068 42 1033 43 1003 44 972 46 942 914 882 F07 1274 35 1233 36 1203 37 1174 38 1146 39 1118 1089 1065 GM9S80 0604AU W W1 F02 1274 35 1228 36 1188 37...

Page 7: ...HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 Tem...

Page 8: ...RMER 115 VAC 24 VAC BK SENSOR YL FLAME BR 1 GAS VALVE 2 M C BL BLOWER COMPARTMENT AUTO RESET AUXILIARY LIMIT CONTROL PU BL AUTO RESET PRIMARY LIMIT CONTROL PU BK GND BLOWER DRAFT ID INDUCED 1 2 3 RD W...

Page 9: ...x 25 Side or 1 20 x 25 Bottom Note Larger filters may be used filters may also be centrally located Use 2 16 x 25 filters on side returns or 20 x 25 filter on bottom return if furnace is connected to...

Page 10: ...man Manufacturing Company L P reserves the right to discontinue or change at any time specifications or designs without notice or without incurring obligations 2021 Goodman Manufacturing Company L P H...

Reviews: