Good Will Instrument PSS-2005 User Manual Download Page 9

    PSS-3203/2005 PROGRAMMABLE POWER SUPPLY

USER MANUAL

  12  

--Over Current Protection Setting:

Set to OCP SET window by pressing [MENU], Turn on/off the
OCP with the wheel knob and press [ENTER]. If OCP is on, when
the output current equals or exceeds the current value setting, the
output of the instrument will be off and get into over current
protection mode by displaying “OCP Error. Press “LOCAL” to
reset” on the display. Just press [LOCAL] to clear OCP status and
back to previous status.

5-3. The Display Contrast Setting

Set to Contrast Set window by pressing [MENU], modify its setting
value with the wheel knob and press [ENTER].

5-4. The Buzzer Setting

Set to Buzzer Set window by pressing [MENU], turn on or off the
buzzer with the wheel knob, then press [ENTER].

5-5.GPIB/RS232 Interface Setting

Set to Interface window by pressing [MENU]. If the GPIB is
displayed, the Address value window will be appeared, if the
RS-232 is displayed, the Baud Rate window will be appeared, then
using the wheel knob to modify the value and press [ENTER] to
complete the setting.

Note: The system will detect the interface used at present

automatically, and switch the detected interface over the
setting interface of GPIB or RS-232.

Example:

1)

 

If want to set the GPIB address value to 15:
Set to interface window by pressing [MENU], and adjust the
address value to 15 with the wheel knob and press [ENTER] to

    PSS-3203/2005 PROGRAMMABLE POWER SUPPLY

USER MANUAL

  13  

complete the setting.

2) If want to set the RS-232 Baud Rate to 9600:

Set to interface window by pressing [MENU], and adjust the
Baud Rate value to 9600 with the wheel knob and press [ENTER]
to complete the setting.

5-6. The Maximum Setting Value

MODEL

ITEM

PSS-3203

PSS-2005

Output Voltage

33.00V

21.00V

Output Current

3.100A

5.200A

Over-voltage

34.00V

22.00V

5-7.Test Lead

MODEL

ITEM

PSS-3203

PSS-2005

Current 3A

Test Lead

Current 4A-10A

Test Lead

5-8. The setting for the GPIB and RS232 Interface

If you have PSS-series programmable power supply, use the GPIB

or RS-232 interface, please refer to the PSS-series Programmer

Manual for more details.

Summary of Contents for PSS-2005

Page 1: ...12 13 13 13 6 MAINTENANCE 6 1 Fuse Replacement 6 2 Line Voltage Conversion 6 3 Adjustment and Calibration 6 4 Cleaning 14 14 14 15 18 7 THE SYSTEM DIAGRAM AND DESCRIPTION 7 1 Block Diagram 7 2 The Ope...

Page 2: ...loured Blue or Black The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red If in doubt consult the instructions provided with the eq...

Page 3: ...0 4 4 1995 Surge Immunity EN 61000 4 5 1995 Conducted Susceptibility EN 61000 4 6 1996 Voltage Dips Interrupts EN 61000 4 11 1994 Safety Low Voltage Directive 73 23 EEC amended by 93 68 EEC IEC EN 610...

Page 4: ...0 21V 1 Voltage 3mV 5mV rating current 3 0A Load Effect Current 3mA 5mA rating current 3 0A Voltage 3mV Source Effect Current 3mA Voltage 10mV Current 1mA 2mA rating current 3 0A Resolution OVP 10mV V...

Page 5: ...ng from the factory Upon receiving the instrument please unpack and inspect it to check if there is any damage caused during transportation If any sign of damage is found notify the bearer and or the...

Page 6: ...32 to 104 F To operate the instrument exceeding this specific temperature range may cause damage to the circuits of instrument Do not use the instrument in a place where strong magnetic or electric f...

Page 7: ...for value input or setting confirmation 8 F C The knob for switching over coarse and fine adjustment 9 MENU The category of function setting Output OVP OCP Contrast Buzzer Interface PS After switching...

Page 8: ...RAMMABLE POWER SUPPLY USER MANUAL 11 Example If want to set the current as 1 234A first using the F C knob to switch the cursor to 1mA step and adjust the value to 34 then switch the cursor to 100mA s...

Page 9: ...indow will be appeared then using the wheel knob to modify the value and press ENTER to complete the setting Note The system will detect the interface used at present automatically and switch the dete...

Page 10: ...tage to another is done by change AC selects switch The rear panel identifies the line voltage to which the unit was factory set To convert to a different line voltage perform the following procedure...

Page 11: ...e Max measured by the DMM with the knob and press ENTER During the current value input use the PSS 3203 2005 PROGRAMMABLE POWER SUPPLY USER MANUAL 17 F C button to switch over the input of 100mA range...

Page 12: ...may leak into the cabinet and cause damage Do not use chemicals containing benzine benzene toluene xylene acetone or similar solvents Do not use abrasive cleaners on any portion of the instrument PSS...

Page 13: ...materials can use the Vr to make adequate adjustment PSS 3203 2005 PROGRAMMABLE POWER SUPPLY USER MANUAL 21 The operation in C C Mode is similar to that in C V Mode The MPU will send 2100 counts 2 1A...

Reviews: