48
1.
CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes
both filters are installed.
2.
All furnaces ship as high speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed.
3.
For most jobs, about 400 CFM per ton when cooling is desirable.
4.
INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
5.
The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded area indicates ranges
in excess of maximum external static pressure allowed when heating. The data for 0.6" w.c. to 0.8" w.c. is shown fo air conditioning purposes only.
6.
At higher altitudes, a properly de-rated unit will have approximately the same temperature rise at a particular CFM, while the ESP at that CFM will be lower.
GME95
BLOWER PERFORMANCE DATA
0.6
0.7
0.8
CFM
RISE
CFM
RISE
CFM
RISE
CFM
RISE
CFM
RISE
CFM
CFM
CFM
T1 - YELLOW
1.5
726
48
670
53
617
57
553
64
490
72
429
378
336
T2 - RED
2.0
905
39
860
41
812
43
761
46
712
49
663
610
574
T3 - ORANGE
2.5
112 1
31
1074
33
1039
34
998
35
959
37
923
882
839
T4 - BLUE
3.0
127 4
28
1239
28
1199
29
1166
30
1129
31
1096
1059
1021
T5 - BLACK
3.0
130 6
27
1261
28
1232
29
1195
29
1162
30
1132
1090
1057
T1 - YELLOW
1.5
714
80
667
79
604
87
548
96
484
109
422
367
325
T2 - RED
2.0
904
58
851
62
804
66
761
69
708
75
664
612
572
T3 - ORANGE
2.5
112 5
47
1075
49
1045
51
999
53
956
55
921
877
839
T4 - BLUE
3.0
131 2
40
1271
42
1228
43
1202
44
1165
45
1127
1087
1044
T5 - BLACK
3.5
142 3
37
1386
38
1354
39
1321
40
1278
41
1210
1134
1032
T1 - YELLOW
3.0
129 7
54
1253
56
1209
58
1161
61
1111
63
1067
1022
974
T2 - RED
3.5
150 7
47
1455
48
1422
49
1377
51
1334
53
1296
1251
1195
T3 - ORANGE
4.0
167 7
42
1637
43
1602
44
1562
45
1526
46
1484
1441
1324
T4 - BLUE
4.0
187 9
37
1842
38
1800
39
1762
40
1700
41
1566
1437
1319
T5 - BLACK
5.0
204 4
35
1967
36
1894
37
1795
39
1702
41
1578
1452
1320
T1 - YELLOW
3.0
133 1
66
1275
69
1206
73
1145
77
1080
81
1021
953
889
T2 - RED
3.5
151 2
58
1452
60
1392
63
1336
66
1279
69
1219
1175
1115
T3 - ORANGE
4.0
171 3
51
1666
53
1614
57
1569
56
1513
58
1468
1414
1364
T4 - BLUE
4.0
189 2
46
1845
48
1802
49
1752
50
1707
52
1656
1614
1577
T5 - BLACK
5.0
208 0
42
2038
43
2005
44
1960
45
1920
46
1879
1843
1791
0.3
Motor
Speed
Tons
AC at
0.5"
ESP
0.1
0.2
GME950603BX*
(MED-HI)
GME950805CX*
(MED-HI)
(CFM & TEMPERATURE RISE VS. EXTERNAL STATIC PRESSURE)
0.4
0.5
GME950403BX*
(MED-HI)
GME951005DX*
(MED-HI)
EXTERNAL STATIC PRESSURE (Inches Water Column)
Model
--------------
Heating Speed
As Shipped