37
GMH95 & GCH9
GMH95 & GCH9
GMH95 & GCH9
GMH95 & GCH9
GMH95 & GCH9
©
2006 Goodman Manufacturing Company, L.P.
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
WIRING DIAGRAM
TO AVOI
D
P
O
SSI
B
L
E ELECTRI
CAL SHOCK,
PERSO
NAL I
N
JURY,
OR DEATH,
DI
SCO
N
NECT THE POW
E
R
B
E
FORE SE
RVI
C
IN
G.
WAR
N
IN
G
!
R
YL
YELLOW
OR
ORANGE
PU
PURPLE
GN
GREEN
BK
BLACK
BR
BROWN
WH
WHITE
BL
BLUE
GY
GRAY
RD
RED
COLOR
CODES:
LOW
VOLTAGE
(24V)
LOW
VOLTAGE
FIELD
HI
VOLTAGE
(115V)
HI
VOLTAGE
FIELD
NOTES:
1.
SET
HEAT
ANTICIPATOR
ON
ROOM
THERMOSTAT
AT
0.7
AMPS.
2.
MANUFACTURER'S
SPECIFIED
REPLACEMENT
PARTS
MUST
BE
USED
WHEN
SERVICING.
0140F00098
REV.--
OR
(MED
LOW)
BL
(MED)
RD
(LOW)
GAS
VALVE
C
PM
C
G
W
INTERNAL
TO
INTEGRATED
CONTROL
JUNCTION
EQUIPMENT
GND
FIELD
GND
DIAGNOSTIC
LED
2
CIRCUIT
CONNECTOR
HOT
SURFACE
IGNITER
OVERCURRENT
PROT.
DEVICE
IGNITER
TH
(3)
INTEGRATED
CONTROL MODULE
JUNCTION
BOX
LINE-H
LINE-N
XFMR-H
IN
TE
GRA
T
E
D
CO
NTR
O
L
MO
DUL
E
IN
TE
GRA
T
ED
CONTROL
MODU
L
E
GND
DISCONNECT
L
N
OVERCURRENT
PROTECTION
DEVICE
BR
GY
RD
BL
BK
4.
IF
HEATING
AND
COOLING
BLOWER SPEEDS
ARE
NOT
THE
SAME,
DISCARD
JUMPER
BEFORE
CONNECTING
BLOWER
LEADS.
UNUSED
BLOWER
LEADS
MUST
BE
PLACED
ON
"PARK"
TERMINALS
OF
INTEGRATED CONTROL
OR
TAPED.
3.
IF
ANY
OF
THE
ORIGINAL WIRE
AS
SUPPLIED
WITH
THE
FURNACE
MUST
BE REPLACED,
IT
MUST
BE
REPLACED
WITH
WIRING
MATERIAL
HAVING
A
TEMPERATURE
RATING
OF
AT
LEAST
105
TERMINAL
SWITCH
(PRESS.)
5.
UNIT
MUST
BE
PERMANENTLY
GROUNDED
AND CONFORM
TO
N.E.C.
AND
LOCAL
CODES.
PK
PINK
115
VAC
HOT
AND
PARK
TERMINALS
LINE-H
FLAME
SENSOR
FRONT
COVER
PRESSURE SWITCH
N
O
C
GY
BK
PLUG
CONNECTION
FIELD SPLICE
SWITCH
(TEMP.)
OR
24V THERMOSTAT
CONNECTIONS
GR
GND
115 VAC
24 VAC
BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)
DOOR
SWITCH
BK
GND
L
N
WH
JUNCTION
BOX
1
OR
ID
BLOWER
PRESSURE
SWITCH
HEAT-H
GND
WH
RD
WH
GND
BURNER
COMPARTMENT
BLOWER
COMPARTMENT
NOTE
4
SEE
N
O
COOL-H
BK
(HI)
BR
BR
CAPACITOR
YL
WH
YL
BL
PU
RD
OR
PK
BK
WH
WH
BLOWER
INDUCED
DRAFT
MANUAL
RESET
AUXILIARY
LIMITS
(1)
IN
UPFLOW
BLOW ER
DECK
(2)
IN
C'FLOW
BLOW ER
HOUSING
C
FS
HI
HE
AT
-H
LO
HE
AT
-H
IGNITER
HOT SURFACE
XFMR-N
IND
IGN
CIR-N
EAC-N
EAC-H
AIR
CLEANER
ELECTRONIC
BLWR
CIRCULATOR
BLWR
ID
FLAME SENSOR
115
VAC
TRANSFORMER
40
VA
24
VAC
GND
RO1
(5)
RO2
(11)
HLO
(1)
HLI
(7)
MVC (9)
GND (8)
TR (6)
OR
WH
WH
BL
YL
OR
RD
GR
BR
PK
PK
GY
WH
1
1
5
V
A
C
NE
U
T
RA
L
BK
BK
BK
GY
2
4
V THER
M
O
ST
A
T
CO
N
N
E
C
TI
ONS
MICRO
TO
C
G
Y
W
R
2
WH
OR
BL
YL
OR
OR
GY
PK
RD
OR
GY
WH
XFMR-N
XF
M
R
-H
TE
R
M
IN
A
L
S
GY
OR
GR
BR
1
2
3
12
11
10
9
8
7
6
5
4
°C.
USE
COPPER
CONDUCTORS
ONLY.
24 VAC
HUMIDIFIER
24
VAC
HUMIDIFIER
HUMIDIFIER
PSO
(4)
MVL(2)
PS
(10)
C
NO
C
NO
FRONT
COVER
PRESSURE
SWITCH
ID
BLOWER
PRESSURE
SW ITCH
0
C
7
6
5
4
3
2
1
OFF
= CONTROL FAILURE
STEADY ON = NORMAL OPERATION
1 FLASH =
2 FLASHES = PRESSURE SWITCH STUCK CLOSED
3 FLASHES = PRESSURE SWITCH STUCK OPEN
4 FLASHES = OPEN HIGH LIMIT
5 FLASHES = FLAME SENSE WITHOUT GAS VALVE
7 FLASHES = LOW FLAME SIGNAL
6 FLASHES =
CONTINUOUS/RAPID FLASHES = REVERSED 115 VA C POLARITY
CONTROL
MODULE
INTEGRATED
FUSE
ON
OFF
2ND
STAGE
DELAY
MODE
HEAT
OFF
DELAY
FS
1
2
3
HI
OR
OR
PM
GAS
VALVE
C
HI
MVH (12)
FACTORY
SETTINGS
SHOWN
*
*
*
*
SEE
NOTE 6
COOL-H
TO 115VAC/ 1 Ø /60 HZ POWER SUPPLY WITH
PU
ID-N
Y
6. TO RECALL THE LAST 5 FAULT S, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECO NDS WHILE IN
STANDBY (NO THE RMOSTAT IN PUTS)