background image

SS-GM9S80-U

www.goodmanmfg.com

5

GM9S80-U COOLING & CIRCULATION AIFLOW

COOLING & CIRCULATION AIRFLOW

MODEL

THERMOSTAT 

CALL

TAP #

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

CFM

CFM

CFM

CFM

CFM

CFM

CFM

CFM

GM9S80

0403AU*

Y1 / Y2 / G

F01

590

540

483

429

369

311

247

203

F02

690

643

597

547

498

443

389

343

F03

750

702

660

618

572

525

477

421

F04

876

832

794

758

716

678

641

598

F05^

927

881

841

806

771

734

698

662

F06

1058

1015

976

945

915

881

849

818

F07

1116

1071

1036

1003

975

943

919

884

F08^^

1238

1192

1158

1124

1098

1070

1044

1016

F09

1398

1357

1320

1293

1269

1239

1216

1194

GM9S80

 

0603AU*

Y1 / Y2 / G

F01

587

542

490

437

382

318

266

207

F02

685

638

590

543

498

448

392

339

F03

856

814

774

732

693

657

622

581

F04^

937

892

855

819

786

752

715

684

F05

1060

1017

981

950

921

886

856

828

F06^^

1108

1068

1033

1003

972

942

914

882

F07

1274

1233

1203

1174

1146

1118

1089

1065

F08

1374

1340

1306

1278

1254

1227

1201

1179

F09

1437

1395

1362

1332

1305

1278

1253

1228

GM9S80

0604BU*

Y1 / Y2 / G

F01

836

774

711

655

596

523

456

397

F02

1274

1228

1188

1147

1107

1064

1027

990

F03

1295

1256

1214

1181

1140

1100

1062

1024

F04

1385

1337

1301

1260

1222

1186

1149

1114

F05

1454

1407

1372

1353

1325

1291

1255

1219

F06^

1528

1485

1438

1409

1383

1349

1317

1285

F07

1619

1579

1551

1523

1495

1463

1430

1402

F08^^

1746

1697

1667

1642

1617

1593

1570

1540

F09

1772

1735

1698

1674

1645

1622

1598

1574

GM9S80

0804BU*

Y1 / Y2 / G

F01

722

658

599

534

458

386

330

268

F02

1270

1223

1179

1139

1105

1066

1029

996

F03

1304

1254

1212

1173

1135

1104

1069

1032

F04

1367

1318

1277

1236

1199

1169

1135

1102

F05^

1473

1429

1386

1355

1320

1289

1258

1224

F06

1560

1518

1476

1441

1409

1382

1350

1321

F07

1647

1605

1562

1531

1497

1467

1440

1408

F08^^

1720

1710

1674

1642

1611

1581

1553

1527

F09

1796

1759

1721

1687

1655

1628

1604

1578

GM9S80

0805CU*

Y1 / Y2 / G

F01

1280

1228

1178

1134

1086

1036

986

936

F02

1401

1356

1313

1273

1234

1190

1145

1099

F03

1593

1550

1512

1475

1436

1399

1360

1319

F04

1706

1662

1621

1586

1550

1515

1479

1444

F05^

1821

1775

1736

1703

1669

1636

1605

1576

F06

1836

1793

1757

1721

1689

1659

1628

1592

F07

1932

1888

1855

1825

1794

1762

1733

1701

F08^^

2184

2143

2110

2072

2048

2017

1989

1959

F09

2221

2178

2145

2109

2082

2053

2025

1992

Notes:

• 

Defaullt speed is F01 for circulation for all models

• 

^ Default Y1 speed 

• 

^^ Default Y2 speed

 

Summary of Contents for GM9S80-U Series

Page 1: ...n SCAQMD Rule 1111 and SJVUAPCD Rule 4905 AHRI Certified ETL Listed Installation upflow horizontal left or right Convenient left or right connection for gas and electrical service Heavy gauge steel ca...

Page 2: ...guration NOx M Upflow Horizontal N 40 NG J NOx C Downflow Horizontal X 40 NG J NOx U 14NG J NOx Motor Cabinet Width 9 Nine Speed ECM A 14 C 21 B 17 D 24 Gas Valve Maximum CFM C Two Stage 3 1200 CFM 4...

Page 3: ...System ICS Vent and combustion air diameters may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada National Stand...

Page 4: ...s Code NFPA 54 ANSI Z223 1 in the USA and the Canada National Standard of Canada CAN CSA B149 1 and CAN CSA B142 2 in Canada Note AMES80 approved for line contact in the horizontal position Model A B...

Page 5: ...8 1147 1107 1064 1027 990 F03 1295 1256 1214 1181 1140 1100 1062 1024 F04 1385 1337 1301 1260 1222 1186 1149 1114 F05 1454 1407 1372 1353 1325 1291 1255 1219 F06 1528 1485 1438 1409 1383 1349 1317 128...

Page 6: ...17 44 981 45 950 47 921 48 886 856 828 F06 1108 40 1068 42 1033 43 1003 44 972 46 942 914 882 F07 1274 35 1233 36 1203 37 1174 38 1146 39 1118 1089 1065 GM9S80 0604AU W W1 F02 1274 35 1228 36 1188 37...

Page 7: ...HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 Tem...

Page 8: ...RMER 115 VAC 24 VAC BK SENSOR YL FLAME BR 1 GAS VALVE 2 M C BL BLOWER COMPARTMENT AUTO RESET AUXILIARY LIMIT CONTROL PU BL AUTO RESET PRIMARY LIMIT CONTROL PU BK GND BLOWER DRAFT ID INDUCED 1 2 3 RD W...

Page 9: ...x 25 Side or 1 20 x 25 Bottom Note Larger filters may be used filters may also be centrally located Use 2 16 x 25 filters on side returns or 20 x 25 filter on bottom return if furnace is connected to...

Page 10: ...man Manufacturing Company L P reserves the right to discontinue or change at any time specifications or designs without notice or without incurring obligations 2021 Goodman Manufacturing Company L P H...

Reviews: