background image

06/03

*2P0603*

504,783M

*P504783M*

G60DF(X)

SERIES

Litho U.S.A.

504,783M
6/2003
Supersedes 504,574M

GAS FURNACE

E

 2003 Lennox Industries Inc.

Dallas, Texas, USA

WHAT TO DO IF YOU SMELL GAS:

Do not store or use gasoline or other

flammable vapors and liquids in the

vicinity  of  this  or  any  other  apĆ

pliance.
Installation  and  service  must  be

performed  by  a  qualified  installer,

service agency or the gas supplier.

D

Do not try to light any appliance.

D

Do not touch any electrical switch; do not

use any phone in your building.

D

Immediately call your gas supplier from a

neighbor's phone. Follow the gas supplier's

instructions.

D

If you cannot reach your gas supplier, call

the fire department.

FIRE OR EXPLOSION HAZARD.

Failure to follow safety warnings exactĆ

ly could result in serious injury, death,

or property damage.

WARNING

D

Leave the building immediately.

Summary of Contents for G60DF series

Page 1: ...must be performed by a qualified installer service agency or the gas supplier D Do not try to light any appliance D Do not touch any electrical switch do not use any phone in your building D Immediat...

Page 2: ...in and eye irritation To reduce exposure to this substance or for further information consult material safety data sheets available from address shown below or contact your supervisor Lennox Industrie...

Page 3: ...tion and the formation of carbon monoxide gas This toxic gas might then be distributed throughout the house by the furnace duct system WARNING The blower access panel must be securely in place when th...

Page 4: ...e 3 Honeywell VR8205 Gas Valve Turn knob on gas valve clockwise to OFF Do not force See figure 4 7 Wait five minutes to clear out any gas If you then smell gas STOP Immediately call your gas supplier...

Page 5: ...ned and sloped upward The vent connector must be physically sound without holes or excessive corrosion Inspect the furnace return air duct connection The duct must be sealed to the furnace and it must...

Page 6: ...t in your well being Planned Service You should expect a service technician to check the follow ing items during an annual inspection Power to the unit must be shut off for the service technician s sa...

Page 7: ...panel Top cap Control Panel Parts Transformer Two stage SureLight board Door interlock switch Circuit breaker Blower Parts Blower wheel Blower housing Motor Capacitor Motor mounting frame Blower hous...

Reviews: